Records from 2024 to 2025. Most recent: inspection, 25 March 2025.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 10 March 2025
Resolved
Fire fighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO observed insuffient water from the emergency fire pump.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 March 2025
Resolution: Received, reviewed and accepted class report from BV stating the deficiency was rectified. Emergency Fire pump was tested and found to be in working order.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 6 February 2025
Resolved
The arrangements of sea connections, fire pumps and their source of power shall be as to ensure that: if a fire in any compartment could put all the pumps out of action, there shall be an alternative means consisting of an emergency fire pump complying with the provision of the Fire Safety Systems Code. Crew could not prove of proper operation of the emergency fire pump. 74 SOLAS (2020) II-2/10.2.2.3.1.2.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 February 2025
Resolution: Received, reviewed and accepted class report from BV stating the deficiency was rectified:
Crew made repairs, RO externally examined and operationally tested vessel's emergency fire pump.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 6 February 2025
Resolved
The maintenance plan shall include at least the following fire protection systems and fire-fighting systems and appliances, where installed: fixed fire detection and fire alarm systems. SOLAS maintenance log book does not address procedures or intervals for fire alarm and detection system testing or maintenance. 74 SOLAS (2020) II-2/2.2.3.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 February 2025
Resolution: Received, reviewed and accepted class report from BV stating the deficiency was rectified.
SOLAS maintenance log book now contains proceedures for the testing and maintenance of fire alarm and detection system
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 February 2025
Resolved
Maintenance, testing and inspections shall be carried out based on guidelines developed by the Organization and in a manner having due regard to ensuring the reliability of fire-fighting systems and appliances. PSCO observed 03 portable fire extinguishers where monthly maintenance had not been conducted.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 February 2025
Resolution: Received, reviewed and accepted class report from BV stating the deficiency was rectified:
All portable extinguishers have been examined to the satisfaction of RO
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 6 February 2025
Resolved
The Safely management system should include procedures ensuring that non-conformities, accidents and hazardous situations are reported to the company, investigated, and analyzed with the objectives of improving safety and pollution prevention. Crew did not report inoperable emergency fire pump in accordance with SMS section 7.1.3.3 (Defect reporting system) 74 SOLAS (2020) IX/3.1 ISM Code 9.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 February 2025
Resolution: Received, reviewed and accepted class report from BV stating the deficiency was rectified:
Crew training addressed reporting of non-conformaties.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Safety and environment policy
Issued 6 February 2025
Resolved
Every company should develop, implement and maintain a safety management system which includes the following functional requirements: instructions and procedures to ensure safe operation of ships. Ships safety procedure plan section 3.14 (Procedures for Lock-out/Tag-out) states that equipment should be physically locked-out. PSCO observed sheet of printer paper over the general service fire pump panel and aux generator # 3 panel stating do not start. 74 SOLAS (2020) IX/3.1 ISM Code Part 1.4.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 February 2025
Resolution: Received, reviewed and accepted class report from BV stating the deficiency was rectified: crew has been trained and ordered to follow SMS procedures.
10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 6 February 2025
Resolved
A copy of the certificate of compliance issued by the testing facility, stating the date of compliance and the applicable performance standards, shall be retained on board the ship. Crew unable to provide a valid certificate of compliance. 74 SOLAS (2020) V/18.8
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 March 2025
Resolved 12 February 2025
Resolution: Received, reviewed and accepted class report from BV stating the deficiency was rectified.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 February 2025
Resolved
No person may cause a vessel to enter into or get underway on the navigable waters of the United States unless the following equipment has been tested: main propulsion machinery, ahead and astern. Chief Engineer stated that power failure tests were not completed. 33 CFR 164.25(a)(5)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 7 February 2025
Resolution: Corrected on the spot.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company verification, review and evaluation
Issued 6 February 2025
No resolution recorded
The company should establish procedures to ensure that the ship in maintained in accordand with the provisions of the relevant rules and regulations established by the company. The technical and/or operational nature of the deficiences 2,3,4,5 provide objective evidence of a serious failure of the implementation of the ISM code. An internal audit report satisfactory to the OCMI must be submitted within 90 days to clear this deficiency. 74 SOLAS (2020) IX/3 ISM Code 10.1
Action required: 705 - Other - as specified
Due 7 May 2025 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 January 2025
Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IS ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA. VESSEL EXPERIENCED MULTIPLE LOSS OF PROPULSION EVENTS WHILE ATTEMPING TO GET UNDERWAY. MANDATORY IN PERSON SURVEY/ATTENDANCE REQUIRED TO CLEAR DEFICIENCY.
