MAURY USCG vessel records Sign in
← All vessels

BARONESS

BARONESS is a 2011 freight ship. The Coast Guard has recorded 9 inspections since 2011, most recently in January 2024, along with 4 deficiencies and 1 operational control.

Records from 2011 to 2024. Most recent: inspection, 29 January 2024.

Built
2011
Last inspected
29 January 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9588407 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1144850
Flag
PANAMA
—
Maury page id
psix-1144850

Inspections, by type

…with no type recorded1
Years with a record 7 calendar years (2011–2024)
The 9 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it34264 - Dead Weight, Metric Ton
44759 - Displacement, Metric Ton
22137 - Convention (Subpart B), Gross Ton
11328 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 9

29 January 2024 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7857357
30 March 2023 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7659907
4 November 2017 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6300600
11 November 2016 Ballast Water Examination · ISPS II Exam · NPV Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6034878
12 April 2016 PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5852836
7 April 2016 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5849327
11 June 2014 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4886068
4 July 2012 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4350882
15 August 2011 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4110357

Deficiency record · 4

07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 30 March 2023 Resolved
Door fitted in boundary bulkheads of machinery spaces of category A shall be reasonably gastight and self-closing. PSCOs observed 02 Class A doors not being able to self close. SOLAS 74 (04) II-2/9.4.2.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 3 April 2023
Resolved 29 January 2024
Resolution: 29JAN2024: Deficiency has been cleared but the resolution box was not completed.
Engineering › Bilge Water Management System › Not Operational
Issued 4 November 2017 Resolved
10c-1440- Bilge wells...shall be locaated and monitored in such a way that the accumulation of liquids is detected at normal angles. PSCO observed bilge alarms were not working as designed (2 of 3). 74SOLAS (2004 cons.) II-I/26.1
Due 4 November 2017
Resolved 4 November 2017
Personnel › Training › Familiarization Training
Issued 4 November 2017 Resolved
10c-1730- Ship staff training must include familiartization in the operation and maintenance of the equipment. Ship staff was slow (approximately 1 hour) to test OWS. 33CFR155.380
Due 4 November 2017
Resolved 4 November 2017
Operations/Management › Pollution › Retention of Oily Mixture
Issued 4 November 2017 Resolved
17c-1420- The machinery, boilers and other pressure vessels, associated piping systems and fittings...shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being part to moving parts, hot surfaces, and other hazards. PSCO observed build up of oily water at a high level in bilge, and oil in the fuel oil purifier room and under the auxiliary engine. Build up of oil poses a fire threat to vessel. 74SOLAS (2004 cons.)II-1/26.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 November 2017
Resolution: PSCO observed significant cleaning of ENG Room. Vessel contracted third party to assist with excessive oil in the engine room.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.