Records from 2016 to 2025. Most recent: inspection, 11 April 2025.
Documentation record
Registered dimensions (L × B × D)35.0 ft × 11.0 ft × 4.0 ft
Registered tonnagegross 10 / net 8
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBENTZ BOATS LLC · LEWISTON, ID, UNITED STATES · built 2011
Hull materialAluminum
PropulsionJet Drive
Hull shapeShip
Hull configurationMonohull
Hailing portJUNEAU, AK
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 29 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it10 - Simplified, Gross Ton
8 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 19
11 April 2025
COI Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8101567
24 March 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8099005
30 April 2024
Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7896587
6 April 2023
Internal Structural Exam · COI Inspection · Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7651065
15 November 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7587769
29 March 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7420996
7 October 2021
Internal Structural Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7328874
7 May 2021
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7214705
14 April 2021
Internal Structural Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7175122
28 October 2020
Hull Examination
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7099434
8 October 2020
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7074046
31 October 2019
Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6847304
23 October 2019
Administrative Inspection · Internal Structural Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6842216
22 April 2019
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6668109
28 March 2019
Hull Examination · Administrative Inspection · Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6651654
10 April 2018
Internal Structural Exam · DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6373199
3 May 2017
Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6138453
2 March 2017
Internal Structural Exam · Hull Examination
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6097751
28 April 2016
Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5864292
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 11 April 2025
Resolved
Each door, hatch, or scuttle, used as a means of escape, must be capable of being opened by one person, from either side, in both light and dark conditions. The method of opening a means of escape must be obvious, rapid, and of adequate strength. Handles and securing devices must be permanently installed and not capable of being easily removed. A door, hatch or scuttle must open towards the expected direction of escape from the space served. The aft sliding door internal door handle is missing rendering door unable to be properly operated from inside cabin space. Replace/repair aft sliding door and ensure proper operation of door to the satisfaction of attending marine inspector.
46 CFR 177.500 (h)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 April 2025
Resolution: Rectified
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 11 April 2025
Resolved
Each item of lifesaving equipment with an expiration date must be replaced during the annual inspection and repair if the expiration date has passed. EPIRB Hydrostatic release unit (HRU) expired. Replace HRU with new or serviced unit to the satisfaction of the attending marine inspector.
46 CFR 185.126 (c)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 April 2025
Resolution: Rectified
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 April 2024
Resolved
(b)(4) Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. If the handle to the shutoff valve at the tank is located inside the machinery space, it must be located so that the operator does not have to reach more than 300 millimeters (12 inches) into the machinery space and the valve handle must be shielded from flames by the same material the hull is constructed of, or some noncombustible material. Electric solenoid valves must not be used, unless used in addition to the manual valve.
Shutoff valve did not fully rotate to the closed position. Vessel rep repaired prior to MI departure.
Action required: 10 - Deficiency Rectified
Resolved 30 April 2024
Resolution: Valve fully closes.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 April 2024
Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (2 1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket.
Vessel only had two 2.5 gallon fire buckets. Vessel rep placed third fire bucket on vessel prior to MI departure.
Action required: 10 - Deficiency Rectified
Resolved 30 April 2024
Resolution: New 2.5 gallon bucket placed into service on vessel.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 30 April 2024
Resolved
(d) A power-driven vessel of less than 12 meters in length may, in lieu of the lights prescribed in paragraph (a) of this Rule, exhibit an all-round white light and sidelights
All around masthead light was found extinguished. Vessel rep replaced in kind prior to MI departure.
Action required: 10 - Deficiency Rectified
Resolved 30 April 2024
Resolution: New masthead light installed
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 April 2024
Resolved
(d)(3) Each floating waterlight installed after March 11, 1997, on a vessel carrying only one ring buoy, must be attached to the lanyard with a corrosion-resistant clip. The clip must have a strength of at least 22.7 kilograms (50 pounds), and allow the waterlight to be quickly disconnected from the ring life buoy.
Float missing corrosion resistant clip. Vessel rep installed new corrosion resistant clip prior to MI departure.
Action required: 10 - Deficiency Rectified
Resolved 30 April 2024
Resolution: Corrosion resistant clip installed on float light
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 30 April 2024
Resolved
(b)(1)(ii) Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew.
Educated vessel rep on importance of proper inspections and documentation of portable fire extinguishers.
Action required: 10 - Deficiency Rectified
Resolved 30 April 2024
Resolution: Educated vessel rep on procedures.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 15 November 2022
Resolved
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may conduct an internal structural examination in any affected space including fuel tanks, and may require the vessel to be drydocked or taken out of service to assess the extent of the damage, and to effect permanent repairs. Discovered three cracked longitudinal stitch welds along the keel starting approximately 2' aft of the main cabin fwd door. Complete repairs to satisfaction of the attending CG Marine Inspector. 46 CFR 176.600
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2023
Resolution: Cracked welds repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 November 2022
Resolved
The construction, installation, and operation of propulsion and auxiliary machinery, piping and pressure systems, steering apparatus, and associated safety systems. Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. The starboard jet bucket control cable boot seal has deteriorated away and is partially missing. Properly repair/replace starboard bucket control damaged boot seal. 46 CFR 182.100
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2023
Resolution: Boot seal replaced.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 29 March 2022
Resolved
Vessel did not have crew available to conduct crew drills. Conduct crew drills with marine inspector prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 April 2022
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 29 March 2022
Resolved
Vessel did not have crew available. Provide proof of drug consortium enrollment for all crew members.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 April 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 May 2021
Resolved
Life jackets were stowed in the overhead storage and the location was not labeled. Mark location with number and size of life jackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2021
Resolved 4 June 2021
Resolution: Storage location is now marked.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 May 2021
Resolved
A life jacket donning placard was not provided for both types of life jackets carried on board vessel. Provide life jacket donning placard for all types of life jackets onboard vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2021
Resolved 4 June 2021
Resolution: New donning placard was provided for both types of life jackets.
Construction/Loadline › Hull › Stringer
Issued 10 April 2018
Resolved
During annual ISE found 25 plus cracked welds in the area from anchor locker bulkhead under fwd steps to just behide the first cross frame aft, along with one broken/missing long. Frame and 2 cracked frames in need of repair
Action required: 705 - Other - as specified
Due 24 April 2018
Resolved 17 April 2018
Resolution: Vessel has repaired all crakced welds, frames and reistalled missinf framing, all sat.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 28 April 2016
Resolved
Provide updated coast pilot, light list, and paper chart.
Action required: 705 - Other - as specified
Due 12 May 2016
Resolved 3 May 2016