Records from 2016 to 2025. Most recent: inspection, 16 September 2025.
Inspection history · 6
16 September 2025
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8235463
13 August 2025
PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8192764
31 March 2021
PSC B
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7160733
18 April 2019
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6654449
31 May 2017
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6161161
7 February 2016
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5806753
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 13 August 2025
Resolved
In Lifeboat annual servicing report date 25JUN25 the follow up block required several items that were not addressed: "PORT AND STBD FWD GRIPE BOLLARD FOUND EXCESSIVE CORRODED, PLEASE REPLACE."
"PORT AND STBD LASHING LINE REPLACEMENT IS RECOMMENDED."
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 September 2025
Resolved 11 September 2025
Resolution: Lashing line replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 13 August 2025
Resolved
03 food rations in each lifeboat found not airtight and require replacement.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 September 2025
Resolved 11 September 2025
Resolution: Rations replaced.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 13 August 2025
Resolved
During the fire drill PSCO observed the following:
1. crew muster was held directly outside the paint locker
2. The two firefighters dressed out in the firefighting equipment that entered the paint locker had no means to fight the fire(fire hose, extinguishers).
Action required: 10 - Deficiency Rectified
Due 13 August 2025
Resolved 13 August 2025
Resolution: Second fire drill was carried out satisfatorily with PSCO in attendance.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 31 March 2021
Resolved
BEFORE THE SHIP LEAVES PORT AND AT ALL TIMES DURING THE VOYAGE, ALL LIFE-SAVING APPLIANCES SHALL BE IN WPRKING ORDER AND READY FOR IMMEDIATE USE. PSCO DISCOVERED INOPERABLE ZIPPERS ON 02 IMMERSION SUITS.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 March 2021
Resolved 5 April 2021
Resolution: Vessel provided documentation and photographs showing receipt of new immersion suits.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 31 May 2017
Resolved
0660 - All life-saving appliances and arrangements shall comply with the applicable requirements of the code. The method of securing the wearer must have quick and positive means of closure that do not require tying of knota. PSCO observed life jackets that required tying of knots. 74SOLAS(14)III/34. LSA Code 2.2.1.5.4
Condition: Invalid
Due 14 June 2017
Resolved 25 June 2017
Resolution: Vessel received new life jackets on board that do not exclusively require tying.