Records from 2012 to 2026. Most recent: inspection, 21 May 2026.
Documentation record
Registered dimensions (L × B × D)238.7 ft × 64.5 ft × 23.5 ft
Registered tonnagegross 2,724 / net 1,403
ITC dimensions (L × B × D)238.7 ft × 64.5 ft × 23.5 ft
ITC tonnagegross 2,724 / net 1,403
BuilderZIDELL MARINE CORPORATION · PORTLAND, OR, UNITED STATES · built 2012
Hull materialSteel
PropulsionNone
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPORTLAND, OR
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 22 April 2026 · expires 31 May 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it2724 - Convention (Subpart B), Gross Ton
5329 - Dead Weight, Gross Ton
1403 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 29
21 May 2026
MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8350733
15 May 2025
Internal Structural Exam · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8136206
4 September 2024
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8009772
11 February 2023
Bulk Liquid Transfer Monitor
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7635488
6 June 2022
Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7470473
25 May 2022
Cargo Tank Internal · MARPOL Annex I Examination · Deficiency Check · COI Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7459191
29 July 2021
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7271855
4 July 2021
Bulk Liquid Transfer Monitor
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7244599
5 June 2021
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7220505
23 January 2021
Bulk Liquid Transfer Monitor
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7129577
27 July 2020
Annual Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7014086
7 October 2019
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6830049
26 September 2018
Annual Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6549558
9 August 2018
In-Service Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6506082
28 July 2017
COI Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6221328
30 September 2016
MARPOL Annex I Examination · MTSA/ISPS Verification · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6007553
29 November 2015
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5771677
16 September 2015
Internal Structural Exam · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5721291
2 June 2015
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5143189
2 April 2015
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5095722
26 July 2014
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4934538
14 July 2014
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4922244
19 January 2014
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4785693
8 December 2013
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4765932
9 November 2013
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4750127
12 October 2013
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4733811
26 August 2013
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4697533
17 July 2013
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4656461
2 August 2012
Initial Certification · Deficiency Check · Hull Examination · Cargo Tank Internal · MTSA Verification · MARPOL Annex I Examination · Construction Oversight · Internal Structural Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4333621
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 25 May 2022
Resolved
Any tank vessel which is equipped with an internal combustion engine driven cargo pump on the weather deck shall be provided with a minimum of one remote manual shutdown station. Vessel was unable to provide test pump internal combustion engine shutdowns.
46 CFR 32.50-35
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 August 2022
Resolved 18 August 2022
Resolution: Vessel was able to test internal combustion engine driven cargo pump, test satisfactory
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 29 July 2021
Resolved
Where cargo pump shafts pierce gastight bulkheads, stuffing boxes with readily accessible gastight glands shall be provided. The starboard and port gastight glands for the prime mover shafts were cracked.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 August 2021
Resolved 3 August 2021
Resolution: Received photographic evidence.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Gaskets
Issued 30 September 2016
Resolved
Install gaskets in bulkhead penetrations for port and starboard cargo pump shafts.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 October 2016
Resolved 30 September 2016
Resolution: Replaced gaskets.
Engineering › Diesel Engine (auxiliary) › Emergency shutdown
Issued 30 September 2016
Resolved
Prove proper operation of emergency shutdown for pump engines.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2016
Resolved 30 September 2016
Resolution: Serviced shutdowns, tested all sat.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 16 September 2015
Resolved
Conduct hydrostatic tests on cargo hoses.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 October 2015
Resolved 16 September 2015
Resolution: Conducted hydrostatic test of hoses.
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 16 September 2015
Resolved
Prove proper operation of PV valves for cargo tanks 4S and 5P.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 October 2015
Resolved 16 September 2015
Resolution: Serviced PV valves for cargo tanks 4S and 5P.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 16 September 2015
Resolved
Install pressure gauges on all cargo piping.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 October 2015
Resolved 16 September 2015
Resolution: Installed pressure gauges on all cargo piping.
Engineering › Diesel Engine (auxiliary) › Emergency shutdown
Issued 16 September 2015
Resolved
Prove proper operation of emergency shutdown for pump engine.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 October 2015
Resolved 16 September 2015
Resolution: Serviced emergency shutdown for pump engine.
Deck/Cargo › Vapor Control Systems › Vapor Recovery Unit
Issued 2 August 2012
Resolved
Vessel prohibited to use Vapor Control System until USCG MSC approved Cargo Authority Attachment is received by owner and delivered to local USCG OCMI.
Action required: 705 - Other - as specified
Due 2 September 2012
Resolved 20 August 2012