Records from 2016 to 2023. Most recent: inspection, 4 May 2023.
Inspection history · 11
4 May 2023
COE-Administrative · Administrative Inspection · COC-TVE Annual · PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7680937
28 March 2023
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7658317
23 March 2023
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7655509
15 October 2022
COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7577831
14 September 2022
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7553842
5 May 2022
Administrative Inspection · COC-TVE Renew
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7444541
24 April 2022
COE-Administrative
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7436960
23 April 2022
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7436474
27 October 2019
ISPS II Exam · COC-TVE Annual · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6843183
21 November 2018
Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6581220
20 December 2016
ISPS II Exam · COC-TVE Annual · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6047553
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 May 2023
Resolved
In tankers, electrical equipment shall not be installed in hazardous locations, unless it conforms with the standards not inferior to those acceptable to the organization. 7 explosion proof lamps in the port and starboard deck storage were found with cracked lenses, the cracked pump room lights were on the bottom platform near the #1 ballast pump, platform 5 over the ballast piping, platform 4 near the staircase adn emergency stretcher lift, platform 2 same as platform 4, platform 1 over the staircase. All 4 lamps in the deck stores were cracked. vessel authorized to shift to berths and transit to anchorage.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 May 2023
Resolved 13 May 2023
Resolution: Received LR Class Report indicating all explosion proof lights were installed and fully operational.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 May 2023
Resolved
Except as permitted by the administration... all metal sheaths and armour of cables shall be electrically continuous and shall be earthed. Bonding strap on the electrical wire run was wasted and disconnected.
74SOLAS 20 II/1/45.5.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 11 May 2023
Resolved 11 May 2023
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 May 2023
Resolved
vapor collection piping must be electrically bonded to the hull and continuous bonding straps on the vapor line was wasted and disconnected. deficiency cleared on the spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 11 May 2023
Resolved 11 May 2023
Resolution: RESOLVED ON THE SPOT
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 May 2023
Resolved
ALL CARGO TANKS, PIPING, VALVES,ETC. SHALL BE SUFFICENTLY GROUNDED TO THE VESSELS HULL. BANDING STRAPS ON THE CARGO STRIPPING LINE, AND M.A.O. BUNKER LINE WERE WASTED AND DISCONNECTED, DEFICIENCY CLEARED ON THE SPOT.
46CFR 38.15-15(C)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 11 May 2023
Resolved 11 May 2023
Resolution: RESOLVED ON THE SPOT
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 4 May 2023
Resolved
SOPEP EQUIPMENT: THE EQUIPMENT AND SUPPLIES MUST INCLUDE NON-SPARKINGHAND SCOOP, SHOVELS, AND BUCKETS.
VESSEL HAD TWO METALLIC SPARKING SHOVELS STORED ON-DECK IN THE SPILL RESPONSE KIT. DEFICENCY CLEARED ON THE SPOT.
33CFR 155.205(B)(2)
Action required: 10 - Deficiency Rectified
Due 11 May 2023
Resolved 11 May 2023
Resolution: RESOLVED ON THE SPOT