← All vessels
WL ATLANTIC
WL ATLANTIC is a 2010 freight ship. The Coast Guard has recorded 10 inspections since 2016, most recently in May 2024, along with 4 deficiencies and 2 operational controls.
Records from 2016 to 2024. Most recent: inspection, 30 May 2024.
- Built
- 2010
- Last inspected
- 30 May 2024
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 4 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9489417 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
VRVA3
1152802
Flag
HONG KONG
—
Maury page id
psix-1152802
Inspections, by type
…with no type recorded2
Years with a record
3 calendar years (2016–2024)
The 10 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it33465 - Dead Weight, Metric Ton
43721 - Displacement, Metric Ton
24079 - Convention (Subpart B), Gross Ton
10640 - Convention (Subpart B), Net Ton
43721 - Displacement, Metric Ton
24079 - Convention (Subpart B), Gross Ton
10640 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 10
30 May 2024
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7922955
20 May 2024
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7915578
20 May 2024
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7915761
11 February 2017
Bulk Liquid Transfer Monitor
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6086536
10 February 2017
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6086090
18 January 2017
In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6073473
17 January 2017
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6071575
9 January 2017
NPV Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6064430
3 January 2017
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6065322
2 February 2016
Deficiency Check · Administrative Inspection · Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5794545
Deficiency record · 4
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 30 May 2024
Resolved
The purpose of this regulation is to prevent the ignition of combustable materials or flammable liquids. For this purpose, the following functional requirements shall be met: means shall be provided to control leaks of flammable liquids. PSCO observed multiple HFO Leaks in purifier romm coming from HFO Separator Pump, HFO Fuel Line from the mix tank, and bypass regulator valve, as well as oil soaked lagging on the bypass regulator valve and HFO line from the mix tank.
17 a.c. - 74SOLAS(20)II-2/4.1.1
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 30 May 2024
Resolved
The purpose of this regulation is to prevent the ignition of combustable materials or flammable liquids. For this purpose, the following functional requirements shall be met: means shall be provided to control leaks of flammable liquids. PSCO observed oil accumilation on No.1 & No.2 Generator.
16 a.c. - 74SOLAS(20)II-2/4.1.1
Electrical › Electric Generation Source (service) › Generator
Issued 18 January 2017
Resolved
0950 - Electric Equipment in General - A main source of electrical power of sufficient capacity to supply all those services mentioned in regulation 40.1.1 shall be provided. This main source of electrical power shall consist of at least two generating sets. PSCO observed that 2 o 3 generating sets were inoperable. 74 SOLAS (14) II-1/41.1.1 60a
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 2 February 2016
Resolved
EQUIPMENT WHICH MAY CONSTITUTE A SOURCE OF IGNITION OF FLAMMABLE VAPOUR SHALL NOT BE PERMITTED WITHIN CARGO SPACES ONBOARD SHIPS CERTIFIED T CARRY DANGEROUS CARGO. PSCO IDENTIFIED TWO LIFE BUOY LIGHTS NOT MARKED AS INTRINSICALLY SAFE IN CARGO DECK AREA.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.