SMYRNI is a tank ship. The Coast Guard has recorded 6 inspections since 2018, most recently in April 2023, along with 1 deficiency and 1 operational control.
Records from 2018 to 2023. Most recent: inspection, 12 April 2023.
This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
The counts in the strip above are the same counts; this table splits the inspections by
the kind of activity recorded. A blank resolution means none was recorded in this data; it
does not establish that a deficiency is outstanding. Years with a record are calendar
years in which a record exists, not years in service.
What Maury does not do.
Documentation record
Tonnage as PSIX records it83562 - Convention (Subpart B), Gross Ton 83562 - Regulatory (Subpart C or D), Gross Ton 149998 - Dead Weight, Ton 49022 - Convention (Subpart B), Net Ton 49022 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
What it gives that this page does not: the whole record in one
dated, citable document — every line with its Coast Guard activity id, the retrieval
date on the cover, built to print to PDF with its page breaks — that a surveyor can
attach and a lender can file. The same facts as this page, complete and in one file.
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
A request, not a checkout: leave an email and Maury replies once, with
the dated document for this hull and a Stripe invoice for $299. Nothing is charged before
the document is in your hands.
Used only to answer this request.
Not shared, not sold, and not added to a mailing list.
Inspection history · 6
12 April 2023Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7667137
25 March 2023Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7656786
22 March 2023COC-TVE Renew · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7644991
22 May 2018Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6414740
22 May 2018Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6420377
18 May 2018Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6417806
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 22 March 2023Resolved
An approved fixed gas warning system capable of monitoring flammable vapours shall be provided in cargo pump rooms, pipe ducts and cofferdams.
Vessels fixed gas system could not continuously monitor for flammable vapours, and continuously gave a "fault" alarm. Vessels screen for fixed gas monitoring in the pump room was completely malfunctioning, showing inaccurate numbers and symbols spontaneously.
74SOLAS CONS. (2004) II-2/4.5.4.2
34ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 11 April 2023
Resolution: The vessel 1. replaced the Fixed Gas System Display Unit with a new like original display unit.
2. The display system and alarms were tested to the satisfaction of the attending Surveyor, and found to be working normally.
3. All is considered satisfacto
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.