← All vessels
SCOT MUNCHEN
SCOT MUNCHEN is a 2013 tank ship. The Coast Guard has recorded 9 inspections since 2017, most recently in December 2025, along with 4 deficiencies and 3 operational controls.
Records from 2017 to 2025. Most recent: inspection, 16 December 2025.
- Built
- 2013
- Last inspected
- 16 December 2025
- Documentation
- Not in the documentation file of 10 August 2026
- Deficiencies
- 4 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9255816
9HA4098
1142335
Flag
MALTA
Maury page id
psix-1142335
Inspections, by type
…with no type recorded3
Years with a record
5 calendar years (2017–2025)
The 9 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Documentation record
Tonnage as PSIX records it5145 - Convention (Subpart B), Gross Ton
8266 - Dead Weight, Metric Ton
11614 - Displacement, Metric Ton
2532 - Convention (Subpart B), Net Ton
8266 - Dead Weight, Metric Ton
11614 - Displacement, Metric Ton
2532 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.
Inspection history · 9
16 December 2025
PSC B · COE-Dockside · COC-CHEM & TVE Renew
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8283394
3 July 2020
PSC B · COC-CHEM & TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6994278
20 June 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6719836
19 December 2018
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6600198
2 December 2018
COC-CHEM & TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6590083
29 November 2018
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6589396
4 February 2018
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6349081
4 September 2017
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6259360
3 March 2017
ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6096518
Deficiency record · 4
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 2 December 2018
Resolved
Flexible pipes and end attachments shall be of approved fire resting materials. The return fuel-oil flexible hose on the starboard side main generator is not type approved and is not fire-resistant. SOLAS 01 11-2/4.2.2.5.1. 40a
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 2 December 2018
Resolved
Independent cargo tanks and gasketed cargo pipe joints shall be electrically bonded to the hull. The vessel's cargo deck wiring and connections was found not to be bonded due to cuts, corrosion, and missing sections.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 2 December 2018
Resolved
Termination and joints in all conductors shall be so made as to retain the original electrical, mechanical flame retarding, and, where necessary, fire resisting properties of the cable. Dead-End wiring was found throughout the deck area associated with the cargo pump valve indicators.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 3 March 2017
Resolved
1499-Other-Piping shall be of a design and construction adequate for service and installed to minimize any danger to persons onboard. PSCO observed exhaust leaking from the emergency generator exhaust pipe. Crew repaired on the spot 74SOLAS(14) II-1/26.1
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.