Records from 2016 to 2025. Most recent: inspection, 21 January 2025.
Inspection history · 6
21 January 2025
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8066928
29 March 2022
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7420494
11 June 2018
ISPS II Exam · Deficiency Check · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6435615
10 May 2017
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6142753
8 October 2016
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6018782
14 March 2016
Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5832556
09 - Working and Living Conditions › 092 - Working Conditions › Gangway, accommodation-ladder
Issued 21 January 2025
No resolution recorded
For all ships, the means for embarking and disembarking shall be inspected and maintained in sutible condition for thier intended purpose, taking into account any restrictions related to safe loading. PSCO observed broken repair welds on the #2 and #3 steps of the embarkation ladder.
74SOLAS(20)II-1/3-9.3
40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 16 June 2018
Resolved
11135 - Maintenance of Lifesaving Equipment - All lifesaving appliances shall comply with the Code. Retro-reflective tape is worn and faded on all lifebuoys.
74SOLAS(14)III/34 - LSA 1.2.2.7
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 16 July 2018
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 11 June 2018
Resolved
07105 - Fire Doors - Doors required to be self-closing shall not be fitted with hold-back hooks. All boundary bulkhead doors in the galley were not self-closing and are required to be by the Fire Control Plan.
74SOLAS(14)II-2/9.4.2.2
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 16 July 2018
Resolution: Hold-back hooks removed.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boat inventory
Issued 11 June 2018
Resolved
11105 - Rescue Boat Inventory - Cargo ships shall carry at least one Rescue Boat complying with 5.1 of the Code. Search light on the Rescue Boat is inoperative.
74SOLAS(14')III/31.2 - LSA 5.1.2.2.11
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 16 July 2018
Lifesaving › Buoyant Smoke Signals › General
Issued 10 May 2017
Resolved
74SOLAS(14)III/34 LSA Code 4.4.8.15 All life saving appliances and arrangements shall comply with applicable requirements of the LSA Code. PSCO observed 02 required smoke signals missing from lifeboat.
Condition: Invalid
Due 24 May 2017
Resolved 16 July 2018
Resolution: Smoke signals o/b
Construction/Loadline › Markings › Load Line Mark
Issued 10 May 2017
Resolved
ICLL 66 Annex I/8 The ring, lines and letters shall be painted in white or yellow on a dark ground. PSCO observed ring, lines, and letters without paint of contrasting color.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 July 2018
Resolution: Load Line contrasting