MAURY USCG vessel records Sign in
← All vessels

LMZ EUROPA

LMZ EUROPA is a 2011 freight ship. The Coast Guard has recorded 9 inspections since 2014, most recently in December 2024, along with 5 deficiencies and 1 operational control.

Records from 2014 to 2024. Most recent: inspection, 29 December 2024.

Built
2011
Last inspected
29 December 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9588562 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1157427
Flag
MARSHALL ISLANDS
—
Maury page id
psix-1157427

Inspections, by type

…with no type recorded3
Years with a record 6 calendar years (2014–2024)
The 9 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it19191 - Convention (Subpart B), Net Ton
56771 - Dead Weight, Metric Ton
67681 - Displacement, Metric Ton
32983 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 9

29 December 2024 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8051683
2 July 2024 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7940653
8 November 2023 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7821972
17 September 2019 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6821996
2 October 2018 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6552914
29 September 2018 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6551461
26 September 2018 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6549411
10 November 2015 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5756215
19 March 2014 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4806429

Deficiency record · 5

07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 2 July 2024 Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met: Means shall be provided to control the leaks of flammable liquids. PSCO observed accumulation of fuel oil on the main diesel engine and aassociated piping.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 5 July 2024
Resolution: Received class report from BV
Fire Fighting › Ventilation Systems › Fans
Issued 10 November 2015 Resolved
0799-Fire fighting appliances (Other) Controls provided for the power ventilation servicing machinery spaces shall be grouped so as to be operable from two positions, one of which shall be outside such spaces. CO2 control box for Emergency Generator is equipped w/ pressure switch designed to stop vent fan. System instructions & configuration don't support operation. SOLAS (14) II-2/5.2.2.2
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 December 2015
Resolved 12 November 2015
Resolution: Recieved class report that identifed two remote shut off locations after investigation. Crew was trained on new procedures for securing ventilation.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 10 November 2015 Resolved
0750- Fire fighting appliances (Fire prevention) Waste receptacles shall be constructed of non-combustible materials with no openings in the sides or bottom. Ship's crew is utilizing a wooden container for the storage of oil soaked rags in the engineering workshop. SOLAS (14) II-2/4.2
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 10 November 2015
Resolution: Ship's crew produced a metal receptacle while PSCO's on board the vessel.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 5 March 2014 Resolved
2120 - Garbage Recordkeeping - Discharge of all garbage in the sea is prohibited. Vessel discharged domestic waste, a garbage that is prohibited to be discharged into the sea. The discharges were recorded in the vessel's garbage log book and indicated 53 separate discharges beginning on September 15, 2013. - MARPOL Annex V/Reg 3.1(Res MEPC.201(62))
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 April 2014
Resolution: Vessel submitted Class report of survey conducted while in the port of Houston. A new log book has been implemented and training was conducted to ensure crew familiarity with MARPOL regs concerning the proper disposal and documentation of all Garbage.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 5 March 2014 Resolved
0720 - Maintenance, testing and inspection shall be carried out based on the guidelines developed by the organization(MSC.1/Circ 1432). # sets of CO2 pilot cylinders, one outside the purifiers, one at FS#1, and one in the CO2 control/storage showed expired exam stickers. Vessel did not have paperwork to show date of last inspection. - 74 SOLAS 09 con. II-2 Reg. 14.2.2.1
Action required: 705 - Other - as specified
Due 2 April 2014
Resolved 31 March 2014
Resolution: Received, Revieved and accepted report from Technician satisfying requirement.