Records from 2016 to 2026. Most recent: inspection, 23 June 2026.
Inspection history · 18
23 June 2026
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8403373
3 February 2026
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8305308
1 December 2025
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8271811
2 October 2025
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8245696
2 October 2025
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8246203
11 April 2024
PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7865499
16 September 2022
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7560341
25 May 2018
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6423607
23 May 2018
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6412572
18 May 2018
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6417953
18 February 2018
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6357033
15 December 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6058377
15 December 2016
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6059884
9 May 2016
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5872359
21 January 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5801044
21 January 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5881833
18 January 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5799072
18 January 2016
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5799199
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 23 June 2026
Resolved
The machinary, boilers and other pressure vessels, associated piping systmes, and fittings shall be of a design and construction adequate for the service for which they are intended. PSCO observed fluid overflow on the emergency generator. Chief engineer stated it was coolant. 74 SOLAS (cons) II-1/26/1, 60ac.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 23 June 2026
Resolved 24 June 2026
Resolution: Recieved, reviewed, and accepted class report. See documents for details.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 23 June 2026
Resolved
An immersion suit complying with the requirements of section 2.3 of the Code...shall be provided for every person. PSCO observed immersion suit zipper inoperable from wear. 74 SOLAS (cons.) III/7.3, 10c.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 23 June 2026
Resolved 23 June 2026
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 9 May 2016
Resolved
0740-Pumps. Emergency fire pump failed to produce pressure and installed priming system was activly leaking filling the void compartment the pump was located in with water. SOLAS II-2/10.10.1.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 May 2016
Resolved 19 May 2016
Resolution: Recieved ABS class report and Liberian Flag Dispensation letter allowing vessel to operate with only two operational fire pumps. ABS issued tempoarary Cargo Ships Safety Equipment Certificate experation 30JUN2016.
Fire Fighting › Fire Pumps › Pumpshaft
Issued 9 May 2016
Resolved
0740-Pumps. Both primary #1 and #2 Fire pumps had excessive water leakage around the mechanical shaft seals with the pump was not operational. Leakage of water was enough to fill the bilge void flooding alarm, causing crew to leave the alarm in cut out mode. SOLAS II-1 c.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 May 2016
Resolved 18 May 2016
Resolution: Recieved ABS class report and Liberian Flag Dispensation letter allowing vessel to operate with only two operational fire pumps. ABS issued tempoarary Cargo Ships Safety Equipment Certificate experation 30JUN2016.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 9 May 2016
Resolved
0750 - Fire Prevention. Fire doors surrounding the galley were equipt with mechanical hold backs preventing the closure in the event of a fire. Door to the dry provisions was included in this which was rated A-0 Bulkhead. SOLAS II-2/9.4.2.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2016
Resolved 19 May 2016
Resolution: Recieved ABS class report and Liberian Flag Dispensation letter allowing vessel to operate with only two operational fire pumps. ABS issued tempoarary Cargo Ships Safety Equipment Certificate experation 30JUN2016.
Engineering › Diesel Engine (propulsion-direct drive) › Injector (fuel injection)
Issued 9 May 2016
Resolved
1410-Propulsion Main Engine. External high pressure fuel lines shall be protected with double jacketed systems capable of containing a fuelline failure. PSCO's noted four loose fuel fittings. SOLAS (14) II-2/4.2.2.5.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 18 May 2016
Resolution: Crew Tightened loose fuel fitting while exam team was still on vessel.