MAURY USCG vessel records
← All vessels

AMAZON

AMAZON is a 2011 tank ship. The Coast Guard has recorded 3 inspections since 2016, most recently in December 2024, along with 6 deficiencies — 2 with no resolution recorded —.

Records from 2016 to 2024. Most recent: inspection, 6 December 2024.

Built
2011
Last inspected
6 December 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 6 December 2024
…past their stated due date2
Operational controls None recorded without a removal date
Years with a record 2 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9476654
1155984
Flag
LIBERIA
Maury page id
psix-1155984

Documentation record

Tonnage as PSIX records it149999 - Dead Weight, Metric Ton
177471 - Displacement, Metric Ton
85496 - Convention (Subpart B), Gross Ton
47286 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 3

6 December 2024 PSC B · COC-TVE Renew · Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8043665
5 December 2024 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8043874
18 June 2016 Administrative Inspection · Ballast Water Examination · Deficiency Check · COC-TVE Renew · ISPS II Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 5910216

Deficiency record · 6

02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 December 2024 Resolved
IN TANKERS, ELECTRICAL EQUIPMENT, CABLES AND WIRING SHALL NOT BE INSTALLED IN HAZARDOUS LOCATIONS UNLESS IT CONFORMS WITH STANDARDS NOT INFERIOR TO THOSE ACCEPTABLE TO THE ORGANIZATION. PSCO OBSERVED MULTIPLE EXPLOSION PROOF LIGHTING FIXTURES MISSING PROPER GLANDS IN THE PUMP ROOM AND ON DECK. INTRINSIC AUDIBLE AND VISIUAL ALARM IN PUMPROOM NOT PROPERLY GROUNDED. 74SOLAS(2014)II-1/45.11
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 December 2024
Resolution: Recieved satisfactory Class Report.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 6 December 2024 Resolved
THE FIRE RESISTANCE OF DOORS SHALL BE EQUIVALENT TO THAT OF THE DIVISION IN WHICH THEY ARE FITTED, THIS BEING DETERMINED IN ACCORDANCE WITH THE FIRE TEST PROCEDURES CODE. DOOR AND DOOR FRAMES IN "A" CLASS DIVISIONS SHALL BE CONSTRUCTED OF STEEL. DOORS IN "B" CLASS DIVISIONS SHALL BE NON-COMBUSTIBLE. DOORS FITTED IN BOUNDARY BULKHEADS OF MACHINERY SPACES OF CATEGORY A SHALL BE REASONABLY GASTIGHT AND SELF-CLOSING. IN SHIPS CONSTRUCTED ACCORDING TO METHOD IC, THE ADMINISTRATION MAY PERMIT THE USE OF COMBUSTIBLE MATERIALS IN DOORS SEPARATING CABINS FROM INDIVIDUAL INTERIOR SANITARY ACCOMMODATION SUCH AS SHOWERS. PSCO OBSERVED THE FOLLOWING A-0 SELF CLOSING FIRE DOORS AS INDICATED ON THE FIRE CONTROL PLAN UNABLE TO PROPERLY CLOSE AND/OR FITTED WITH A HOLDBACK HOOK; CREW LAUNDRY, UPPER DECK AND A-DECK MAIN STAIRWELL, OFFICERS MESS, GALLEY, CREW AND ENGINE CHANGING ROOM, CAPTAIN'S PANTRY, CCR, AND STEERING GEAR TO ENGINE ROOM. 74SOLAS(2009)II-2/9.4.2.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 December 2024
Resolution: Recieved satisfactory Class Report.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 6 December 2024 Resolved
THE PURPOSE OF THIS REGULATION IS TO PREVENT THE IGNITION OF COMBUSTIBLE MATERIALS OR FLAMMABLE LIQUIDS. FOR THIS PURPOSE, THE FOLLOWING FUNCTIONAL REQUIREMENTS SHALL BE MET MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. PSCO OBSERVED OIL LEAKS AND OIL ACCUMULATION ON THE MAIN ENGINE FUEL PUMPS ON CYLINDERS 1,3,4,5 AND 6, ALONG WITH THE INJECTORS ON CYLINDERS 1 AND 5 AND IN BETWEEN CYLINDERS 4,5, AND 6. 74SOLAS(2009)II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2024
Engineering › Diesel Engine (propulsion-direct drive) › Nozzle, Injection (fuel injection)
Issued 18 June 2016 Resolved
1499-Other-The condition of the ship and its equip shall be maintained to conform with the provisions of the present regulations to ensure the ship in all respects remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed fuel line closed to ME fuel pump on cylinder #3. All other lines were open. Upon questioning CE stated the injector nozzle was leaking SOLAS I/11
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 18 June 2016
Resolved 20 June 2016
Resolution: Received, reviewed and accepted statement, pictures and documentation from Vessel Master stating the gasket for the injector nozzle was replaced, tested and found satisfactory.
Engineering › Lubricating Oil Storage/Transfer System › Piping
Issued 18 June 2016 No resolution recorded
0730-Appliances-The arrangements for the sorage distribution & utilization of oil used in pressure lubricating systems shall be such as to ensure the safety of the ship & persons on board. Sight glass lever was found tied in the open position on the #2 cylinder oil storage tank. SOLAS II-2/4.2.3.1
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 18 July 2016 — due date passed with no resolution recorded
Fire Fighting › Fixed Gas Fire Extinguishing System › Nozzle
Issued 18 June 2016 No resolution recorded
0725-Fixed Fire ext installation-Maintenance testing & inspections shall be caried out based on the guidelines developed by the organization & in a manner having due regard to ensuring the reliability of fire fighting systems & appliances. Tape was found covering CO2 nozzle over composite boiler. Monthly maintenance requires visual insp of discharge piping. Last insp was 06/06/16. SOLAS II-2/14.2
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 18 July 2016 — due date passed with no resolution recorded

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.