SOLAS 74 AS AMENDED 1-11
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 January 2025
Resolution: Deficiency rectified flag and class attended vessel and ran test. Report indicates issue was in a compressed air fitting on the pneumatic valve controlling astern operation of the starting air pilot valve. Valve was disassembled and cleaned.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 26 December 2024
Resolved
The company and the ship shall comply with the requirements of the International Safety Management Code. The technical nature of deficiencies 02, 03, 04, 05, 06, 07, and 08 provide objective evidence of a serious failure, or lack of effectiveness, of the implementation of the ISM Code. Additionally, the vessel failed to notify the flag state and port state, U.S. Coast Guard, of hazardous conditions prior to its inbound transit/berthing—the engine room’s localized fixed fire extinguishing system and two (of three) auxiliary diesel generators were found to be out of service. A safety management audit carried out by the Administration or the RO, with a corresponding report of findings satisfactory to the OCMI must be submitted prior to clearance of this deficiency and release from detention.
74 SOLAS (20) IX / 3.1
30ABC
Action required: 30 - Ship detained
Resolved 24 January 2025
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 26 December 2024
Resolved
2. Means shall be provided to control leaks of flammable liquids.
PSCO observed incredibly excessive oil leaks/splatter, oil-soaked lagging, and quantities of pooled oil in bilges/catchments throughout the entire engine room, especially on/around the fuel oil purifier room, main diesel engine, auxiliary generators 1/2/3, and incinerator room. More than a dozen 55-gallon drums and various sized buckets were found filled with oil and exposed, littered across the engine room. Excessive hydraulic oil leaks were also found on the steering gear and power pack for the aft mooring winch.
74 SOLAS (04) II-2 / 4.2.2
30ABC
Action required: 30 - Ship detained
Resolved 24 January 2025
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 26 December 2024
Resolved
The system should be available for immediate use and capable of continuously supplying water for at least 30 min in order to prevent re-ignition or fire spread within that period of time.
PSCO observed the water mist tank supplying the engine room’s localized fire extinguishing system empty and out of service with hatch cover removed.
FSS CODE (2015) Chapter 7.2.2 (MSC/Circ. 1165 ANNEX 12)
30ABC
Action required: 30 - Ship detained
Resolved 24 January 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 26 December 2024
Resolved
4. A main source of electrical power of sufficient capacity to supply all those services mentioned in regulation 40.1.1 shall be provided. This main source of electrical power shall consist of at least two generating sets.
PSCO observed auxiliary generators 1 & 3 out of service. Auxiliary generator 2, the only generator operational, was found operating with open covers, no insulation on hot spots, and excessive fuel/oil leaks with flywheel valley tray filled with oil.
74 SOLAS (20) II-1 / 41.1.1
30ABC
Action required: 30 - Ship detained
Resolved 24 January 2025
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 26 December 2024
Resolved
5. The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: fire detection and fire alarm systems.
PSCO observed an engine room smoke detector inoperable and covered with a plastic bag. Flame detectors above auxiliary generators 2 & 3 were non-operational when tested.
74 SOLAS (04) II-2 / 14.2.1.1.2
30ABC
Action required: 30 - Ship detained
Resolved 24 January 2025
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 26 December 2024
Resolved
Fire protection systems and fire-fighting systems and appliances shall be maintained ready for use.
PSCO observed the #1 engine room fire pump excessively leaking water and unable to maintain satisfactory pressure. Also, a temporary pipe patch was found on the system with a significant leak into the bilge.
74 SOLAS (04) II-2/ 14.1.1
30ABC
Action required: 30 - Ship detained
Due 24 January 2025
Resolved 24 January 2025
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 26 December 2024
Resolved
Doors required to be self-closing shall not be fitted with holdback hooks. However, hold-back arrangements fitted with remote release devices of the fail-safe type may be utilized.
The self-closing A-0 door between the main engine room and fuel oil purifier room was unable to close properly, and 02 self-closing A-0 doors within the galley/mess deck/scullery were held open with hold back devices.
