MAURY USCG vessel records
← All vessels

OSLO BULK 8

OSLO BULK 8 is a 2011 public freight. The Coast Guard has recorded 34 inspections since 2016, most recently in July 2026, along with 10 deficiencies and 5 operational controls.

Records from 2016 to 2026. Most recent: inspection, 13 July 2026.

Built
2011
Last inspected
13 July 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 13 July 2026
…with no type recorded5
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9485813
CQ2474
1142087
Flag
PORTUGAL
Maury page id
psix-1142087

Documentation record

Tonnage as PSIX records it8042 - Dead Weight, Metric Ton
11069 - Displacement, Metric Ton
5629 - Convention (Subpart B), Gross Ton
2867 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 34

13 July 2026 COE-Dockside
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8432501
26 January 2026 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8299668
6 January 2026 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8289052
29 December 2025 Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8288672
23 October 2025 In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8257849
23 October 2025 In-Service Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8258246
1 October 2025 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8244791
8 July 2025 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8173086
24 June 2025 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8165967
23 June 2025 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8165273
7 May 2025 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8130578
7 December 2023 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7833209
4 December 2023 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7833521
23 August 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7541581
10 May 2022 PSC B
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7445372
6 May 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7445400
29 December 2021 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7373506
19 October 2020 PSC B · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7075669
25 March 2020 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6931504
18 October 2019 ISPS II Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6834188
5 April 2019 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6647806
4 December 2018 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6592147
11 September 2018 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6538716
5 September 2018 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6532714
12 March 2018 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6366256
15 November 2017 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6307457
9 November 2017 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6303898
3 September 2017 Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6258130
27 April 2017 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6133704
18 March 2017 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6107003
8 March 2017 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6100938
2 June 2016 Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5895484
18 February 2016 COE-Dockside · Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5817966
16 February 2016 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5816164

Deficiency record · 10

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 October 2025 Resolved
THE ADMINISTRATION SHALL BE SATISFIED THAT ADAQUATE ARRANGEMENTS ARE IN PLACE TO ENSURE THAT THE PERFORMANCE OF THE EQUIPMENT REQUIRED BY THIS CHAPTER IS MAINTAINED. PILOT ONBOARD VESSEL NOTIFIED PSCO THAT THE RUDDER ANGLE INDICATOR ON THE BIDGE WAS INOPERABLE WHILE COMPLETING PRE DEPARTURE CHECKS. 74 SOLAS (20) V/16.1
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 24 October 2025
Resolved 24 October 2025
Resolution: Ships crew replaced defective transformer by spare on board. All indicators & dimmers in good working order. Potetentiometer adjusted to correct positions. USCG PSCO & DNV Surveyor verified confirmed wheel commands are showing same angle as required.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 23 October 2025 Resolved
SHIPS SHALL BE DESIGNED, CONSTRUCTED AND MAINTAINED IN COMPLIANCE WITH THE STRUCTURAL, MECHANICAL AND ELECTRICAL REQUIREMENTS OF A CLASSIFICATION SOCIETY. PSCO OBSERVED #2 AUXILLARY GENERATOR INOPERABLE. 74 SOLAS (09) 11-1/3-1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 October 2025
Resolved 23 October 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 23 October 2025 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 10 - Deficiency Rectified
Due 23 October 2025
Resolved 23 October 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 23 October 2025 Resolved
SHIPS SHALL BE DESIGNED,CONSTRUCTED AND MAINTAINED IN COMPLIANCE WITH THE STRUCTURAL, MECHANICAL AND ELECTRICAL REQUIREMENTS OF A CLASSIFICATION SOCIETY. PSCO OBSERVED #2 AUXILLARY GENERATOR INOPERABLE 74 SOLAS (09) 11-1/3-1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 31 December 2025
Resolved 6 January 2026
Resolution: Sector Mobile observed satisfactory operation of the #2 auxilary generator and reviewed the DNV-GL class survey statement which notes the replacement of the windings within the generator at a shore repair facility.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 19 October 2020 Resolved
Ships shall be designed and maintained in compliance with the mechanical requirements of a classification society recognized by the admin in accordance with the provisions of regulation XI-1/1. PSCO noted all four lifting rams on cargo hold number 3 leaking and in need of repair.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 October 2020
Resolved 20 October 2020
Resolution: Verified repaired cargo hold lifting rams operation satisfactory.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 19 October 2020 Resolved
An alarm system shall be provided indicating any fault requiring attention and shall be capable of sounding an audible and visual alarm in machinery space. Fire alarm in engine room has audible alarm but visual alarm is not functioning properly
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 October 2020
Resolved 20 October 2020
Resolution: Verified proper operation of visual engine room fire alarm.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 October 2020 Resolved
A main source of electrical power of sufficient to supply all those services mentioned in regulation 40.1.1 shall be provided. The main source of electrical power shall consist of at least two generating sets. number on generator has a major coolant leak.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 October 2020
Resolved 20 October 2020
Resolution: Verified proper operation of number one generator with repair made to head gasket.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 October 2020 Resolved
Electrical installations shall be such that the safety of passengers and crew and ship from electrical hazards will be ensured. Addition of unauthorized electrical connection the emergency switchboard breaker.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 20 October 2020
Resolved 20 October 2020
Resolution: Unauthorized connection was removed from emergency generator switchboard.
09 - Working and Living Conditions › 092 - Working Conditions › Heating
Issued 19 October 2020 Resolved
The machinery, boilers, and other pressure vessels, associated pipping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. PSCO noted water leak in steam piping above main engine at flange with lagging removed.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 October 2020
Resolved 20 October 2020
Resolution: Verified proper repair was completed on steam piping above main engine.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 12 March 2018 Resolved
02 self lighting lights were non-operational.
Action required: 10 - Deficiency Rectified
Resolved 12 March 2018
Resolution: PSCOs witnessed the electrician change the bulbs.

Ownership record