MAURY USCG vessel records
← All vessels

WEB 329

WEB 329 is a 2013 tank barge. The Coast Guard has recorded 13 inspections since 2012, most recently in June 2023, along with 3 deficiencies.

Records from 2012 to 2023. Most recent: inspection, 28 June 2023.

Built
2013
Last inspected
28 June 2023
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 28 June 2023
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2012–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

1146816
Flag
UNITED STATES
Maury page id
psix-1146816

Documentation record

Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 13.0 ft
Registered tonnagegross 1,754 / net 1,754
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSOUTHWEST SHIPYARDS LP · HOUSTON, TX, UNITED STATES · built 2013
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 14 January 2026 · expires 28 February 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1754 - Simplified, Gross Ton
1754 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 13

28 June 2023 Damage Survey · Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7725753
26 February 2023 Internal Structural Exam · Cargo Tank Internal · Administrative Inspection · Drydock Exam · COI Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7642092
16 April 2020 MTSA Verification · Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6939988
18 April 2019 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6666342
23 January 2019 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6613996
22 May 2018 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6420489
12 March 2018 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6370387
14 February 2018 Administrative Inspection · Internal Structural Exam · Examination of Repairs · MTSA Verification · COI Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6355128
8 February 2017 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6083542
12 November 2015 Periodic Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5768995
14 January 2015 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5052168
20 March 2014 Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4819643
11 October 2012 Initial Certification · Drydock Exam · Cargo Tank Internal · Administrative Inspection · MTSA Verification · COI Inspection · Construction Oversight
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4509709

Deficiency record · 3

02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 28 June 2023 Resolved
Scantlings, material, and workmanship, subdivision of cargo spaces, fitting of cofferdams, and testing of tanks shall be at least equivalent to the requirements of the American Bureau of Shipping or other recognized classification society. Marine Inspector observed 24" x 20" approx. 3" inset on the STBD #1 raised cargo trunk. Vessel is authorized a one time transit to offload current cargo within OCMI zone then immediately transit to repair facility within OCMI zone to enact permanent repairs to the satisfaction of a CG Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 August 2023
Resolved 13 July 2023
Resolution: Cropped and renewed one (1) portion of shaped cargo tank coaming 3/8" x 42" x 3'6" and one (1) portion of tank top plate 3/8" x 24" x 2'0". Conducted a visual exam of all repairs and witnessed air test at 1.0 PSI. Test satisfactory.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 18 April 2019 Resolved
(d)Navigation lights. Each navigation light must meet the following: (1) Meet the technical details of the applicable navigation rules. (2) Be certified by an independent laboratory to the requirements of UL 1104 (incorporated by reference; see 46 CFR 110.10-1) or an equivalent standard under 46 CFR 110.20-1. Portable battery powered lights need meet only the requirements of the standard applicable to those lights. (3) Be labeled with a label stating the following: (i) “MEETS _____.” (Insert the identification name or number of the standard under paragraph (d)(2) of this section to which the light was type-tested.) (ii) “TESTED BY _____.” (Insert the name or registered certification mark of the independent laboratory that tested the fixture to the standard under paragraph (d)(2) of this section). (iii) Manufacturer's name. (iv) Model number. (v) Visibility of the light in nautical miles. (vi) Date on which the fixture was type-tested. (vii) Identification of bulb used in the compliance test.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2019
Resolved 1 May 2019
Resolution: Company replaced Nav Lights with approved UL 1104 type. All Sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 April 2019 Resolved
c) Every portable fire extinguisher must be supplied with a suitable bracket which will hold the extinguisher securely in its stowage location on vessels or boats, and which is arranged to provide quick and positive release of the extinguisher for immediate use. During vibration testing, the extinguisher must be tested in the marine bracket.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2019
Resolved 1 May 2019
Resolution: Vessel rep stated it is their company policy to only have their required fire fighting equipment on board the vessel during a transfer. 02 40B have been removed from the vessel.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.