Records from 1993 to 2019. Most recent: inspection, 24 February 2019.
Inspection history · 30
24 February 2019
Type not recorded
No type recorded · USCGC CUTTYHUNK (WPB 1322) · USCG Northwest District (CGD-NW) · Activity 6635929
25 June 2014
Type not recorded
No type recorded · Station Cape Disappointment · USCG Northwest District (CGD-NW) · Activity 4899973
25 June 2014
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4907470
16 March 2014
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4817905
31 January 2012
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4240314
24 March 2010
Type not recorded
No type recorded · Station Grays Harbor · USCG Northwest District (CGD-NW) · Activity 3703311
24 March 2010
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3710339
27 July 2009
Examination of Repairs
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3547953
18 July 2009
Type not recorded
No type recorded · Station Cape Disappointment · USCG Northwest District (CGD-NW) · Activity 3538488
17 July 2009
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3537935
17 July 2009
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3610856
10 July 2009
Type not recorded
No type recorded · Station Cape Disappointment · USCG Northwest District (CGD-NW) · Activity 3531977
10 July 2009
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3610449
1 July 2009
Deficiency Check · Hull Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3521303
9 July 2008
COI Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3260660
12 December 2007
Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3114593
20 September 2007
Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3060859
2 May 2007
Deficiency Check · Hull Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2920574
28 September 2006
Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2781489
26 April 2006
Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2632449
23 September 2005
Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2503166
2 May 2005
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2347390
20 April 2005
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2323763
15 June 2004
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2093814
5 May 2004
Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2056260
1 July 2003
Initial Certification · Hull Examination · Plan Review "T" Boat
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1772081
21 December 2001
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1482768
5 September 2001
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 120169
2 September 1997
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 120457
28 June 1993
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 53772
Electrical › Electrical Distribution System (service) › Cable
Issued 27 July 2009
Resolved
Remove unauthorized shore type cables (direct burial cables in the engine compartment) with approved boat cables as needed, prior to the carriage of passengers for hire and prior to completion of annual inspection. (Vessel is only operating as a commercial fishing vessel at this time).
Due 9 October 2009
Resolved 3 March 2011
Engineering › Fuel Oil Service System › Filter
Issued 1 July 2009
Resolved
Install flame shield heat reflector bowls on aux generator. Vessel is currently only operating as an uninspected commercial fishing vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 October 2009
Resolved 3 March 2011
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 1 July 2009
Resolved
Provide access to shaft compartments beneath fish hold for shafting inspection. Vessel is currently only operating as an uninspected commercial fishing vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 October 2009
Resolved 3 March 2011
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 9 July 2008
Resolved
Renew saltwater cooling supply hose for the aux generator, prior to the completion of next credit drydock. Owner intends to improve upon installation design.
Due 1 June 2009
Resolved 1 July 2009
Navigation › Piloting/Steering › Marine Charts
Issued 9 July 2008
Resolved
Provide current navigation chart #18003.
Due 12 July 2008
Resolved 9 July 2008
Documentation › Logs/Records › Drug Test Records
Issued 20 September 2007
Resolved
Provide proof of current drug and alcohol testing program enrollment, prior to the carriage of passengers.
Due 1 December 2007
Resolved 12 December 2007
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 20 September 2007
Resolved
Prove operation of navigation lights, prior to the carriage of passengers for hire.
Due 1 December 2007
Resolved 12 December 2007
Communications › Alarms/Indicators › Bilge Alarm
Issued 20 September 2007
Resolved
Prove operation of engine room bilge alarm, prior to the carriage of passengers.
Due 1 December 2007
Resolved 20 September 2007
Navigation › Piloting/Steering › US Coast Pilot
Issued 20 September 2007
Resolved
Provide current U.S. Coast Pilot [name withheld] and Tidal Current Tables, prior to the carriage of passengers.
Due 1 December 2007
Resolved 12 December 2007
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 20 September 2007
Resolved
Provide eye wash for first aid kit, prior to the carriage of passengers.
