OSLO BULK 8 is a 2011 public freight. The Coast Guard has recorded 34 inspections since 2016, most recently in July 2026, along with 10 deficiencies and 5 operational controls.
Records from 2016 to 2026. Most recent: inspection, 13 July 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it8042 - Dead Weight, Metric Ton 11069 - Displacement, Metric Ton 5629 - Convention (Subpart B), Gross Ton 2867 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 34
13 July 2026COE-Dockside
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8432501
26 January 2026PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8299668
6 January 2026Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8289052
29 December 2025Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8288672
23 October 2025In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8257849
23 October 2025In-Service Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8258246
1 October 2025Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8244791
8 July 2025PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8173086
24 June 2025Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8165967
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 October 2025Resolved
THE ADMINISTRATION SHALL BE SATISFIED THAT ADAQUATE ARRANGEMENTS ARE IN PLACE TO ENSURE THAT THE PERFORMANCE OF THE EQUIPMENT REQUIRED BY THIS CHAPTER IS MAINTAINED. PILOT ONBOARD VESSEL NOTIFIED PSCO THAT THE RUDDER ANGLE INDICATOR ON THE BIDGE WAS INOPERABLE WHILE COMPLETING PRE DEPARTURE CHECKS.
74 SOLAS (20) V/16.1
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 24 October 2025
Resolved 24 October 2025
Resolution: Ships crew replaced defective transformer by spare on board. All indicators & dimmers in good working order. Potetentiometer adjusted to correct positions. USCG PSCO & DNV Surveyor verified confirmed wheel commands are showing same angle as required.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 23 October 2025Resolved
SHIPS SHALL BE DESIGNED, CONSTRUCTED AND MAINTAINED IN COMPLIANCE WITH THE STRUCTURAL, MECHANICAL AND ELECTRICAL REQUIREMENTS OF A CLASSIFICATION SOCIETY. PSCO OBSERVED #2 AUXILLARY GENERATOR INOPERABLE.
74 SOLAS (09) 11-1/3-1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 October 2025
Resolved 23 October 2025
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 10 - Deficiency Rectified
Due 23 October 2025
Resolved 23 October 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 23 October 2025Resolved
SHIPS SHALL BE DESIGNED,CONSTRUCTED AND MAINTAINED IN COMPLIANCE WITH THE STRUCTURAL, MECHANICAL AND ELECTRICAL REQUIREMENTS OF A CLASSIFICATION SOCIETY. PSCO OBSERVED #2 AUXILLARY GENERATOR INOPERABLE
74 SOLAS (09) 11-1/3-1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 31 December 2025
Resolved 6 January 2026
Resolution: Sector Mobile observed satisfactory operation of the #2 auxilary generator and reviewed the DNV-GL class survey statement which notes the replacement of the windings within the generator at a shore repair facility.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 19 October 2020Resolved
Ships shall be designed and maintained in compliance with the mechanical requirements of a classification society recognized by the admin in accordance with the provisions of regulation XI-1/1. PSCO noted all four lifting rams on cargo hold number 3 leaking and in need of repair.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 October 2020
Resolved 20 October 2020
Resolution: Verified repaired cargo hold lifting rams operation satisfactory.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 19 October 2020Resolved
An alarm system shall be provided indicating any fault requiring attention and shall be capable of sounding an audible and visual alarm in machinery space. Fire alarm in engine room has audible alarm but visual alarm is not functioning properly
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 October 2020
Resolved 20 October 2020
Resolution: Verified proper operation of visual engine room fire alarm.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 October 2020Resolved
A main source of electrical power of sufficient to supply all those services mentioned in regulation 40.1.1 shall be provided. The main source of electrical power shall consist of at least two generating sets. number on generator has a major coolant leak.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 October 2020
Resolved 20 October 2020
Resolution: Verified proper operation of number one generator with repair made to head gasket.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 October 2020Resolved
Electrical installations shall be such that the safety of passengers and crew and ship from electrical hazards will be ensured. Addition of unauthorized electrical connection the emergency switchboard breaker.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 20 October 2020
Resolved 20 October 2020
Resolution: Unauthorized connection was removed from emergency generator switchboard.
09 - Working and Living Conditions › 092 - Working Conditions › Heating
Issued 19 October 2020Resolved
The machinery, boilers, and other pressure vessels, associated pipping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. PSCO noted water leak in steam piping above main engine at flange with lagging removed.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 October 2020
Resolved 20 October 2020
Resolution: Verified proper repair was completed on steam piping above main engine.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 12 March 2018Resolved
02 self lighting lights were non-operational.
Action required: 10 - Deficiency Rectified
Resolved 12 March 2018
Resolution: PSCOs witnessed the electrician change the bulbs.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.