MAURY USCG vessel records Sign in
← All vessels

MAERSK WILLEMSTADT

MAERSK WILLEMSTADT is a 2007 freight ship. The Coast Guard has recorded 27 inspections since 2011, most recently in April 2026, along with 7 deficiencies and 5 operational controls.

Records from 2011 to 2026. Most recent: inspection, 17 April 2026.

Built
2007
Last inspected
17 April 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9362401 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9V7729
1142689
Flag
SINGAPORE
—
Maury page id
psix-1142689

Inspections, by type

…with no type recorded4
Years with a record 11 calendar years (2011–2026)
The 27 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it41483 - Convention (Subpart B), Gross Ton
23894 - Convention (Subpart B), Net Ton
53093 - Dead Weight, Ton
69348 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 27

17 April 2026 PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8350634
27 January 2026 In-Service Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8302414
29 August 2025 PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8218225
10 June 2025 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8156374
22 March 2025 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8097849
7 November 2024 Administrative Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8031824
7 November 2024 Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8037992
26 October 2024 PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8024968
22 October 2024 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8023142
3 May 2024 PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7903096
3 November 2023 PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7818574
20 March 2023 PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7652852
18 July 2022 PSC B · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7510491
14 January 2022 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7380616
3 March 2021 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7150087
3 March 2021 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7152259
5 April 2019 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6655017
13 April 2018 Administrative Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6390959
3 April 2018 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6383915
15 March 2017 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6105082
29 March 2016 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5842657
22 January 2016 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5800380
21 January 2016 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5801422
16 January 2016 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5798667
23 August 2011 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4125441
8 August 2011 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4108896
7 August 2011 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4104934

Deficiency record · 7

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 January 2026 Resolved
The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. PSCO was notified that ME unit 5 fuel pump malfunctioned and consequently ME unit 5 cylinder was locked out. 74 SOLAS(04)II-1/26.1 17a.c.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 January 2026
Resolution: Received Class LR report attesting cylinder 5 fully functional.
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 26 October 2024 Resolved
A low-level alarm for each hydraulic fluidreservoir to give the earliest practicable indication of hydraulic fluid leakage. Audible and visual alarms shall be given on the navigational bridge and in machinery space. PSCO observed no audible alarm from the #1 and #2 steering pump on the bridge.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 26 October 2024
Resolved 7 November 2024
Resolution: Vessel provided Class documentation attesting to the replacement and proper operation of the NAV bridges steering low level audio alarm (see attached in documents).
Construction/Loadline › Markings › Load Line Mark
Issued 3 April 2018 Resolved
1220 - FREEBOARD MARK - THE DECK LINE IS A HORIZONTAL LINE 300 MM IN LENGTH AND 25MM IN BREADTH. IT SHALL BE MARKED AMIDSHIPS ON EACH SIDE OF THE SHIP. THERE WAS NO DECK LINE ON THE PORT SIDE OF THE VESSEL.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 April 2018
Resolution: Vessel sent in documentation from class clearing the def. See attached email.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 22 January 2016 Resolved
Doors required to be self closing shall not be fitted with hold back hooks. Several doors fitted with hold back hooks thoughout the ship. 74SOLAS(14) II-2/9.4.2.2 10C
Action required: 705 - Other - as specified
Due 22 January 2016
Resolved 22 January 2016
Resolution: Hold back hooks were removed.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 22 January 2016 Resolved
Electrical installations shall be such that electrical services essential for safety will be ensured under various emergency conditions. PSCO found 09 emergency light bulbs inoperative. 74SOLAS (14) II-I/ 40.1.2 10C
Due 22 January 2016
Resolved 22 January 2016
Resolution: Bulbs were replaced.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 8 August 2011 Resolved
Vessel is currently non compliant with class approved Fire Control Plan. Ship Office, Captain's Office, Outer Doors on Upper Deck, Engine and Deck Changing Rooms, and galley doors currently held open by hooks. Fire Control Plan currently shows self closing doors. SOLAS REG 15 2.4
Action required: 705 - Other - as specified
Due 15 August 2011
Resolved 25 August 2011
Resolution: Vessel submitted Class Report attesting door hooks have been removed and that vessel is currently compliant with its fire control plan. Class Report scanned into documents.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 8 August 2011 Resolved
Vessel has cut out railing aft on starboard side.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 August 2011
Resolved 25 August 2011
Resolution: Railing reinstalled and inspected to the satisfaction of attending Class surveyor.

Ownership record