Records from 2016 to 2025. Most recent: inspection, 27 October 2025.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 27 October 2025
Resolved
A vessel must carry a first-aid kit under approval series 160.041 with equivalent contents. Eye wash and aspirin expired. Replenish expired items.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2025
Resolved 30 October 2025
Resolution: Expired items replinsished.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 27 October 2025
Resolved
A vessel on a lakes, bays, and sounds, or river route must carry 3 hand red flares and 3 orange smoke signals for a total of 06. A hand red flare may be substituted for a hand orange smoke distress signal.
01 hand orange smoke distress signal showed signs on damage. Replace with either hand red flare OR hand orange smoke distress signal.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2025
Resolved 30 October 2025
Resolution: New flares on board.
12 - Dangerous Goods › N/A - No Subsystem › Fire protection cargo deck area
Issued 29 October 2024
Resolved
The design, construction, and stowage of portable tanks and related fuel lines and accessories must meet the requirements of ABYC H-25 (incorporated by reference; see 46 CFR 175.600) or other standard specified by the Commandant.
Both vessels portable gasoline tanks are delaminated and cracking. Install new in kind tanks.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 November 2024
Resolved 1 November 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 October 2024
Resolved
A suitable metal marine type strainer, meeting the requirements of the engine manufacturer, must be fitted in the fuel supply line in the engine compartment. Fuel filter needs to be replaced along with hardware. Replace with in-kind material.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 November 2024
Resolved 1 November 2024
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 29 October 2024
Resolved
Except as otherwise allowed by this subpart, a vessel must comply with the structural design requirements of one of the standards listed below for the hull material of the vessel. Both PORT and STBD side of the vessel has cracked hull/deck material. Make in-kind repairs and make available to attending MI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 November 2024
Resolved 1 November 2024
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 29 October 2024
Resolved
Crew training shall be logged or otherwise documented for review by the Coast Guard upon request. Vessel was missing log book. Provide log book for the attending MI.
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 November 2024
Resolved 1 November 2024
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 29 October 2024
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets and immersion suits. Life jacket compartments were missing quantity, size, and markings. Properly label life jacket compartments on board.
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 November 2024
Resolved 1 November 2024
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage
Issued 29 October 2024
Resolved
A ship, except a ship of less than 26 feet in length, must have a placard of at least 5 by 8 inches, made of durable material fixed in a conspicuous place in each machinery space, or at the bilge. Stating: Discharge of Oil Prohibited. Vessel was missing oil placard. Install correct oil placard.
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 November 2024
Resolved 1 November 2024
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 October 2023
Resolved
Portable and semi-portable fire extinguishers are to be maintained iaw NFPA-10. The owner or managing operator must provide the USCG with satisfactory evidence that appropriate monthly maintenance is being conducted. Vessel had no evidence that monthly portable fire extinguisher maintenance was being performed. Vsl must provide adequate log entries or a maintenance record for all portable fire extinguishers. 46 CFR 176.810
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 November 2023
Resolved 25 October 2023
Resolution: Operator provided log entries showing monthly fire extinguisher maint.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 October 2023
Resolved
Child life jackets must be appropriately segregated from other sized life jackets onboard. Vessel had all life jackets stowed under the bow with no segregation for child sized life jackets. Vessel must provide a suitable location and identification for all child sized life jackets.46 CFR 180.78
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2023
Resolved 25 October 2023
Resolution: Segregation for lifejackets provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 October 2023
Resolved
Lifejackets are required to meet the requirements oulined in 46 CFR 160.002 which include providing adequate dawning instructions. Vessel had instructions posted but for the wrong type of lifejacket. Vessel must provide adequate lifejacket dawning instructions for the make and model lifejackets carried.46 CFR 180.72
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 November 2023
Resolved 25 October 2023
Resolution: Correct dawning instructions provided
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 24 October 2023
Resolved
Sufficient navigational reference material must be provided onboard for the intended route and service. Vessel navigational charts and publications were all expired. Vessel must provide adequate navigational publications, references and charts for the intended route and operation.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 November 2023
Resolved 25 October 2023
Resolution: Correct and current nav publication excerpts provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 October 2023
Resolved
Lifering waterlights must have a lanyard at least three feet long but not more than six. Vessel's waterlight lanyard was longer than six feet. Vessel must provide a waterlight lanyard in compliance with this part.46 CFR 180.70
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 November 2023
Resolved 25 October 2023
Resolution: Lifering lanyard shortened to six feet.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 January 2023
Resolved
