MICHAEL LAWRENCE is a 2012 offshore supply vessel. The Coast Guard has recorded 6 inspections since 2016, most recently in November 2018, along with 1 deficiency.
Records from 2016 to 2018. Most recent: inspection, 16 November 2018.
This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it91 - Regulatory (Subpart C or D), Gross Ton 468 - Convention (Subpart B), Gross Ton 62 - Regulatory (Subpart C or D), Net Ton 140 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 6
16 November 2018In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6582198
7 May 2018Annual Survey · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6408050
27 April 2017Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6134197
18 May 2016COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5880114
Electrical › Electric Generation Source (service) › Power Requirement
Issued 18 May 2016Resolved
Number one generator failed to take a load and would stall when applied.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 May 2016
Resolution: [name withheld] witnessed satisfactory test of generator sustaining ships load. Service tech had determined bad ECM to be cause of failure. All sat.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.