MAURY USCG vessel records Sign in
← All vessels

STINNES ZEPHIR

STINNES ZEPHIR is a 2011 public freight. The Coast Guard has recorded 31 inspections since 2011, most recently in March 2025, along with 5 deficiencies and 9 operational controls.

Records from 2011 to 2025. Most recent: inspection, 28 March 2025.

Built
2011
Last inspected
28 March 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9473236 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1154416
Flag
ANTIGUA AND BARBUDA
—
Maury page id
psix-1154416

Inspections, by type

…with no type recorded7
Years with a record 12 calendar years (2011–2025)
The 31 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it17211 - Dead Weight, Metric Ton
23711 - Displacement, Metric Ton
12795 - Convention (Subpart B), Gross Ton
5486 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 31

28 March 2025 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8101158
12 November 2024 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8033438
11 November 2023 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7823224
3 May 2023 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7675870
15 August 2022 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7530080
15 October 2021 PSC B
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 7331681
23 July 2021 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7263037
12 July 2021 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7254136
8 April 2021 Ballast Water Examination · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7170941
8 July 2020 PSC A
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6998220
7 July 2020 Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6999220
25 April 2020 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6943883
25 January 2019 Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 6612717
20 January 2019 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6610856
13 September 2018 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6539632
7 July 2018 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6470310
2 July 2018 Ballast Water Examination · ISPS II Exam · NPV Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6453256
3 March 2018 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6364168
18 February 2018 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6357194
13 February 2018 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6354186
5 February 2018 ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6349509
12 January 2018 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6337101
17 June 2017 PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6178665
9 February 2017 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6082204
24 May 2016 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5879835
18 May 2016 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5880284
13 October 2015 Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5741379
13 October 2015 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5776936
24 December 2011 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4213481
23 December 2011 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4215298
18 December 2011 ISPS II Exam · COE-Dockside · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4207132

Deficiency record · 5

14 - Pollution Prevention › 141 - MARPOL Annex I › 15 PPM Alarm arrangements
Issued 15 August 2022 Resolved
In considering design of the oil filtering equipment and oil content meter, the administration shall have regard to the specification recommended by the organization. The 15 PPM bilge alarm should record date, time and alarm status, and operating status of the 15 PPM bilge separator. The oil content meter does not record the operating status of the system. Data missing from 15JUN22 when system was last operated. MARPOL ANNEX I/14
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 September 2022
Resolution: Compnay Replaced oil content monitoring unit. Provided class report.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 8 April 2021 Resolved
EACH EMERGENCY GENERATING SET ARRANGED TO BE AUTOMATICALLY STARTED SHALL BE EQUIPPED WITH STARTING DEVICES APPROVED BY THE ADMINISTRATION WITH A STORED ENERGY CAPABILITY OF AT LEAST THREE CONSECUTIVE STARTS. SHIP'S CREW ATTEMPTED TO START THE EMERGENCY GENERATOR THREE TIMES WITHIN 30 MINUTES AND COULD NOT START THE SYSTEM. WITH THE PART STATE CONTROL TEAM STILL ON-BOARD, THE CREW INSTALLED A NEW BATTERY AND SUCCESSFULLY STARTED THE EMERGENCY GENERATOR.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 April 2021
Resolved 8 April 2021
Resolution: RESOLVED WITH PORT STATE CONTROL TEAM STILL ON-BOARD.
Electrical › Electrical Distribution System (emergency) › Panelboard
Issued 24 May 2016 Resolved
Electrical installations shall be such that the safety of the passengers, crew, and ship from electrical hazards will be ensured. Emergency switchboard found with opening exposing internal components.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 24 May 2016
Resolution: Ship's crew rivoted a steel plate over the opening.
Electrical › Electric Generation Source (service) › Generator
Issued 13 October 2015 Resolved
1410 - Propulsion Main Engine - the condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel experienced a loss of propulsion on its inbound trip to Tampa. SOLAS 74(2015 CONS) 1/11. 17ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 October 2015
Resolved 27 October 2015
Resolution: Received, reviewed and accepted class report from LR stating that the power loss was caused by a loss of cooling water supplies. The affected cooler was repaired.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 23 December 2011 Resolved
The vessel experienced a power loss while in the Mississippi River.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 December 2011
Resolved 28 December 2011
Resolution: Received, reviewed and accepted class report from GL stating the generators were repaired, tested and found satisfactory.

Ownership record