The regulations in this part provide a means to minimize the use of intoxicants by merchant marine personnel and to promote a drug free and safe work environment. Owner could not provide valid drug and alcohol program during inspection. Provide proof of enrollment in consortium, current employee list, and Employment Assistance Program (EAP) to include 800 hot-line posted. 46 CFR 16.500
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 January 2023
Resolution: A valid Consortium letter with crew list was onboard the vessel.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 January 2023
Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. Owner could not provide satisfactory evidence for conducting monthly inspections on port side fire extinguisher. Service extinguisher using qualified facility. 46 CFR 176.810
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 January 2023
Resolution: Fire extinguisher was renewed.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 24 January 2023
Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must have the vessel ready for inspection of its fire protection equipment, including the following: (1) Inspection of each portable fire extinguisher, check for excessive corrosion and general condition; Starboard side extinguisher found un-serviceable due to gauge sightglass full of water. Renew in kind. 46 CFR 176.810
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 January 2023
Resolution: Fire extinguisher was renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 January 2023
Resolved
The design, construction, and stowage of portable tanks and related fuel lines and accessories must meet the requirements of ABYC H-25 (incorporated by reference; see 46 CFR 175.600) or other standard specified by the Commandant. Portside fuel tank was found with a crack and possible leaking. Remove portable fuel tank or renew. 46 CFR 182.458
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 January 2023
Resolution: Fuel tank renewed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 January 2023
Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (2 1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. Vessel only had two fire buckets onboard during inspection. 46 CFR 181.610
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 January 2023
Resolution: Additional fire bucket added to vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 January 2023
Resolved
Each floating water light must be approved in accordance with § 161.010 in subchapter Q of this chapter, or other standard specified by the Commandant. Life Ring Buoy water light was found non operable. Vessel restricted to daytime operations. 46 CFR 180.70
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2023
Resolved 30 January 2023
Resolution: Waterlight renewed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 January 2023
Resolved
A vessel of less than five net tons is excluded from documentation. Provide the original State issued registration on board. 46 CFR 67.9
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 January 2023
Resolved 30 January 2023
Resolution: The original State issued registration is now on board.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 January 2023
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Provide donning placards for both type of life jackets. 46 CFR 185.516
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 February 2023
Resolved 30 January 2023
Resolution: Donning placards for both type of life jackets are properly posted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 January 2023
Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a) only on a vessel of not more than 19.8 meters (65 feet) in length carrying not more than 49 passengers, other than a ferry, provided that: The pump is permanently mounted. Properly secure submersible pump in the bilge. 46 CFR 182.520
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 February 2023
Resolved 30 January 2023
Resolution: Bilge pump properly secured.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 January 2023
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Several items in the kit were found un-serviceable.
A vessel must comply with the applicable requirements for any radio installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Provide a VHF radio onboard the vessel with integrated GPS and DSC capabilities to conduct test call. 46 CFR 184.710 46 CFR 184.502
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 February 2023
Resolved 30 January 2023
Resolution: New first aid kit with watertight container is placed on board.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 24 January 2023
Resolved
Abandon ship and man overboard drills are to be conducted at least once within a 3 month period. Vsl has not recorded drills or training in more than one year. Vsl must provide evidence that Abandon ship and man overboard drills are being conducted iaw this part. 46 CFR 185.520
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 February 2023
Resolved 30 January 2023
Resolution: Logged quarterly emergency drills.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 24 January 2023
Resolved
The owner/master is responsible to ensure proper crew training is taking place. Attending marine inspectors witnessed an MOB and Fire Drill. Both drills were UNSAT. Master must perform MOB and Fire Drill to the satisfaction of the attending USCG marine inspector. 46 CFR 185.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 February 2023
Resolved 30 January 2023
Resolution: Witnessed satisfactory drill.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 24 January 2023
Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radio beacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Provide a VHF radio onboard the vessel with integrated GPS and DSC capabilities to conduct test call.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 February 2023
Resolved 30 January 2023
Resolution: VHS radio integrated with GPS with DSC capabilities installed on the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 June 2022
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. While underway, capt noticed outboard was starving for fuel. After further investigating, a fuel leak was discovered coming from the outboard rigging loom. Vessel was towed to Radio Island Marina where they found the OEM fuel adapter in the loom had failed causing the leak. The marina replaced the hose with in-kind material and MI performed a satisfactorily operation test. All SAT. Vessel is operational.
