ATHANASIA is a 2010 freight ship. The Coast Guard has recorded 9 inspections since 2019, most recently in August 2025, along with 8 deficiencies and 2 operational controls.
Records from 2019 to 2025. Most recent: inspection, 8 August 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it41748 - Displacement, Metric Ton 32701 - Dead Weight, Metric Ton 20809 - Convention (Subpart B), Gross Ton 11786 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 9
8 August 2025COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8205478
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 11 July 2025Resolved
The condition of the ship and its equipment shall be maintained to confrom with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board.
PSCO observed fire, general service, and bilge pumps inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 July 2025
Resolution: Fire pump and general service pumps were overhauled, and then tested satisfactorily.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 11 July 2025Resolved
Muster and embarkation stations shall be adequately illuminated by lighting supplied from the emergency source of power.
PSCO observed embarkation light for forward liferaft unable to be installed due to corrosion both port and starboard mounting points. Additionally observed missing hardware on frame of light and exposed wiring at junction box on light housing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 July 2025
Resolution: Both port and starboard mounting points were reconditioned and then lights were successfully remounted. Additionally, missing hardware on light frame was replaced with new bolts and exposed wires were properly addressed.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 11 July 2025Resolved
Doors required to be self closing shall ot be fitted with hold back devices.
PSCO observed hold backs on self closing class A fire doors from crew and officers mess into pantries and from pantries into galley as well as from the galley to provisions. Additionally observed closure device removed from port side a/c room door.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 July 2025
Resolution: Surveyor tested self-closing mechanisms and found in good order. Also removed hold back devices.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 11 July 2025Resolved
Before the ship leaves port and at all times during the voyage, all life saving appliances shall be in owkring order and ready for immediate use.
PSCO observed resuce boat missing painter line and fire extinguisher gauge in the red.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 July 2025
Resolved 11 July 2025
Resolution: Deficiency cleared prior to completing PSC B exam.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 14 October 2022Resolved
Electrical installations shall be such that: all electrical auxiliary services necessary for maintaining the ship in normal operational and habitable conditions will be ensured without recourse to the emergency source of electrical power. PSCO was informed that the vessel lost power due to a faulty circuit breaker. Satisfactory technician report required prior to movement. SOLAS(20)II-1/40.1
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 22 October 2022
Resolution: Received tech report and class survey attesting to proper repairs being made to vessel's circuit board.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 August 2019Resolved
13199-OTHER-THE MACHINERY, BOILERS, AND OTHER PRESSURE VESSELS, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE SO INSTALLED AND PROTECTED AS TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS ON BOARD. PSCOs WITNESSED MULTIPLY OIL LEAKS IN THE ENGINE ROOM. OIL LEAKS WERE OBSERVED ON THE BUNKER LINES, FUEL LINES FOR THE MAIN ENGINE, AND ALL THREE GENERATORS.
SOLAS 74 (2014) II-1/26.1 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 August 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 August 2019Resolved
13199-OTHER-THE MACHINERY, BOILERS, AND OTHER PRESSURE VESSELS, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE SO INSTALLED AND PROTECTED AS TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS ON BOARD. PSCOs WITNESSED JACKET COOLING WATER LEAKS ON MULTIPLY MAIN ENGINE CYLINDERS.
SOLAS 74 (2014) II-1/26.1 17ac
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 August 2019
04 - Emergency Systems › N/A - No Subsystem › Emergency steering position com./ compass reading
Issued 9 August 2019Resolved
04106-A GYRO-COMPASS HEADING REPEATER, OR OTHER MEANS, TO SUPPLY HEADING INFORMATION VISUALLY AT THE EMERGENCY STEERING POSITION IF PROVIDED. THE GYRO REPEATER AT THE EMERGENCY STEERING POSITION HAD A DEVIATION OF APROXIMATELY 43 DEGREES FROM THE MASTER GYRO.
SOLAS 74 (2014) V/19.2.5.2 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure