← All vessels
RED FIN
RED FIN is a 2010 freight ship. The Coast Guard has recorded 12 inspections since 2015, most recently in April 2025, along with 6 deficiencies and 2 operational controls.
Records from 2015 to 2025. Most recent: operational control imposed, 28 April 2025.
- Built
- 2010
- Last inspected
- 28 April 2025
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 6 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9607306 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9HA2892
1158343
Flag
MALTA
—
Maury page id
psix-1158343
Inspections, by type
…with no type recorded2
Years with a record
7 calendar years (2015–2025)
The 12 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it19132 - Convention (Subpart B), Net Ton
33042 - Convention (Subpart B), Gross Ton
56773 - Dead Weight, Metric Ton
67681 - Displacement, Metric Ton
33042 - Convention (Subpart B), Gross Ton
56773 - Dead Weight, Metric Ton
67681 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 12
28 April 2025
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8121499
4 September 2024
PSC A
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7991478
28 August 2024
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7991511
18 January 2022
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7374388
26 June 2019
Administrative Inspection · PII Safety Exam · Deficiency Check · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6720113
26 June 2019
Type not recorded
No type recorded · Station Port Aransas · USCG Heartland District (CGD-H) · Activity 6728392
25 June 2019
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6725155
21 June 2019
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6721537
30 April 2018
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6402454
17 May 2017
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6142538
11 March 2017
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6097793
14 November 2015
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5763350
Deficiency record · 6
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 January 2022
Resolved
The rating or appropriate setting of the overload protective device for each circuit shall be permanently indicated at the location of the protective device. PSCO observed "water mist control" breaker in the off position, C/E stated breaker is a spare. PSCO also oberved five spare breakers in the ON position on the emergency switchboard. Recommend C/E, Electrician, and Class ensure all breakers are properly labelled.
74 SOLAS (14) II-1/45.6.2
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 26 June 2019
Resolved
Fire-fighter's outfits shall comply with the Fire Safety Systems Code. All four fire-fighter's outfits onboard are deteriorated around the outfit's stitching. Crew had identified company one month ago concerning the outfit's condition.
74 SOLAS (2014) II-2/10.1.1 - 17 a/c
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 June 2019
Resolved
The arrangements for the storage, distribution and utilization of oil used in pressure lubrication systems shall be such as to ensure the safety of the ship and persons onboard. Multiple large storage tanks of cylinder oil are being stored on an open deck, aft of accomodation on "A" Deck.
74 SOLAS (2014) II-2/4.2.3.1 - 17 a/c
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 11 March 2017
Resolved
1581-Rudder angle indicator-The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The rudder angle indicator in emergency steering is non functional. 74SOLAS(14 Cons.)I-11(A)-40ac
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 11 March 2017
Resolved
0725-Fixed fire extinguishing installation-Fire fighting systems and appliances shall be kept in good working order and readily available of immediate use. Four(04) CO2 bottles located near the stern air vent showed signs of corrosion at the bottle fitting points the manifold fitting points and on the actuator. 74SOLAS(09 Cons.)II-2/14.2.2.1.2-40ac
Engineering › Freshwater Generation System › Piping
Issued 11 March 2017
Resolved
9900-Other-After any survey of the ship under regulations 7,8,9 or 10 has been completed no change shall be made to the structural arrangements, machinery, equipment and other items covered by the survey without the sanction of the administration. Weld was located on the salt water intake for the fresh water generator. 74SOLAS(14 Cons.)I-11(b)-40ac
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.