Records from 2021 to 2025. Most recent: inspection, 21 July 2025.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 21 July 2025
Resolved
Fire Doors in the main vertical zone bulkheads...shall be self closing. PSCO observed 01 A-60 self-closing door on upper engine room escape hatch not closing.
74SOLAS(04)II-2/9.4.1.1.4
10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 21 July 2025
Resolved 21 July 2025
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 21 July 2025
Resolved
Fixed fire detection and fire alarm system installations shall be suitable for the nature of the space. PSCO observed 01 smoke detector above hot water tank covered with plastic.
74SOLAS(04)II-2/7.1.1
10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 21 July 2025
Resolved 21 July 2025
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 16 August 2021
Resolved
Before ship leaves port and at all times during the voyage, all life-saving appliances shall be ready for immediate use. Liferafts were all found to be fixed improperly. All need to be fixed, so hydrostatic release will properly inflate raft and appliance is ready for immediate use.
Cite: 74SOLAS(20) III/20.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 August 2021
Resolution: Ship crew corrected attached line to weak link on all four liferafts.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 16 August 2021
Resolved
Means of control for flammable liquids in the space shall be provided to limit the fire growth potential. Dozens of 5 gallon buckets were found in the E/R containing varying levels of flammable liquids. Specifically behind the ECR in the passageway, and on the 2nd deck of the E/R underneath a STBD side fuel tank. All containers and barrels containing flammable liquids and oily waste need to be removed, stored, and disposed of as per the vessel's waste management plan.
Cite: 74SOLAS(20) II-2/5.1.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 August 2021
Resolution: Ship crew removed all unsused buckets that housed flammable, corrosive, and othe material. All inspected areas have been thoroughly cleaned.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 16 August 2021
Resolved
Fixed fire detection and fire alarm system installation shall be suitable for the nature of the space. Fire growth potential, and potential generation of smoke and gases. PSCO observed 01 smoke detectors covered with plastic. All smoke detectors in E/R need to be checked and free of any obstructions.
Cite: 74SOLAS(20) II-2/7.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 August 2021
Resolution: Ship crew uncovered smoke detector and inspector conducted satisfactory test. Crew verified all fire detection detectors in E/R were cleared of any obstructions.
10 - Safety of Navigation › N/A - No Subsystem › Pilot ladders and hoist/pilot transfer arrangements
Issued 16 August 2021
Resolved
Arrangements shall be provided to enable pilot to embark and disembark safely on either side of the ship. Embarkation ladder was found to be severely wasted at its connection point to deck and needs replacement.
Cite: 74SOLAS(20) V/23.3.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 August 2021
Resolution: Ship crew completely replaced worn ladder with a spare embarkation ladder that was onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 August 2021
Resolved
The machinery, boilers, and other pressure vessels, associated piping systems and fittings...shall be so installed and protected as to reduce to a minimum any damage to persons onboard due regard being paid to...hot surfaces and other hazards. 01 machinery pipe were found with oil soaked lagging around it.
Cite: 74SOLAS(20)II-1/26.1
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 16 August 2021
Resolution: Ship crew replaced lagging on the spot during initial inspection.