Records from 2016 to 2025. Most recent: inspection, 11 September 2025.
09 - Working and Living Conditions › 091 - Living Conditions › Cleanliness
Issued 20 November 2024
Resolved
Address what appears to be mold in the engine room near the forward bulkhead.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2025
Resolved 11 September 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 November 2024
Resolved
clean and descale engine and clean/replace air filter over transmission.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2025
Resolved 11 September 2025
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 6 September 2023
Resolved
Provide valid Certificate of Documentation prior to operating.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 October 2023
Resolved 7 September 2023
Resolution: Master stated application was filed and provided Pay.Gov receipt of Documentation and late fees.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 6 September 2023
Resolved
Prove operation of fireboy override restart feature.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2023
Resolved 16 October 2023
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 6 September 2023
Resolved
Prove operation of compass light. Vessel restricted to daylight operation only until corrected.
Action required: 705 - Other - as specified
Due 6 October 2023
Resolved 16 October 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 September 2023
Resolved
Replace bad 8D house/start battery.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2023
Resolved 16 October 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 September 2023
Resolved
Post PFD donning placard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2023
Resolved 28 September 2023
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 22 June 2022
Resolved
Provide invoice for fire equipment servicing.
Action required: 705 - Other - as specified
Due 22 June 2022
Resolved 22 June 2022
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 15 June 2022
Resolved
Repair or replace lifefloat. **Vessel restricted to not more than 1 mile from land until corrected/cleared**.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2022
Resolved 16 February 2023
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 15 June 2022
Resolved
Install paddles in lifefloat.
Action required: 705 - Other - as specified
Due 22 June 2022
Resolved 22 June 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 June 2022
Resolved
Replace expired waterlight batteries.
Action required: 705 - Other - as specified
Due 22 June 2022
Resolved 20 June 2022
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 15 June 2022
Resolved
Replace expred items in first aid kit.
Action required: 705 - Other - as specified
Due 22 June 2022
Resolved 20 June 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 June 2022
Resolved
Address water seal leakage on R/W pump.
Action required: 705 - Other - as specified
Due 22 June 2022
Resolved 24 June 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 June 2022
Resolved
Replace exhaust cooling water inlet hose.
Action required: 705 - Other - as specified
Due 22 June 2022
Resolved 20 June 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 June 2022
Resolved
Install supports on fuel valve manifold.
Action required: 705 - Other - as specified
Due 22 June 2022
Resolved 21 June 2022
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 June 2022
Resolved
Reove paint from vessel.
Action required: 705 - Other - as specified
Due 22 June 2022
Resolved 21 June 2022
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 15 June 2022
Resolved
Display vessel name on bow and transom.
Action required: 705 - Other - as specified
Due 22 June 2022
Resolved 22 June 2022
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 15 June 2022
Resolved
Secure all-around light stanchion.
Action required: 705 - Other - as specified
Due 22 June 2022
Resolved 22 June 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 June 2022
Resolved
Provide FCC Safety Certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2022
Resolved 11 October 2022
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 15 June 2022
Resolved
Log monthly checks and drills.
Action required: 705 - Other - as specified
Due 15 September 2022
Resolved 13 October 2022
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 15 June 2022
Resolved
Prove operation of compass light.
Action required: 705 - Other - as specified
Due 22 June 2022
Resolved 13 October 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 June 2022
Resolved
Address corrosion on gear box control cable.
Action required: 703 - Prior to bunkering operations
Due 22 June 2022
Resolved 22 June 2022
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 12 August 2020
Resolved
Provide DSC VHF Radio with MMIS #.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 September 2020
Resolved 4 September 2020
Resolution: Provided and tested sat.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 12 August 2020
Resolved
Float lights on Life Float and Ring Buoy have "terminal" type battery connections. Batteries installed are "spring" type connections. Batteries installed are not in accordance with approval for light. Provide approved batteries for float lights.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 September 2020
Resolved 4 September 2020
Resolution: Provided and tested sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 August 2020
Resolved
Band clamp connection turbocharge to exhaust discharge piping is broken allowing exhaust gas to escape into machinery space and not supporting the exhaust piping. Replace band clamp.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 12 August 2020
Resolution: Band clamp replaced with new.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 August 2020
Resolved
Main engine exhaust hose is dry rotted and showing signs of wear. Renew hose.
Action required: 705 - Other - as specified
Due 1 May 2021
Resolved 23 June 2021
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 12 September 2019
Resolved
Provide new paddles (2).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2019
Resolved 29 October 2019
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 12 September 2019
Resolved
Replace expired aspirin.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2019
Resolved 26 September 2019
Resolution: New First Aid Kit Provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 September 2019
Resolved
Replace expired waterlight batteries.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2019
Resolved 16 October 2019
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 15 June 2017
Resolved
Prove operation of fixed system override restart.
Action required: 705 - Other - as specified
Due 31 July 2017
Resolved 12 July 2017
Resolution: Proper operation was demonstrated.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 15 June 2017
Resolved
Provide ring buoy waterlight battery.
Action required: 705 - Other - as specified
Due 22 June 2017
Resolved 22 June 2017
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 15 June 2017
Resolved
Provide lifefloat waterlight battery.
Action required: 705 - Other - as specified
Due 22 June 2017
Resolved 22 June 2017
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 15 June 2017
Resolved
Replace expired alco-test kits.
Action required: 705 - Other - as specified
Due 22 June 2017
Resolved 22 June 2017
Resolution: New kits were purchased.
Communications › Audible Communications › Horn/Whistle
Issued 15 June 2017
Resolved
Prove operation of horn.
Action required: 705 - Other - as specified
Due 22 June 2017
Resolved 22 June 2017
Resolution: Portable horns purchased.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 15 June 2017
Resolved
Provide vent shutoff for starboard duct.
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 4 July 2017
Resolution: New damper fabricated/installed.
Fire Fighting › Structural - Horizontal Zones › General
Issued 15 June 2017
Resolved
Replace cracked skylight.
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 4 July 2017
Resolution: New skylight is in place.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 10 August 2016
Resolved
Prove operation of fixed system shutdown feature.
Action required: 705 - Other - as specified
Due 13 August 2016
Resolved 11 August 2016
Resolution: New control panel installed.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 10 August 2016
Resolved
Replace water hose and clamps on water hose, MDE.
Due 31 December 2016
Resolved 15 June 2017
Resolution: Attended vessel for COI. New hose in place.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 10 August 2016
Resolved
Repair halyard clip on port entryway rail.
Due 17 August 2016
Resolved 11 August 2016
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 10 August 2016
Resolved
Provide updated FCC safety Certificate.
Due 10 September 2016
Resolved 12 August 2016
Resolution: New FCC Cert issued.