Due 1 December 2007
Resolved 12 December 2007
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 28 September 2006
Resolved
Renew or hydrostatically test the B-II fire extinguisher that is located outside on the aft bulkhead for the deck house. Correct prior to carriage of passengers and prior to April 2007 required drydock.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 May 2007
Resolution: renewed
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 28 September 2006
Resolved
Repair or renew stbd side railing to meet 46 CFR 177.900(b). Correct prior to carriage of passengers and prior to April 2007 required drydock.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 May 2007
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 28 September 2006
Resolved
Replace or fabricate new protective cover to fit over electrical terminal blocks in engine room stbd side. Correct prior to carriage of passengers and prior to April 2007 required drydock.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 May 2007
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 28 September 2006
Resolved
Install a plug or cap for piping for engine coolant where was connected to block heater. Correct prior to carriage of passengers and prior to April 2007 required drydock.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 May 2007
Documentation › Certificates/Documents › Stability Letter
Issued 23 September 2005
Resolved
Post stability letter at operating station, prior to the carriage of passengers.
Due 15 April 2006
Resolved 26 April 2006
Operations/Management › Pollution › Control of Discharge of Oil
Issued 23 September 2005
Resolved
Remove oil from engine room bilges, prior to the carriage of passengers.
Due 15 April 2006
Resolved 26 April 2006
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 23 September 2005
Resolved
Remove water, identify source of water in the engine room portside outboard frame bay, prior to the carriage of passengers.
Due 15 April 2006
Resolved 26 April 2006
Electrical › Electric Generation Source (service) › Generator
Issued 23 September 2005
Resolved
Clean, remove oil from generator windings and fan, prior to the carriage of passengers.
Due 15 April 2006
Resolved 26 April 2006
Fire Fighting › Fixed CO2 Fire Extinguishing System › Automatic Heat Detectors
Issued 23 September 2005
Resolved
Prove operation of engine room heat sensor, prior to the carriage of passengers.
Due 15 April 2006
Resolved 26 April 2006
Documentation › Markings/Placards › Warning Signs
Issued 23 September 2005
Resolved
Label CO2 room to identify location, visible independent of whether the door is open or closed, prior to the carriage of passengers.
Due 15 April 2006
Resolved 26 April 2006
Fire Fighting › Fire Bucket › Lanyard
Issued 23 September 2005
Resolved
Provide lanyards and label 03 fire buckets, prior to the carriage of passengers.
Due 15 April 2006
Resolved 26 April 2006
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 20 April 2005
Resolved
Install courses at no greater than 12 inches on all deck rails, prior to the carriage of passengers.
Due 20 May 2005
Resolved 2 May 2005
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 20 April 2005
Resolved
Provide proof of annual service for fixed CO2 and portable fire extinguishers, prior to the carraige of passengers.
Due 20 May 2005
Resolved 20 April 2005
Communications › Radio Communications
Issued 5 May 2004
Resolved
Repair and prove operation of single side band. Vessel is restricted to operation within 20 miles of shore until this item is completed. LEGACY COMPONENT DESC: Radiotelephone Transceiver (2-27.5 MHz)
Due 5 June 2004
Resolved 15 June 2004
Navigation › Piloting/Steering
Issued 5 May 2004
Resolved
Provide light for magnetic compass. LEGACY COMPONENT DESC: Magnetic Compass
Due 5 June 2004
Resolved 15 June 2004
Fire Fighting › Fixed Fire Detection System
Issued 5 May 2004
Resolved
Demonstrate operation of fire alarm system in the engine room. LEGACY COMPONENT DESC: Heat Detectors
Due 5 June 2004
Resolved 15 June 2004
Electrical › Electric Supply System (service) › Cable
Issued 1 July 2003
Resolved
Provide electrical one line drawing.
Due 16 July 2003
Resolved 9 July 2003
Navigation › Piloting/Steering › Deviation Table/Graph
Issued 5 May 2003
Resolved
Provide compass deviation table.
Due 31 July 2003
Resolved 9 July 2003
Lifesaving › Inflatable Liferafts › Capacity
Issued 5 May 2003
Resolved
Install six man inflatable liferaft. Total persons allowed on any route extending beyond 20 miles is reduced to 20 until this item is completed.
Due 30 June 2004
Resolved 9 July 2003
Resolution: Owner elects to permanently reduce total capacity on oceans routes to 20, and used 6-man liferaft only for commercial fishing.
Engineering › Bilge Water Management System › Piping
Issued 5 May 2003
Resolved
Repair piping and demonstrate operation of bilge pumping system prior to carriage of passengers.
Due 8 July 2003
Resolved 4 July 2003
Documentation › Safety/Response Plans/Programs
Issued 5 May 2003
Resolved
Provide and post Emergency Instructions prior to carriage of passengers. LEGACY COMPONENT DESC: emergency instructions
Due 8 July 2003
Resolved 4 July 2003