MAURY USCG vessel records
← All vessels

BW CLEAR SKY

BW CLEAR SKY is a 2011 tank ship. The Coast Guard has recorded 20 inspections since 2016, most recently in October 2025, along with 5 deficiencies and 1 operational control.

Records from 2016 to 2025. Most recent: inspection, 20 October 2025.

Built
2011
Last inspected
20 October 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 20 October 2025
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9413327
9V9665
1146601
Flag
SINGAPORE
Maury page id
psix-1146601

Documentation record

Tonnage as PSIX records it36217 - Convention (Subpart B), Net Ton
100395 - Dead Weight, Metric Ton
131668 - Displacement, Metric Ton
109949 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 20

20 October 2025 Administrative Inspection · PSC B · COC-GAS Renew
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8251485
10 October 2025 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8250590
3 September 2024 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7995507
30 March 2024 COC-GAS Renew · PSC B
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7882399
29 March 2024 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7882483
4 December 2023 Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7833407
19 August 2023 COC-GAS Annual · PSC B
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7765650
1 February 2022 PSC B · COC-GAS Renew
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7386497
1 July 2021 Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7241235
11 December 2020 COC-GAS Annual · PSC B
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7105653
10 December 2020 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7109842
11 September 2020 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7054432
31 August 2020 COE-Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7046942
8 November 2019 ISPS II Exam · Ballast Water Examination · COC-GAS Renew
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6845262
8 November 2019 Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 7089580
29 January 2019 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6616820
1 November 2018 COC-GAS Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6570714
29 October 2017 Ballast Water Examination · COC-GAS Renew · ISPS II Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6295042
6 April 2016 ISPS II Exam · Ballast Water Examination · Deficiency Check · COC-GAS Renew
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5852023
5 April 2016 Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 6093245

Deficiency record · 5

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 20 October 2025 Resolved
ELECTRICAL EQUIPMENT SHOULD BE SUCH AS TO MINIMIZE THE RISK OF FIRE & EXPLOSION FROM FLAMMABLE PRODUCTS. PSCO OBSERVED 02 EXPLOSION PROOF ENCLOSURES IN CARGO SUBCOOLER ROOM THAT WERE NOT PROPERLY SEALED. {93 IGC 10.1.2}
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 15 March 2026
Resolved 20 October 2025
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 6 April 2016 Resolved
Pressure relief valve should be set and sealed by a competent authority acceptable to the administration and a record of this action, including the valves of set pressure should be retained aboard the ship. The #2 cargo safety relief valve (#22619) is not sealed. Vessel could not provide port state control officers with a record of relief valve settings.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 8 April 2016
Resolution: Vessel provided necessary documentation. Master issued a written statement that the valve setting has not been tampered with. Classification Society Surveyor (Bureau Veritas) ensured new tag and seal were placed on #2 cargo tank relief valve.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 6 April 2016 Resolved
Emergency shutdown valves in liquid lines should fully close under all service conditions within 30 seconds of actuation. Port state control officers observed all 8 (4 port and 4 starboard) manifold liquid lines took 32 to 35 seconds to close after activating the emergency shutdown.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2016
Resolved 6 April 2016
Resolution: Vessel crew was able to adjust timing of emergency shutdown valves before end of the port state control examination. Port state control officers observed all 8 manifold liquid lines closing under 30 seconds after activating emergency shutdown.
Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 6 April 2016 Resolved
The gas detection equipment should be capable of sampling and analysing for each sample head location sequentially at intervals not exceeding 30 minutes. Port state control officers obeserved an open valve in the cabinet of gas sample system which was diluting the samples. This prevented the system from showing an accurate reading from any of the sample points.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2016
Resolved 6 April 2016
Resolution: Vessel crew closed valve and let gas detection system properly sample each head location within 30 minutes. Vessel crew properly calibrated system and no alarms sounded while system took samples.
Deck/Cargo › Vapor Control Systems › Vapor Destruction Unit
Issued 6 April 2016 Resolved
Unless a cargo tank carrying LNG can withstand the pressure build up due to boil-off for 21 days, the pressure in the cargo tank must be maintained below the set pressure of the safety relief valve for at least 21 days by a waste heat or catalytic furnace. Following a test of the master gas valve for the gas combustion unit, the crew could not restart the gas combustion unit.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 6 April 2016
Resolved 6 April 2016
Resolution: Vessel crew was able to bring gas combustion unit back online prior to conclusion of port state control examination.

Ownership record