MAURY USCG vessel records
← All vessels

CARIBBEAN STAR

CARIBBEAN STAR is a 2008 freight ship. The Coast Guard has recorded 43 inspections since 2016, most recently in July 2026, along with 11 deficiencies and 9 operational controls.

Records from 2016 to 2026. Most recent: inspection, 1 July 2026.

Built
2008
Last inspected
1 July 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 1 July 2026
…with no type recorded18
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9395135
1142472
Flag
CYPRUS
Maury page id
psix-1142472

Documentation record

Tonnage as PSIX records it15375 - Convention (Subpart B), Gross Ton
5983 - Convention (Subpart B), Net Ton
18464 - Dead Weight, Metric Ton
25252 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 43

1 July 2026 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8421131
5 June 2026 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8391422
4 June 2025 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8151971
3 June 2025 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8150807
21 May 2025 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8140528
4 October 2023 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7801282
22 August 2023 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7774077
10 May 2023 Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7685139
19 April 2023 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7671954
6 April 2023 Deficiency Check · PSC B · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7663244
6 October 2022 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7572557
20 September 2022 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7561222
9 September 2021 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7308469
7 September 2021 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7306003
26 August 2021 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7296021
8 March 2021 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7152036
24 February 2021 PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7144699
12 January 2021 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7123258
11 August 2020 PSC B · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7029559
11 March 2020 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6923180
18 January 2020 PSC B · Ballast Water Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6891958
14 March 2019 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6642563
6 March 2019 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6637658
3 March 2019 ISPS II Exam · PI Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6634640
28 February 2019 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6634032
28 February 2019 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6634383
25 February 2019 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6631713
11 February 2019 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6623462
28 January 2019 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6615775
14 January 2019 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6609784
18 December 2018 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6599488
19 November 2018 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6583502
9 October 2018 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6557372
14 March 2018 Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6371832
1 March 2018 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6363789
16 February 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6356143
4 November 2017 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6300630
15 September 2017 ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6265339
17 August 2017 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6243289
11 August 2017 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6237242
19 December 2016 In-Service Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6059989
19 December 2016 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6060181
25 November 2016 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6047376

