Records from 2016 to 2026. Most recent: inspection, 23 June 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 13
23 June 2026
Hull Examination · COI Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8407294
14 May 2025
Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8140947
26 June 2024
Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7946753
24 May 2023
Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7706501
7 June 2022
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7478606
20 May 2021
Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7170033
31 July 2020
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7021278
10 June 2019
Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6709328
23 May 2019
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6685952
8 May 2018
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6402654
5 December 2017
Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6318918
12 April 2017
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6121331
3 August 2016
COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5954035
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 June 2026
No resolution recorded
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name...Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018 or other standard specified by the Commandant.
02 lifejackets had wasted retroreflective tape and 02 lifejackets didn't have proper vessel name marked on them. Provide new marking with vessel name ant retroreflective tape. Vessel is limited to 13 people total. 46CFR 185.604(b)&(h)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 June 2026
No resolution recorded
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced.
One of the lifejackets had wasted stitching. Repair or replace. Vessel is further limited to 12 people total. 46 CFR 176.808(b)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 23 June 2026
No resolution recorded
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have ... an audible alarm that sounds upon discharge. Engine compartment Fireboy audible activation alarm is inoperable. Resolve and prove proper operation of activation audible alarm to the satisfaction of the attending MI. 46 CFR 181.420(b)
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 23 June 2026
No resolution recorded
The alcohol testing of each individual must be conducted within 2 hours of when the SMI occurred. The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. The alcohol testing devices need not be carried on board each vessel if obtaining the devices and conducting the required alcohol tests can be accomplished within 2 hours from the time of occurrence of the SMI.
Alcohol test strips on board were expired. Vessel restricted to operations within a two hour transit of alcohol testing. 46 CFR 4.06-3, 46 CFR 4.06-15
Action required: 705 - Other - as specified
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 14 May 2025
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI.Alcohol test equipment was expired
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2025
Resolved 19 May 2025
Resolution: Test strips received and placed on board.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 23 May 2019
Resolved
A space containing propulsion machinery must be equipped with a gas fire extinguisher in compliance with 46CFR180.40. The Fire Boy onboard has not been serviced IAW manufacturer's instructions. Provide proof of servicing to attending Marine Inspector Prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 June 2019
Resolved 10 June 2019
Resolution: Received statement from Owner and servicing report from Advanced Fire Protection LLC indicating the installed Fire Boy Fire Suppression System underwent an annual inspection.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 23 May 2019
Resolved
An enclosed space containing machinery powered by Gasoline must be equipped with a vapor detection device in compliance with 46CFR182.480. The Vapor detection system onboard is inoperable. Prove proper operation of vapor detection system to the satisfaction of the attending Marine Inspector prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 June 2019
Resolved 10 June 2019
Resolution: Received video of Owner conducting Safety Function Check IAW manufacturers instructions. Fume detector works as designed.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 12 April 2017
Resolved
Prove proper operation of stern light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 May 2017
Resolved 18 May 2017
Resolution: Operator replaced bulb.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 12 April 2017
Resolved
Mark lifebuoy in accordance with 46CFR185.604.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 May 2017
Resolved 18 May 2017
Resolution: Operator labeled the lifebuoy in accordance with 46CFR185.604.