KAPTAN ARIF BAYRAKTAR is a 2010 freight ship. The Coast Guard has recorded 2 inspections in 2014, along with 2 deficiencies and 2 operational controls.
Records in 2014. Most recent: operational control imposed, 16 October 2014.
The 2 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Share this recordDownload vessel cardDownload QRMaury, US Coast Guard vessel record for KAPTAN ARIF BAYRAKTAR, retrieved 18 September 2026. mauryrecords.com/v/psix-1156715.html
Documentation record
Tonnage as PSIX records it18900 - Convention (Subpart B), Net Ton 57453 - Dead Weight, Ton 68960 - Displacement, Ton 34509 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.
Inspection history · 2
16 October 2014PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5002210
12 October 2014Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5003957
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 16 October 2014Resolved
1799-Each no metallic hose must not burst, bulge or leak, or under abnormally distort under static liquid pressure are least 1 1/2 times the MAWP. Chief Engineer provided hydro static test records from 2010. Provide documentation attesting to the proper testing of transfer pipe system before conducting bunkering operations in US waters. 33 CFR 156.170
Action required: 705 - Other - as specified
Resolved 21 October 2014
Resolution: Received, reviewed and accepted proper documentation from Master satisfying the requirement. Vessel completed hydro static test of bunker lines complying with 33 CFR 156.170
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Valves
Issued 16 October 2014Resolved
0725- Fixed fire extinguishing installation- Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO observed the hyper-mist fixed fire-fighting system fresh water supply valve closed and the system in off position. provide corrective action plan from company with concurrence from the Administration. Cite SOLAS 74a II-2/14.2.1
Action required: 705 - Other - as specified
Due 16 October 2014
Resolved 17 October 2014
Resolution: Received, reviewed and accepted class report from [name withheld] stating the outstanding deficiency was rectified. Training was provided to the crew and warning placards were posted on critical components.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.