74 SOLAS (04) II-2/ 9.4.2.2
30AC
Action required: 30 - Ship detained
Resolved 24 January 2025
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 December 2024
Resolved
Ships shall be designed, constructed and maintained in compliance with the structural, mechanical and electrical requirements of a classification society which is recognized by the Administration in accordance with the provisions of regulation XI-1/1, or with applicable national standards of the Administration which provide an equivalent level of safety.
External starboard upper deck accommodation ladder is materially compromised by sheared off bracket pin.
74 SOLAS (20) II-1/3-1
30ABC
Action required: 30 - Ship detained
Resolved 24 January 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 26 December 2024
No resolution recorded
IN ADDITION TO THE REQUIREMENTS CONTAINED ELSEWHERE IN THE PRESENT REGULATIONS, SHIPS SHALL BE DISIGNED, CONSTRUCTED, AND MAINTAINED IN COMPLIANCE WITH THE STRUCTURAL, MECHANICAL AND ELECTRICAL REQUIREMENTS OF A CLASS SOCIETY WHICH IS RECOGNIZED BY THE ADMINISTRATION. VESSEL'S NUMBER 3 GENERATOR IS INOPERABLE VESSEL WAS ISSUED SHORT TERM SAFETY CONSTRUCTION CERTIFICATE BY BV.
74 SOLAS(14)II-1/3-1
40ABC
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 26 December 2024
No resolution recorded
ALL SHIPS OF 10,000 GT AND ABOVE SHALL BE FITTED WITH OIL FILTERING EQUIPMENT TO ENSURE THAT ANY DISCHARGE OF OILY MIXTURES IS AUTOMATICALLY STOPPED WHEN THE OIL CONTENT OF THE EFFLUENT EXEEDS 15 PPM; VESSEL’S OWS IS NOT OPERATIONAL DUE TO A FAULTY OIL CONTENT METER. RO ISSUED SHORT TERM IOPP IN RESPONSE. AS OF 24 JAN 25, VESSEL HAS SUFFICIENT CAPACITY IN BILGE HOLDING TANK TO MAKE INTENDED VOYAGE FROM WILMINGTON, N TO NEW ORLEANS, LA.
MARPOL ANNEX 1/14.7
40ABC
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management System (BMWS)
Issued 26 December 2024
No resolution recorded
THE MASTER, OWNER, OPERATOR, AGENT, OR PERSON IN CHARGE OF A VESSEL EQUIPPED WTIH BALLAST MUST INSTALL AND OPERATE A BALLAST WATER MANAGEMENT SYSTEM THAT IS APPROVED BY THE CG. VESSEL WAS ISSUED CONDITION OF CLASS BY BV.
33CFR 151.2045(a)(1)
40ABC
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 28 March 2024
Resolved
A fixed fire-extinguishing system...may be any of the following systems: a fixed pressure water spraying fire extinguishing system complying with the provisions of the FSS Code. PSCO observed the tank level float of the water tank of the Hyper-Mist system was taped into place. SOLAS 74(09) II-2/10.4.1.1.3, FSS 7.2.1.3, 16ac
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 April 2024
Resolved 4 April 2024
Resolution: Provided class report attesting to the repair of the hyper mist fire system
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boat inventory
Issued 28 March 2024
Resolved
Each survival craft shall be stowed fully equipped as by this chapter and the Code. PSCO observed the first-aid kit missing from the rescue boat. SOLAS 74(20) III/13.1.4, LSA 5.1.2.2, 16ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 April 2024
Resolved 4 April 2024
Resolution: Provided class report attesting to the replacement of the first aid kit.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 28 March 2024
Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. Means shall be provided to control leaks of flammable liquids. PSCO observed excessive oil accumulation on the main engine and steering gear. SOLAS 74(09) II-2/4.1.1, 16ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 April 2024
Resolved 4 April 2024
Resolution: Provided class report attesting to the repair of main engine and steering system to prevent oil leaks.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 March 2024
Resolved
Fire hoses shall be...kept ready for use in conspicuous areas near the water service hydrants or connections. PSCO observed the fire hose in the steering gear room was missing the nozzle. SOLAS 74(09) II-2/10.2.3.1.1, 16ac
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 April 2024
Resolved 4 April 2024
Resolution: Provided class report attesting to the replacement of the nozzle.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Anchoring devices
Issued 28 March 2024
No resolution recorded
The physcal condition of anchors, chains, and cables to ensure that they are free of damage or defects posing safety hazards. The anchor spindle is in an inoperable condition.
33 USC 1223 (b)1, 16ac
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 April 2024 — due date passed with no resolution recorded