Deficiency record · 11

14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management System (BMWS)
Issued 1 July 2026 Resolved
The master, owner, operator, agent or person in charge of a vessel subjet to this subpart and this section must submit a ballast water report to the National Ballast Information Clearinghouse (NBIC) by electronic ballast watre report format using methods specified at NBIC's website... The vessel has not submitted any NBIC reports since January 2026 despite conducting operations in U.S. ports multiple times between January 2026 and today. 33 CFR 151.2060 10c
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 1 July 2026
Resolved 1 July 2026
Resolution: Deficiency cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 6 April 2023 Resolved
BEFORE THE SHIP LEAVES PORT AND AT ALL TIMES DURING THE VOYAGE, ALL LIFE-SAVING APPLIANCES SHALL BE IN WORKING ORDER AND READY FOR IMMEDIATE USE. PSCO'S OBSERVED INOPERABLE THROTTLE CABLE SERVING THE OUTBOARD ENGINE FOR THE RESCUE BOAT, RENDERING THE RESCUE BOAT ENGINE NOT READY FOR IMMEDIATE USE 74SOLAS(20CONS.) III/20.2
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2023
Resolved 20 April 2023
Resolution: Two throttle cables serving the outboard engine were replaced with the same model and characteristics as original. The engine rescue boat was tested in presence of attending surveyor, resulting satisfactory.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 24 February 2021 Resolved
Efficient guard rails or bulwarks shall be fitted to all exposed parts of the freeboard and superstructure decks. Handrails forward of superstructure spanning multiple decks running the length of the beam are severely wasted and/or detached. ICLL 66/88 ANNEX I/Reg. 25(2)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 8 March 2021
Resolution: See attached DNV-GL Survey Statement.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 February 2021 Resolved
All life-saving appliances and arrangements shall comply with applicable requirements of the Code. Every lifebuoy shall be fitted with a grab line... not less than four times the outside diameter of the body of the buoy in length. Multiple lifebuoys onboard had grab line that did not meet required length. 74SOLAS(14)III/34 LSA Code 2.1.1.8
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2021
Resolved 8 March 2021
Resolution: See attached DNV-GL Survey Statement.
10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 11 August 2020 Resolved
To assist in casualty investigations, ships, when engaged on international voyages...shall be fitted with a Voyage Data Recorder (VDR) as follows.. PSCO observed error messages dated 8/8/2020 stating that the VDR was unable to record data to the float-free capsule as required by resolution A.861(20). Crew was able to reboot the system as instructed by manufacturer's manual. VDR error messages were cleared as indicated by the manual. 74 SOLAS (14 CONS) CH. V/20.1
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2020
Resolved 20 August 2020
Resolution: Vessel sent class report attesting to proper operation of VDR.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 August 2020 Resolved
...Fixed fire detection and fire alarm system installations shall be suitable for the nature of the space. During exam PSCO found unauthorized welding equipment and flammables inside of the forward storage. Crew explained that the space is used as a welding workshop. There is no fixed fire detection or suppression in the space. 74 SOLAS (14 CONS) CH. II-2/7.1.1
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 11 August 2020
Resolved 11 August 2020
Resolution: Acetylene and Oxygen bottle installation removed. Flammables removed from space in the presence of PSCO's.
02 - Structural Conditions › N/A - No Subsystem › Openings to cargo area, doors, ... scuttles
Issued 11 August 2020 Resolved
All access openings in bulkheads at ends of enclosed superstructures shall be fitted with doors of steel... and weathertight when closed. The frame for the paint locker's door has wasted to form a hole. ICLL 66 Annex I/12.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 August 2020
Resolved 20 August 2020
Resolution: Door Steel Welded to maintain Fire Boundary as surveyed and attested by DNVGL 20AUG20 Job ID 1492132 received and reviewed by FFVE
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 3 March 2019 Resolved
A self-contained emergency source of electrical power shall be provided. Emergency diesel generator module is currently inoperable and unable to produce emergency source of electrical power to the ship - 74 SOLAS (2004) II-1/43.1 - 17BC
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 March 2019
Resolution: PSCO received Class and Flag documentation attesting to the rectification of Emergency Generator deficiency.
Engineering › Lubricating Oil Service System › Pump
Issued 1 March 2018 Resolved
9800 - THE PURPOSE OF THIS REGULATION IS TO PREVENT THE IGNITION OF COMBUSTABLE MATERIALS OR FLAMMABLE LIQUIDS. A MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS / #1 GENERATOR PUMP WAS OBSERVED LEAKING. 74SOLAS(14) ii-2/4.1.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 1 March 2018
Resolved 13 March 2018
Resolution: DNV GL conducted a survey and witnessed the #1 generator running with no leaks after the lube oil pump was replaced.
Construction/Loadline › Structures › Superstructure
Issued 1 March 2018 Resolved
1299 - GUARD RAILS FITTED IN THE FREEBOARD DECKS SHALL HAVE ATLEAST THREE COURSES. / BOTTOM RAIL WAS MISSING ON PORT SIDE RAILING - ICLL(88) REG 25.3
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 1 March 2018
Resolved 13 March 2018
Resolution: DNV GL conducted a survey and verified the correct installation of the missing lower course of the hand rails.
Electrical › Electric Generation Source (emergency) › Generator
Issued 1 March 2018 Resolved
1499 - THE ELECTRICAL POWER AVAILABLE SHALL BE SUFFICIENT TO SUPPLY ALL THOSE SERVICES THST ARE ESSENTIAL FOR SAFETY IN AN EMERGENCY FOR A SPECIFIED PERIOD OF TIME, / EMERGENCY GENERATOR FUEL TANK WAS OBSERVED WITH INSUFFICENT FUEL LEVEL. 74 SOLAS(14) ii-1/43.2
Action required: 705 - Other - as specified
Due 1 March 2018
Resolved 1 March 2018

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.