MAURY USCG vessel records
← All vessels

MISS MANATEE

MISS MANATEE is a 2004 passenger vessel (inspected). The Coast Guard has recorded 14 inspections since 2016, most recently in January 2026, along with 17 deficiencies and 1 operational control.

Records from 2016 to 2026. Most recent: inspection, 29 January 2026.

Built
2004
Last inspected
29 January 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 29 January 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

1156754
Flag
UNITED STATES
Maury page id
psix-1156754

Documentation record

Tonnage as PSIX records it1 - Simplified, Net Ton
1 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 14

29 January 2026 Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8288562
30 January 2025 Annual Inspection · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8050858
27 April 2024 Type not recorded
No type recorded · Station Crystal River · USCG Southeast District (CGD-SE) · Activity 7903258
8 February 2024 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7853454
23 February 2023 Annual Inspection · Deficiency Check · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7619463
12 January 2022 Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7369262
23 February 2021 Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7130753
26 January 2021 Drydock Exam · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7130749
4 February 2020 Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6884497
18 March 2019 Internal Structural Exam · Annual Inspection · Administrative Inspection · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6630741
18 January 2018 DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6339525
6 January 2017 COI Inspection · DAPI Audit · Administrative Inspection · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6067064
21 April 2016 DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5856439
15 April 2016 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5854959

Deficiency record · 17

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 January 2025 Resolved
Portable extinguishers must be inspected and maintained in accordance with NFPA 10. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. If any of the equipment or records have not been properly maintained, a qualified servicing facility must perform the required inspections. Inspector observed all extinguishers not serviced within 12 month period. 46CFR176.810(b)(1)(iv) 701c
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 January 2025
Resolved 30 January 2025
Resolution: Vessel provided photo's of portable fire ext. that were replaced and/or inspected satisfactory.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 January 2025 Resolved
The frame or support of each semi-portable fire extinguisher permitted by paragraph (a) of this section must be welded or otherwise permanently attached to a bulkhead or deck. Inspector observed support not permanently attached to a bulkhead. 46CFR181.500(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2025
Resolved 4 March 2025
Resolution: Provided photo of bracket secured to the deck.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 January 2025 Resolved
The design, construction, and stowage of portable tanks and related fuel lines and accessories must meet the requirements of ABYC H-25 (incorporated by reference; see 46 CFR 175.600) or other standard specified by the Commandant. Inspector observed fuel shut off valve leaking and unclear markings to identify if valve is closed. Replace fuel shut off valve. 46CFR182.458(b) 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2025
Resolved 4 March 2025
Resolution: Provided photo of new fuel valve mounted properly, with markings indicating location of fuel valve as well as direction of flow for ease of operation.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 30 January 2025 Resolved
At each inspection for certification and at every other vessel inspection all hazardous situations must be corrected and must be in satisfactory condition. Inspector observed cracks on ladder rungs. Requires repair when deck is replaced or within 6 months, which ever is sooner. 46CFR176.830(a) 705c 14AUG25: Worklist item is past original due date of 31JUL25. Converted to deficiency with new due date of 28AUG2025.
Action required: 705 - Other - as specified
Due 28 August 2025
Resolved 22 August 2025
Resolution: Received satisfactory photo evidence of weld repairs.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo ports and other similar openings
Issued 23 February 2023 Resolved
A hatch exposed to the weather must be watertight. Several inspection port plugs for pontoon hulls showed signs of damage or had mechanical failure (seizure of threads). Replace failing hull port plugs. 46 CFR 179.360(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 March 2023
Resolved 6 March 2023
Resolution: Received photos of newly installed pontoon hull plugs.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 February 2023 Resolved
Each battery must be located as high above the bilge as practicable.. and free from exposure to water splash or spray. Vessel battery box did not have a cover and contained 2-3 inches of standing water. Drain water from battery box and equip with a suitable cover. 46 CFR 183.350(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 March 2023
Resolved 6 March 2023
Resolution: Received photos of drained and covered battery box.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 January 2022 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. MI noted that fuel shutoff valve was not labeled. 46 CFR 185.608
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 January 2022
Resolved 19 January 2022
Resolution: Vessel representative labeled fuel shut off.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 January 2022 Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets and immersion suits. Child size life jacket stowage missing label. 46 CFR 185.604(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 January 2022
Resolved 19 January 2022
Resolution: Vessel representative labeled lifejacket stowage area.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 January 2022 Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. 02 of 03 portable fire extinguishers had not been serviced in over one year. 46 CFR 176.810(b)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 January 2022
Resolved 21 January 2022
Resolution: Vessel representative provided pictures of servicing stickers on 03 fire extinguishers.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 12 January 2022 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date U.S. Coast Pilot [name withheld] List, tide tables, and current tables. MI noted vessel was missing all listed publications. 46 CFR 184.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 January 2022
Resolved 13 January 2022
Resolution: Vessel representative purchased Coast Pilot [name withheld], and tide tables.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 January 2022 Resolved
Each life jacket must be marked with Type I retroreflective material. 02 adult size life jackets found with worn/ripped retroreflective tape. 46 CFR 185.604(h)
Action required: 10 - Deficiency Rectified
Due 12 January 2022
Resolved 12 January 2022
Resolution: Vessel representative replaced life jackets.
Fire Fighting › Remote Fuel Shutoff › General
Issued 18 January 2018 Resolved
Install fuel shutoff valve iaw 46CFR182.455(b)(4).
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 January 2018
Resolution: Shut-off valve installed prior to departure of marine inspectors.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 18 January 2018 Resolved
Install (1) A-II extinguisher iaw 46CFR181.500.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 January 2018
Resolution: Installed prior to the departure of marine inspectors.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 18 January 2018 Resolved
Install mount of B-I extinguisher iaw 46CFR181.520.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 January 2018
Resolution: Installed prior to the departure of the marine inspector.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 18 January 2018 Resolved
Install labels (# and adult/child) on PFD storage iaw 46CFR185.604(f)
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 2 February 2018
Resolved 18 January 2018
Resolution: Labels installed prior to departure of the marine inspectors.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 6 January 2017 Resolved
Owner missed hull exam date in accordance with his COI. 46CFR600
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 January 2017
Resolution: Owner [name withheld] exam.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 6 January 2017 Resolved
Owner missed renewal of COI. 46CFR176.107
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 January 2017
Resolution: Owner completed COI renewal.

Ownership record