Inspection history · 5
14 May 2024
PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7912097
28 December 2023
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7875439
13 November 2023
Ballast Water Examination · Deficiency Check · COC-GAS Renew · Administrative Inspection · PSC B
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7817887
2 June 2017
Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 6223840
27 May 2017
COC-GAS Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6153335
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 13 November 2023
Resolved
THE COMPANY SHOULD ESTABLISH PROCEDURES TO ENSURE THAT THE SHIP IS MAINTAINED IN CONFORMITY WITH THE PROVISIONS OF THE RELEVANT RULES AND REGULATIONS AND WITH ANY ADDITIONAL REQUIREMENTS WHICH MAY BE ESTABLISHED BY THE COMPANY. THE OBJECTIVE EVIDENCE OF THE DEFICIENCIES BELOW ALONG WITH THE LACK OF CREW REPORTING OF NON-CONFORMITIES AND TAKING APPROPRIATE CORRECTIVE ACTIONS BRINGS INTO QUESTION THE VALIDITY OF THE SAFETY MANAGEMENT SYSTEM AS REQUIRED IN THE ISM CODE. AN AUDIT IS REQUIRED TO BE SUBMITTED TO THE COAST GUARD PRIOR TO DEPARTURE.
74 SOLAS 20 IX / 3.1
ISM CODE PART A / 10.1,10.2
Action required: 30 - Ship detained
Due 13 November 2023
Resolved 21 November 2023
Resolution: Received and accepted external audit by DNV. Audit addressed all deficiencies and identified major non-conformity.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 November 2023
Resolved
WHERE ELECTRICAL EQUIPMENT IS INSTALLED IN GAS DANGEROUS SPACES OR ZONES AS PROVIDED IN 10.1.4 IT SHOULD BE TO THE SATISFACTION OF THE ADMINISTRATION AND APPROVED BY THE RELEVANT AUTHORITIES. DECK HAND OBSERVED DRILLING HOLES IN INTRINSICALLY SAFE LIGHTING ON DECK. SEVERAL DEAD ENDED WIRES AND LIGHT FIXTURES OBSERVED WITH MISSING OR BROKEN GROUNDING STRAPS. OBSERVED WATER INSTRUNSION IN OVER HALF OF LIGHTING FIXTURES ON DECK TO INCLUDE EMERGENCY LIGHTING FIXTURES.
74 SOLAS 20 VII / 13.1
IGC 10.1.5
Action required: 30 - Ship detained
Due 13 November 2023
Resolved 21 November 2023
Resolution: Observed all dead end wires, non explosion proof enclosures and lighting fixtures were rectified during vessel walk through with DNV.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 13 November 2023
Resolved
GAS DETECTION EQUIPMENT SHOULD BE SO DESIGNED THAT IT MAY READILY BE TESTED. SUITABLE EQUIPMENT AND SPAN GAS FOR THIS
PURPOSE SHOULD BE CARRIED ON BOARD. THE SPAN GAS FOR THE TESTING OF THE VESSEL'S PORTABLE GAS DETECTORS IS EXPIRED AND THE VESSEL IS UNABLE TO TEST ITS PORTABLE GAS DETECTION.
74 SOLAS 20 VII / 13.1
IGC 1993 13.6.6
Action required: 30 - Ship detained
Due 13 November 2023
Resolved 16 November 2023
Resolution: Witnessed satisfactory calibration of portable gas detector and alarm test of fixed gas detection system with newly purchased span gas.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 13 November 2023
Resolved
LOW TEMPERATURE PIPING SHOULD BE THERMALLY ISOLATED FROM THE ADJACENT HULL STRUCTURE WHERE NECESSARY TO PREVENT THE TEMPERATURE OF THE HULL FROM FALLING BELOW THE DESIGN TEMPERATURE OF THE HULL MATERIAL. THE WATER CURTAIN ON THE STARBOARD SIDE HAD TWO BROKEN BRACKETS THAT PREVENT THE WATER CURTAIN FROM ADEQUATELY PROTECTING THE HULL.
74 SOLAS 20 VII / 13.1
IGC 1993 5.2.1.3
Action required: 17 - Rectify deficiencies prior to departure
Due 13 November 2023
Resolved 21 November 2023
Resolution: Observed satisfactory repair made to water curtain. Functions as intended.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 13 November 2023
Resolved
THE WATER SPRAY SYSTEM SHALL BE CAPABLE OF UNIFORMLY DISTRIBUTING A WATER SPRAY. THE WATER SPRAY SYSTEM HAD MULTIPLE CLOSED SPRAY VALVES AND LEAKS IN THE FIRE MAIN.
74 SOLAS 20 VII / 13.1
IGC 1993 11.3.2
Action required: 30 - Ship detained
Due 13 November 2023
Resolved 16 November 2023
Resolution: Witnessed satisfactory test of water spray system.