← All vessels
ALIKI FORCE
ALIKI FORCE is a 2011 freight ship. The Coast Guard has recorded 12 inspections since 2011, most recently in January 2026, along with 13 deficiencies and 1 operational control.
Records from 2011 to 2026. Most recent: inspection, 31 January 2026.
- Built
- 2011
- Last inspected
- 31 January 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 13 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9498559 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7AL7
1155500
Flag
MARSHALL ISLANDS
—
Maury page id
psix-1155500
Inspections, by type
…with no type recorded1
Years with a record
7 calendar years (2011–2026)
The 12 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it58419 - Dead Weight, Metric Ton
89919 - Displacement, Metric Ton
34402 - Convention (Subpart B), Gross Ton
19580 - Convention (Subpart B), Net Ton
89919 - Displacement, Metric Ton
34402 - Convention (Subpart B), Gross Ton
19580 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 12
31 January 2026
PSC B · Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8304366
8 December 2020
PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7101932
25 November 2020
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7101928
8 June 2017
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6170389
5 June 2017
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6159358
29 May 2017
COE-Administrative · Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6159354
20 May 2016
Ballast Water Examination · Random ISPS/MTSA/PSC · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5881791
12 May 2016
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5875677
20 April 2016
Administrative Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5858373
18 September 2015
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5717932
11 May 2012
Administrative Inspection
Administrative · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 4308271
28 September 2011
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4149278
Deficiency record · 13
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 31 January 2026
Resolved
BEFORE THE SHIP LEAVES PORT AND AT ALL TIMES DURING THE VOYAGE, ALL LIFE SAVING APPLIANCES SHALL BE IN WORKING ORDER AND READY FOR IMMEDIATE USE.
PSCOOBSERVED RESCUE BOAT FAIL TO START WHEN ATTEMPTING OPERATIONAL TEST.
Electrical › Electric Generation Source (emergency) › Conductor
Issued 5 June 2017
Resolved
74 SOLAS(14)I/11(a): The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea with danger to the ship or persons on board. PSCO found approximately 4 liters of fuel oil under electrical non-conductive matting in emergency generator room.
Lifesaving › Rescue Boat › Markings
Issued 5 June 2017
Resolved
74 SOLAS (09) III/20.2: BEFORE THE SHIP LEAVES PORT AND AT ALL TIMES DURING THE VOYAGE, ALL LIFE-SAVING APPLIANCES SHALL BE IN WORKING ORDER AND READY FOR IMMEDIATE USE. THE RESCUE BOAT SPONSONS ADHESIVE TABS TO TRANSOM ARE/HAVE BECOME UNATTACHED COMPROMISING INTEGRITY ON FLOTATION TO HULL REQUIRING REPAIRS TO MANUFACTURERS RECOMMENDATIONS.
Lifesaving › Rescue Boat › Propulsion Engine
Issued 20 May 2016
Resolved
0615; Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. The crew has been testing the rescue boat engine without using cooling water. No cooling water was observed exiting the water pump indicating hole, which is indicative of a damaged impeller. Continued in general information.
Engineering › Sea-water System (primary cooling) › Piping
Issued 20 May 2016
Resolved
1499: The machinery and associated piping systems and fittings shall be of a design adequate for the service for which they are intended. Four welded patches were found on the S/W cooling lines both on the inlet and outlet pipe to the plate for ships service generators. Exhaust insulation for generator is worn/missing or wasted, 74SOLAS(14)II-1/26, 17ac.
Operations/Management › Log/Records › Ballast Water Logs/Records
Issued 20 May 2016
Resolved
2510; Vessel must maintain a ballast water plan that has been developed specifically for the vessel that will allow those responsible for the plan to understand and follow it. However, the ballast management plan and the bio-fouling plan has not been fully implemented. Not all items have been addressed and the crew is unfamiliar with the plan. Continued on general information.
Fire Fighting › Fixed Fire Detection System › Flame Detectors
Issued 20 May 2016
Resolved
0120; The function of fixed fire fighting detection and alarm system shall be periodically tested. The vessel does not have appropriate means of testing the flame detectors. Crew is currently using an open flame. Appropriate equipment must be onboard prior to departure, 74SOLAS(14)II-1/14, 17ac.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 20 May 2016
Resolved
2035; Fire control plan shall be kept up to date. Currently fire control plan in passage ways does not reflect the current condition. Ship's bonded store locker has been changed to a locker for the steward. The cleaning gear locker on the B deck has been changed to the bonded stores. Both have not been changed on the Fire Control Plan, 74 SOLAS(09)II-2/15, 17ac.
Documentation › Logs/Records › Oil Record Book
Issued 20 May 2016
Resolved
1710; The oil record book part 1 shall be completed on each occasion, whenever any of the machinery is operations takes place on the ship. From 23 May 2015 until 20 May 2016 the crew has been incorrectly recording operation under the code C and item number 12.2 MARPOL 73/78 Annex I/17, 10c.
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 20 May 2016
Resolved
1705; Every ship 400 GT and above shall carry a Shipboard Oil Pollution Emergency Plan. The plan onboard does not have port authority listed appendix 3 as per section 2.2.3.2 and forms being used has not been approved, MARPOL I/37.2.4, 10c.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 20 May 2016
Resolved
2120; Every ship shall carry a Garbage Management Plan which the crew shall follow. The Garbage Management Plan is not being followed resulting in mixed garbage throughout the ship. Crew has disposed food waste overboard 15 times since last port which PSCE believes included paper and plastic, MARPOL V/10, 10c.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 September 2015
Resolved
1499-Other-PSCO observed electrical cable coming from back of switchboard in engine control room, penetrating through bulkhead and into electricians room, cable then penetrates through second bulkhead into main engine room where it powers air conditioning system inside electricians room. Request clarification from class attesting to installation.-SOLAS 74(a)I/11
Engineering › Freshwater Generation System › Piping
Issued 18 September 2015
Resolved
1499-Other-PSCO obsv hose coming from f/w generator and running along electrical cable runs through e/r and eventually ending in steering gear room where it was piped into f/w fill piping. C/E and Master stated existing f/w piping has severe internal corrosion and crew was spending extensive time cleaning f/w tanks. Request clarification from class attesting to installation-SOLAS 74(a) I/11
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.