ULUSOY-12 is a 2011 freight ship. The Coast Guard has recorded 9 inspections since 2016, most recently in August 2019, along with 11 deficiencies and 4 operational controls.
Records from 2016 to 2019. Most recent: inspection, 20 August 2019.
- Built
- 2011
- Last inspected
- 20 August 2019
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 11 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9586423 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
TCZU5
1153317
Flag
TURKEY
—
Maury page id
psix-1153317
Inspections, by type
The 9 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it26510 - Convention (Subpart B), Net Ton
79421 - Dead Weight, Metric Ton
93287 - Displacement, Metric Ton
43717 - Convention (Subpart B), Gross Ton
79421 - Dead Weight, Metric Ton
93287 - Displacement, Metric Ton
43717 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 9
20 August 2019
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6784620
18 August 2019
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6787106
3 January 2018
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6332163
3 January 2018
Ballast Water Examination · Administrative Inspection · PII Safety Exam · ISPS II Exam · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6332177
2 January 2018
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6338703
9 February 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5812224
4 February 2016
PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5809460
24 January 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5802485
23 January 2016
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5802245
Deficiency record · 11
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Valves
Issued 31 January 2016
Resolved
0725 Fixed Fire Extinguishing Installations- PSCO noted that the primary supply valve for the water mist system protecting the engine room equipment was in the closed positon rendering the system inoperable. SOLAS II-2/14.1
Fire Fighting › Remote Fuel Shutoff › General
Issued 31 January 2016
Resolved
0799 Other (Fire Fighting Equipment) PSCO observed that the primary air supply valve that controls the operation of all quick close fuel valves in the engine room was in the closed position. This configuration rendered the system inoperable and is not in align with posted operational procedures. SOLAS II-2/14.1
Engineering › Fuel Oil Service System › Pump
Issued 31 January 2016
Resolved
9800-Other (Clearly Hazardous) PSCO observed an active fuel leak in the aft port corner of the low pressure fuel supply for the main porpulsion engine estimaged at an approximate lieter of fuel per minute allow flammable liquied to be discharged into the engine room bilge. SOLAS I/11 a
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 31 January 2016
Resolved
0740-(Oil Discharge Mon/contr system) PSCO noted that the oil content meter tamper seal that reads "Calibration Seal Void if Broken" was cut and entry into the OCM has occured since the last Calibration dated 06/03/2013. MARPOL Annex I Regulation 14.7, MEPC 107(49)
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder
Issued 31 January 2016
Resolved
1410(Propulsion Main Engine) Internal comustion engines of 2250 Kw or having cylinders of 300mm shall be equipt with Oil Mist detection systems. Veseels Oil Mist Detection is showing an active alarm on the No.7 Cylinder. SOLAS II-1/47.2
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 31 January 2016
Resolved
0999-(Other Not Clearly Hazardous) PSCO observed three independent oil storage tanks located within the engineroom with sight glasses locked in the open position with custom fabricated metal clips. SOLAS XI-1/4.1
Fire Fighting › Combustible Materials › Insulation
Issued 31 January 2016
Resolved
1470 (Insulation Wetted Through Oil) PSCO observed numerous sections of fuel/oil saturated lagging on components integral to the main proplusion engine. SOLAS II-2/4.1
Pollution Prevention/Response › Prevention Equipment › Portable Containment
Issued 31 January 2016
Resolved
2120 (Garbage) Ships on board garbage management plan states that the vessel is allowed to store two drums of oily rags in the engine room. Currently vesse is storing five completely full 55 gallon drums of oily soaked rages in the engine room. MARPOL V Reg. 10.2
Electrical › Lighting (service) › Lighting Fixture
Issued 31 January 2016
Resolved
1499 (Other Prop. & Aux Machinery) Lighting fixutre in teh Emergency Generator Space located behind the switch board is dismantled and inoperable. SOLAS I-11 a.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 31 January 2016
Resolved
1745 (15ppm alarm arrangeemnts) PSCO witnessed high pressure water spraying from the fresh water flushing line on the oily water seperator due to a cracked nipple. SOLAS I-11 a.
Fire Fighting › Fixed Fire Detection System › Flame Detectors
Issued 31 January 2016
Resolved
2515 (Company Responsibility and Authority) PSCO's observed crew testing flame detectors with open flame. Crew was unable to produce on board SMS procedures for testing of installed somke/heat/flame detection systems therefore the PSCO's could not attest to this being an approved testing method. SOLAS IX/3 ISM REG 7.