This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it49982 - Dead Weight, Ton 31534 - Convention (Subpart B), Gross Ton 13395 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 2
4 May 2016Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5868623
8 April 2016ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5846483
Deck/Cargo › Inert Gas System › Gas Regulating Valve
Issued 8 April 2016Resolved
The IGS System shall be designed, constructed, and tested to the satisfaction of administration. Suitable means shall be provided for the zero and span calibration of 2.4.2.1 Fixed IGS gas analyzer. Ship could not provide technical drawing of IGS analyzer. PSC Officer undable to verify that IGS oxygen analyzer was installed IAW manufacturer guidelines. 74 SOLAS (04) II-2/4.5.5.3.2 FSS 15.2.1.2
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 May 2016
Resolved 4 May 2016
Resolution: Vessel provided proof that vessel has necessary plans and guidelines.
Electrical equipment of a type which will not ignite flammable mixtures on board tankers shall be installed in a spae where flammable mixtures are libale to collect. Light fixtures within the deck storage locker missing a cap fixture, light is no longer explosion proof. 74SOLAS(04)II-1/45.10 Rectify deficiency within 30 days.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 May 2016
Resolved 4 May 2016
Resolution: Vessel provided class approval of installation of correct light fixture.
Batteries shall be suitably housed and compartments used for their accomodation shall be properly constructed and efficiently ventilated. PSC Officers discovered batteries being stored improperly in a poorly ventilated compartment. 74 SOLAS (04) II-1/45.4.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 April 2016
Resolved 8 April 2016
Resolution: Vessel's crew moved batteries to appropriate storage.