Action required: 10 - Deficiency Rectified
Resolved 27 June 2022
Resolution: M/I conducted a satisfactorily def check. New fuel hose is USCG approved. OP test SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 October 2021
Resolved
Materials and workmanship. The materials and construction of fuel lines, including pipe, tube, and hose, must comply with the requirements of this paragraph. Gasoline fuel line was deteriorated beyond repairs.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 October 2021
Resolution: Fuel hose was replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 October 2021
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Aspirin was expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 November 2021
Resolved 3 November 2021
Resolution: Vessel operator bought new aspirin for kit
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 October 2021
Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. Vessel was missing both lights. Only one is required at the operating station due to the vicinity of the outboard.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 November 2021
Resolved 3 November 2021
Resolution: Vessel operator bought two new working flashlights.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 October 2021
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Adult and child life jackets were stored together and the child life jacket quantity was not labeled properly.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 November 2021
Resolved 3 November 2021
Resolution: Life jackets are properly stowed with the correct quanity amount.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 October 2021
Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a). Provide hand pump.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 November 2021
Resolved 3 November 2021
Resolution: Vessel operator bought new hand pump IAW the regulation.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 28 October 2021
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (1) Charts of large enough scale to make safe navigation possible; (2) U.S. Coast Pilot or similar publication; (3) Coast Guard Light List; (4) Tide tables; and (5) Current tables, or a river current publication issued by the U.S. Army Corps of Engineers or a river authority. (b) Extracts from the publications listed above for the areas to be transited may be provided instead of the complete publication. Vessel was missing multiple publications.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 November 2021
Resolved 3 November 2021
Resolution: Vessel operator was able to provide all missing pubs and charts IAW the regualtion.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 28 October 2021
Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation, in which case no floating waterlight is required. Light was not attached to life ring.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 November 2021
Resolved 3 November 2021
Resolution: Vessel operator moved light and attached it to a life ring.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 28 October 2021
Resolved
Each battery used in an item of lifesaving equipment, must be replaced during the annual inspection if the expiration date of the battery has passed. Battery expired 2019.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 November 2021
Resolved 3 November 2021
Resolution: Vessel operator replaced light battery with valid date.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 October 2021
Resolved
Small batteries. Each small battery installation must be located in a well ventilated space and protected from falling objects. Battery box was missing cover.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 November 2021
Resolved 3 November 2021
Resolution: Vessel operator installed cover properly over battery box.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 28 October 2021
Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (21/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. Buckets were not labeled.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 November 2021
Resolved 3 November 2021
Resolution: Vessel operator labeled all buckets IAW regulation.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 October 2021
Resolved
Connections must be made to battery terminals with permanent type connectors. Battery connector had wing nut installed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 November 2021
Resolved 3 November 2021
Resolution: Vessel operator installed proper hardware. All SAT
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 October 2021
Resolved
Electrical equipment on a vessel must be installed and maintained to: (b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Remove dead-end wire under console.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 November 2021
Resolved 3 November 2021
Resolution: Vessel operator reconnected loose wire to navigation equipment. All SAT
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 21 October 2020
Resolved
First Aid Kit are expired; Provide aspirin and Ammonia.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2020
Resolved 12 November 2020
Resolution: Asprin and ammonia provided in kit. Photos provided by onwner.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 October 2020
Resolved
Renew Anchor.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2020
Resolved 22 October 2020
Resolution: Anchor was replaced
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 October 2020
Resolved
