Records from 2016 to 2021. Most recent: inspection, 14 May 2021.
Inspection history · 4
14 May 2021
Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7197107
13 October 2020
PSC B · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7076011
8 November 2016
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6037337
22 August 2016
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5979517
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 13 October 2020
Resolved
Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. PSCO observed broken bilge pump connection to bilge, unapproved bilge cover, and an unapproved tiller on the rescue boat. PSCO is requesting update on steering alarm issue prior to departure. 74SOLAS(14)III/20.2 17AC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 October 2020
Resolution: New tiller ordered, existing tiller replaced with straight type repair. Conditional SOLAS Safety Equip. cert issued by Class. Authorization letter received from Flag.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 October 2020
Resolved
Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards will be ensured. PSCO observed unapproved electrical installations and splicing in the officer and crew laundry. 74SOLAS(09)II-1/40.1.3 40AC
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 May 2021
Resolution: Received, reviewed, and accepted class NKK report. Crew rewired the laundry machine connections properly.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 13 October 2020
Resolved
Fire protection systems including structural fre protection, fire-resisting divisions, and protection of openings and penetrations shall be maintained. PSCO noted grease seeping through vent ducting connections in galley. 74SOLAS(14)II-2/14.2.1 40AC
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 May 2021
Resolution: Received, reviewed, and accepted class NKK Class report. Crew cleaned vent duct and vent damper.
Operations/Management › Ballast Water Managment › Mandatory Practices
Issued 22 August 2016
Resolved
33CFR151.2050(f)- Remove fouling organisms from the vessel's hull, piping, and tanks on a regular basis and dispose of any removed substances in accordance with local, state, and federal regulations.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 8 November 2016
Resolution: NKK confirmed hull cleaning at Veracruz, Mexico at 05-12 SEP 2016
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 22 August 2016
Resolved
74 SOLAS (2014 Cons Ed)II-I/3-9.3- For all ships, the means of embarkation and disembarkation shall be inspected and maintained in suitable condition for their intended purpose taking into account any restrictions related to safe loading. Accommodation ladder net improperly secured.
Action required: 15 - Rectify deficiencies by next port
Resolved 8 November 2016
Resolution: NKK confirmed replacement of net for accomodation ladder and properly secured at Veracruz, Mexico 05-12 SEP 2016.