ESL MUNDRA

ESL MUNDRA is a 2000 freight ship. The Coast Guard has recorded 24 inspections since 2000, most recently in September 2026, along with 11 deficiencies and 4 operational controls.

Records from 2000 to 2026. Most recent: inspection, 8 September 2026.

Built
2000
Last inspected
8 September 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9200706 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
LIBERIA
—
Maury page id
psix-11489

Inspections, by type

…with no type recorded9
Years with a record 12 calendar years (2000–2026)
The 24 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it36993 - Convention (Subpart B), Net Ton
68819 - Dead Weight, Metric Ton
93049 - Displacement, Metric Ton
66278 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ENDEAVOR Towing Vessel · MISLE 11288 · 17 March 2023 · activity 7654544

Inspection history · 24

8 September 2026 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8484324
10 November 2023 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7821991
6 November 2023 PSC B · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7820724
1 November 2023 Deficiency Check · PSC B · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7818278
17 March 2023 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7654544
13 March 2023 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7648281
10 March 2023 Ballast Water Examination · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7650083
9 March 2023 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7648501
12 December 2022 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7608135
21 September 2022 Deficiency Check · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7563576
10 September 2022 PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7549452
19 July 2015 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5185416
4 September 2011 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4134178
12 February 2010 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3676069
26 September 2008 PII Safety Exam · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3332679
3 July 2008 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3256315
26 November 2007 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3104898
17 March 2007 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2890142
23 October 2006 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2806809
31 July 2006 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2731374
24 November 2002 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1710462
28 September 2001 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 294214
27 October 2000 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 283552
5 August 2000 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 280826