04 adult life jackets are unservicable, vessel restricted to 17 persons onboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 November 2020
Resolved 22 October 2020
Resolution: 04 Life jackets were renewed and properly labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 October 2020
Resolved
01 child size life jacket is unservicable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 November 2020
Resolved 22 October 2020
Resolution: 01 child sized lifejacket was renewed
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 October 2020
Resolved
Provide 2A size fire extinguisher onboard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2020
Resolved 5 November 2020
Resolution: New fire ext. provided. Cleared using objective evidence photos.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 October 2020
Resolved
Provide proper bracket for port side fire extinguisher.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2020
Resolved 5 November 2020
Resolution: New bracket provided, cleared using objective evidence.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 21 October 2020
Resolved
Install new connector on negative wire on battery. Prove proper operation of bilge, radio, navigation lights, and horn.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 October 2020
Resolved 22 October 2020
Resolution: New connection was installed and proved operation
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 October 2020
Resolved
Replace or renew life ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2020
Resolved 12 November 2020
Resolution: New life ring provided objective evidence via photos.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 October 2020
Resolved
Provide boot cover on negative side of battery.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2020
Resolved 22 October 2020
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 21 October 2020
Resolved
Crack on bimini frame.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2020
Resolved 12 November 2020
Resolution: Cleared using photos of weld repair
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 October 2020
Resolved
Install additional life ring buoy iaw COI.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2020
Resolved 22 October 2020
Resolution: Installed additional life ring buoy
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 October 2020
Resolved
Alcohol test strips are expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2020
Resolved 12 November 2020
Resolution: Alcohol test trips provided, photos provided.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 21 October 2020
Resolved
Provide coast pilot, light list, tide tables, and marine charts.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2020
Resolved 5 November 2020
Resolution: Provided photo objective evidence.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 October 2019
Resolved
5 adult and 4 child lifejackets found faded and torn. Limited to requirements of COI.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 November 2019
Resolution: New lifejackets purchased and properly labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 29 October 2019
Resolved
Found expired MEDs asprin
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 November 2019
Resolution: New meds onboard
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 October 2019
Resolved
torn life line for ring buoy.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 November 2019
Resolution: new line installed
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 29 October 2019
Resolved
Gel coat has chips on the stbd side midship. Grind and reglass
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 November 2019
Resolution: Repaired with Gel coat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 October 2019
Resolved
bilge discharge hose held together with electrical tape, wiring not prioperly spliced, and bilge pump not properly mounted.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 November 2019
Resolution: Bilge system inspected and tested SAT. new through hull installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 October 2019
Resolved
Fuel bowl is plastic
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 November 2019
Resolution: new metal fuel bowl installed
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 29 October 2019
Resolved
Provide radio station license.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 November 2019
Resolution: New radio station license provided.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 29 October 2019
Resolved
Console has several holes throughout, seal all holes on console.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 November 2019
Resolution: All holes sealed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 29 October 2019
Resolved
Owner removed stern pad eye. Reinstall.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 November 2019
Resolution: New pad eye installed
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 29 October 2019
Resolved
Conduct MOB drill and Fire drill.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 November 2019
Resolution: MOB Drill and Fire drill conducted SAT.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 October 2019
Resolved
MISSING 2 buckets and one is a 5 gallon bucket
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 November 2019
Resolution: new buckets on vessel.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 13 November 2018
Resolved
CAPT missing FFC radio operators permit. Limited to 1000ft from shore.
