This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
The counts in the strip above are the same counts; this table splits the inspections by
the kind of activity recorded. A blank resolution means none was recorded in this data; it
does not establish that a deficiency is outstanding. Years with a record are calendar
years in which a record exists, not years in service.
What Maury does not do.
Documentation record
Tonnage as PSIX records it27675 - Convention (Subpart B), Net Ton 87340 - Dead Weight, Metric Ton 102084 - Displacement, Metric Ton 47984 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 1
24 November 2021PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7348271
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 November 2021Resolved
The machinery, associated piping systems, and fittings shall be of a design and contruction adequate for the service for which they are intended and shall be so installed and protected as to replace to a minimum any danger to persons on board.The aft fuel injector for M.E. cylinder six found leaking.
13199 machinery
74SOLAS(20) II-1/26
60ac Prior to Movement
Action required: 60 - Rectify deficiencies prior to movement
Resolved 24 November 2021
Resolution: Received, reviewed and accepted class report. Injector replaced by crew and tested by class surveyor no leaks found.