Records from 2001 to 2002. Most recent: inspection, 6 December 2002.
A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 4
6 December 2002
Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1714147
4 April 2002
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1602083
1 February 2002
Re-Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1483388
14 September 2001
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 293759
Personnel › Certificates/Documents/Licenses
Issued 6 December 2002
No resolution recorded
Provide Flag acceptance for Officer licenses
Action required: 705 - Other - as specified
Due 15 January 2003 — due date passed with no resolution recorded
Personnel › Certificates/Documents/Licenses
Issued 6 December 2002
No resolution recorded
Provide medical exam cetificate for crew members
Action required: 705 - Other - as specified
Due 6 January 2003 — due date passed with no resolution recorded
Navigation
Issued 6 December 2002
No resolution recorded
Update charts
Action required: 15 - Rectify deficiencies by next port
Due 6 December 2002 — due date passed with no resolution recorded
Navigation
Issued 6 December 2002
Resolved
Provide day shapes
Action required: 17 - Rectify deficiencies prior to departure
Due 6 December 2002
Resolved 6 December 2002
Resolution: corrected
Fire Fighting
Issued 6 December 2002
No resolution recorded
Provide proper vari nozzle for fire hose iaw CCSSC 3.5.10 and 3.5.11
Action required: 15 - Rectify deficiencies by next port
Due 6 December 2002 — due date passed with no resolution recorded
Construction/Loadline
Issued 6 December 2002
No resolution recorded
Make permanent structural repairs to the aft lazarette bulkhead
BULKHEAD HAD IN EXCESS OF 50 PITTED WEEPING HOLES, HOLES HAD BEEN SPACKLED TO STOP THE MIGRATION OF WATER FROM THE BALLAST TANK INTO LAZARETTE
Action required: 705 - Other - as specified
Due 6 December 2002 — due date passed with no resolution recorded
Construction/Loadline
Issued 6 December 2002
No resolution recorded
Provide belt UT report from last dry dock, if not complete, complete and submit results to RIO St. Croix
Action required: 15 - Rectify deficiencies by next port
Due 6 December 2002 — due date passed with no resolution recorded
Accommodation/Occupational Safety › Cooking Systems › Cooking Fuel
Issued 1 February 2002
Resolved
Renew cooking stove fuel hose.
Condition: Improper Installation
Due 1 February 2002
Resolved 1 February 2002
Accommodation/Occupational Safety › Cooking Systems
Issued 1 February 2002
Resolved
Provide evidence of flag/class approval of galley cooking stove installation LEGACY COMPONENT DESC: Cooking Fuel
Condition: Placed in Improper Service
Due 1 March 2002
Resolved 4 April 2002
Resolution: corrected
Accommodation/Occupational Safety › Cooking Systems
Issued 1 February 2002
Resolved
Renew galley hood vent screen. LEGACY COMPONENT DESC: vent
Due 1 February 2002
Resolved 1 February 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 1 February 2002
Resolved
Remove obstructions from engine room emergency escapes. LEGACY COMPONENT DESC: obstruction
Due 1 February 2002
Resolved 1 February 2002