Action required: 705 - Other - as specified
Resolved 16 November 2018
Resolution: Op. Permit provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 November 2018
Resolved
Hand rails and hardware port and STBD side loose
Action required: 705 - Other - as specified
Due 28 November 2018
Resolved 13 November 2018
Resolution: Rails tightened and verified by OWNER/OPERATOR
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 November 2018
Resolved
Loose fire ext. bracket
Action required: 705 - Other - as specified
Due 28 November 2018
Resolved 16 November 2018
Resolution: Fire ext bracket tight.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 November 2018
Resolved
One life jacket ripped due to deterioration.Limited to 20 Passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 November 2018
Resolved 13 November 2018
Resolution: Installed properly marked life jacket
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 November 2018
Resolved
Remove small plastic step stool from vsl.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 November 2018
Resolution: Removed steps
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 November 2018
Resolved
Install missing safety chain on forward handrail leading to the bow.
Action required: 705 - Other - as specified
Due 28 November 2018
Resolved 15 November 2018
Resolution: Installed safety chain
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 13 November 2018
Resolved
Cracked hand rails on console stbd side and forward handrail at bow.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 December 2018
Resolved 15 January 2019
Resolution: Handrails welded and inspected SAT.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 13 November 2018
Resolved
Missing stability letter at time of inspection
Action required: 705 - Other - as specified
Due 13 December 2018
Resolved 15 November 2018
Resolution: E-mailed picture of stability letter SAT.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 November 2018
Resolved
Missing distress signals
Action required: 705 - Other - as specified
Due 13 November 2018
Resolved 13 November 2018
Resolution: Purchased new
Construction/Loadline › Hull › Keel
Issued 25 October 2017
Resolved
Inner skeg fwd port and stbd sand and repair.
Action required: 705 - Other - as specified
Due 24 November 2017
Resolved 27 October 2017
Resolution: repaired both skeg section with FRP
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 25 October 2017
Resolved
Conduct MOB and Fire drill once vessel is underway
Action required: 705 - Other - as specified
Due 24 November 2017
Resolved 6 November 2017
Resolution: Conducted underway trails and drills all SAT
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 25 October 2017
Resolved
Repaint vsl name on port and stbd side
Action required: 705 - Other - as specified
Due 24 November 2017
Resolved 27 October 2017
Resolution: Name repainted on side of vessel
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 25 October 2017
Resolved
Replace lifeline on ring buoy and retro tape
Action required: 705 - Other - as specified
Due 24 November 2017
Resolved 27 October 2017
Resolution: Installed new life line on ring buoy
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 25 October 2017
Resolved
Provide approved first aid kit 46CFR160.014
Action required: 705 - Other - as specified
Due 24 November 2017
Resolved 6 November 2017
Resolution: Replaced with new approved first aid kit
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 25 October 2017
Resolved
Embarcation port top chain spring clip needs to be replaced.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 November 2017
Resolved 27 October 2017
Resolution: Installed new spring clip for safety chain
Electrical › Electric Supply System (service) › Battery Installation
Issued 25 October 2017
Resolved
Secure battery
Action required: 705 - Other - as specified
Due 24 November 2017
Resolved 6 November 2017
Resolution: Secured battery with strap
Lifesaving › Hand Flares › Expired
Issued 1 November 2016
Resolved
Need to replace one Red hand flare
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 December 2016
Resolved 1 December 2016
Resolution: Verified proper number of flares.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 1 November 2016
Resolved
First Aid kit has expired meds.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2016
Resolved 1 December 2016
Resolution: Verified proper medications.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 1 November 2016
Resolved
FWD Nav light burnt out. Port and STBD
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2016
Resolved 1 December 2016
Resolution: Tested Navigation Lights.
Lifesaving › Lifefloat › Markings
Issued 1 November 2016
Resolved
Remark all life jacket stowage areas.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2016
Resolved 1 December 2016
Resolution: Life Jacket storage was re-marked.
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 1 November 2016
Resolved
Remove current line safety lines and reinstall with approved safety lines or safety chains,
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 December 2016
Resolved 1 December 2016
Resolution: Safety lines have been reinstalled.
Navigation › Piloting/Steering › US Coast Pilot
Issued 1 November 2016
Resolved
Provide updated NAV Pub, Coast Pilot, Tide & Current table, and charts for area of operations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2016
Resolved 1 December 2016
Resolution: Verified updated and proper publications.