Deficiency record · 11

07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 6 November 2023 Resolved
Oil fuel lines shall be suitably protected to avoid as far as practical oil leakage onto hot surfaces. PSCO observed excessive pooling of fuel oil on top of the #3 Generator. 74 SOLAS (01) II-2/15.11
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 November 2023
Resolved 9 November 2023
Resolution: DNV: No:3 A/E, leaking lub oil pipe connections at No:5 & No:6 units were found replaced with new o-rings accordingly.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 6 November 2023 Resolved
Fire-Extinguishing appliances shall be in good working order and be available for immediate use. PSCO observed two CO2 bottles had pins installed which would have prevented a minimum of 37 Co2 bottles of the 403 required bottles from discharging in the case of a fire. 74 SOLAS (01) II-2/21
Action required: 10 - Deficiency Rectified
Due 6 November 2023
Resolved 6 November 2023
Resolution: Pins were removed.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 6 November 2023 Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. In meeting these requirements, the company should ensure that: inspections are held at appropriate intervals; appropriate corrective action is taken. The shipboard procedures require monthly checks of the CO2 system by the vessel’s crew and all items were marked as being compliant but as evident in deficiency #2 the system was found not compliant during this exam. The vessel’s chief engineer standing orders require daily rounds and cleaning of engine room. However based on deficiency #1 it was observed excessive oil leaks on the #3 generator. Additionally, it was observed that the vessel’s flag state conducted an audit of the vessel SMS three days prior to this exam and did not have any observations related to these deficiencies. Due to the objective evidence in the above deficiencies, the vessel is not in substantial compliance with relevant conventions. The Captain of the Port questions the adequacy and overall implementation of the vessel's SMS under the ISM Code. An EXTERNAL audit is required within 30 days to determine whether the ship is operating in accordance with the ISM Code. Provide a copy of the audit report to USCG when completed. 74 SOLAS (20) IX/13.1. ISM CODE Part A 10.1 and 10.2
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 December 2023
Resolved 6 December 2023
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 1 November 2023 Resolved
The company and the ship shall comply with the requirements of the International Safety Management Code. For the purpose of this regulation, the requirements of the Code shall be treated as mandatory. The Company should identify equipment and technical systems the sudden operational of failure which may result in hazardous situations. The safety management system should provide for specific measures aimed at promoting the reliability of such equipment or systems. PSCOs observed severe degradation of the main engine high-pressure fuel delivery jacketing lines and the associated fuel oil piping. The failure of the jacketed piping allowed oil to leak onto the heated surfaces of the main engine casing. After reviewing the ship’s maintenance procedures, routine maintenance was being conducted with the last servicing of the cylinders being March 2023. However, the SMS did not specifically address the fuel delivery system piping, therefore routine maintenance was not conducted on this critical system. Based on the overall material condition of the fuel delivery system as sustained by the objective evidence cited above, an external audit is required. 74 SOLAS (20) IX/3.1 ISM CODE PART A.10.3
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 November 2023
Resolved 2 November 2023
Resolution: Received and reviewed Class report attesting to the completeness of an ISM Audit.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 1 November 2023 Resolved
All external high-pressure fuel delivery lines between the high-pressure fuel pumps and fuel injectors shall be protected with a jacketed piping system capable of containing fuel from a high-pressure line failure. 7 out of the 10 high-pressure fuel delivery jacketing lines for main engine cylinders were found leaking, repaired with patches, missing bolts, and wasted to the extent that the fuel lines were exposed. One area of main engine fuel injector supply piping was missing all required bolts for installation and was being secured to the main engine by a natural rope. The condition of the jacket piping exposed the fuel lines which caused chaffing and allowed fuel oil to leak onto main engine casing and containment. 74 SOLAS (01) II-2/15.9
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 November 2023
Resolved 2 November 2023
Resolution: Received and reviewed Class report attesting to the proper repair and rectification of the 07 high pressure fuel lines that were identified as wasted.
07 - Fire Safety › N/A - No Subsystem › Jacketed high pressure lines and oil leakage alarm
Issued 1 November 2023 Resolved
Oil fuel lines shall be suitably protected to avoid, as far as practicable, oil spray or oil leakages onto hot surfaces. Damaged high pressure fuel delivery lines are causing fuel oil to leak onto heated main engine components. 74 SOLAS (04) II-2/15.11
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 November 2023
Resolved 2 November 2023
Resolution: Received and reviewed Class report attesting to the clean up and removal of the oil leaks on the main engine in vicinity of the M/E cylinders.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 1 November 2023 Resolved
Every steam pipe and every fitting connected thereto through which steam may pass shall be so designed, constructed and installed as to withstand the maximum working stresses to which it may be subjected. L.O purifier heater, HFO purifier heater No 2, M/E fuel oil heater 2 valves, auxiliary boiler freshwater pump, and main valves for auxiliary boiler were observed actively leaking water and steam, causing pools of water underneath equipment and poses safety hazard to the crew. 74 SOLAS (04) II-1/33.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 November 2023
Resolved 2 November 2023
Resolution: Received and reviewed Class report attesting to the proper repair and rectification of the various steam leaks throughout the engine room.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 10 September 2022 Resolved
In a ship in which oil fuel is used, the arrangements for the storage, distribution, and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons on board. PSCO observe oil accumulation in the vicinity of the main engines.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2022
Resolved 21 September 2022
Resolution: Received Class documentation to the proper repairs and clean up of the accumulated oil that was observed. Refer to DEF Document for further information.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 10 September 2022 Resolved
A food ration totaling not less than 10,000 kj for each person shall be kept in an airtight packaging. PSCO observer 03 food rations in the port and 01 food rations in the starboard lifeboats damaged and not in an airtight packaging.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2022
Resolved 21 September 2022
Resolution: Received Class documentation on the delivery of required food rations. Refer to DEF Document for further information.
Navigation › Piloting/Steering › Gyro Compass
Issued 3 July 2008 Resolved
Received LOD for an inoperable gyro compass.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 July 2008
Resolution: Received tech report stating that the gyro compass is now operating normally.
Lifesaving
Issued 5 August 2000 Resolved
PROVIDE MUSTER LIST AND EMERGENCY INSTRUCTION IN PASSENGER BERTHING PRIOR TO CARRYING PASSENGER OR NEXT US PORT._x001C_ (VESSEL REQUESTED A PASSENGER FREGHT VESSEL EXAM)
Condition: Unknown
Due 27 October 2000
Resolved 27 October 2000

Ownership record