MAURY USCG vessel records
← All vessels

PAN SPIRIT

PAN SPIRIT is a 2009 tank ship. The Coast Guard has recorded 3 inspections since 2017, most recently in January 2018, along with 3 deficiencies.

Records from 2017 to 2018. Most recent: inspection, 24 January 2018.

Built
2009
Last inspected
24 January 2018
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 24 January 2018
Operational controls None recorded without a removal date
Years with a record 2 calendar years (2017–2018)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9378266
1147622
Flag
SINGAPORE
Maury page id
psix-1147622

Documentation record

Tonnage as PSIX records it10200 - Dead Weight, Ton
14800 - Displacement, Ton
8199 - Convention (Subpart B), Net Ton
8331 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 3

24 January 2018 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6342673
15 December 2017 Administrative Inspection · ISPS II Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6324182
28 July 2017 COC-CHEM Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6222308

Deficiency record · 3

Engineering › Generator (propulsion/auxiliary-electric) › Battery
Issued 28 July 2017 Resolved
Solas (2004 Cons.) II-1/44.2 Each emergency generating set arranged to be automatically started devices approved by the administration with a stored energy capability of at least three consecutive starts. A second source of energy shall be provided. Secondary means of starting emergency generator, which was batteries, did not work.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 August 2017
Resolved 30 July 2017
Resolution: Provided class report with deficiency rectified.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 28 July 2017 Resolved
Solas 74 (2014 Cons.) III/13.4 LSA Code 4.4.8.12 Each survival craft shall be stowed fully equipped as required by this chapter and the code. The normal equipment of every lifeboat shall consist of a food ration totalling not less than 10,000 KJ for each person the lifeboat is permitted to accomodate. The lifeboat is rated for 25 persons. Only 18 out of 25 food rations were satisfactory.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 August 2017
Resolved 30 July 2017
Resolution: Provided class report with deficiency rectified.
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 28 July 2017 Resolved
IGC (93) 8.2.5 MARV pilot pressure relief valves seals missing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 August 2017
Resolved 30 July 2017
Resolution: Provided class report with deficiency rectified.

Ownership record