MAURY USCG vessel records
← All vessels

LIVADI

LIVADI is a 2011 freight ship. The Coast Guard has recorded 21 inspections since 2016, most recently in April 2026, along with 5 deficiencies and 1 operational control.

Records from 2016 to 2026. Most recent: inspection, 18 April 2026.

Built
2011
Last inspected
18 April 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 18 April 2026
…with no type recorded5
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9522946
V7A2750
1158806
Flag
MARSHALL ISLANDS
Maury page id
psix-1158806

Documentation record

Tonnage as PSIX records it11719 - Convention (Subpart B), Net Ton
33232 - Dead Weight, Metric Ton
41520 - Displacement, Metric Ton
21934 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 21

18 April 2026 COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8351843
3 March 2026 PSC B · COE-Administrative
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8319252
9 February 2026 COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8307911
9 September 2025 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8230432
24 June 2024 Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7941350
7 June 2024 PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7924012
5 December 2023 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7833855
1 December 2023 COE-Administrative
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7832227
17 June 2022 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7480344
14 June 2022 PSC B
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7469633
6 June 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7470513
29 July 2021 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7271391
15 January 2021 COE-Offshore
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7124007
15 January 2021 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7125005
11 January 2021 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7122860
22 October 2020 Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7082270
20 October 2020 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7080670
24 February 2019 ISPS II Exam · COE-Dockside · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6626645
21 February 2018 COE-Offshore · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6356534
1 May 2017 PII Safety Exam · COE-Dockside · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6131515
16 September 2016 COE-Offshore
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5997661

Deficiency record · 5

03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 7 June 2024 Resolved
ALL EXTERNAL OPENINGS LEADING TO COMPARTMENTS ASSUMED INTACT IN THE DAMAGE ANALYSIS, WHICH ARE BELOW THE FINAL DAMAGE WATERLINE, ARE REQUIRED TO BE WATERTIGHT. PSCO OBSERVED DOOR LEADING FROM THE STEERING GEAR TO THE MAIN DECK TO NOT BE WATERTIGHT. 70SOLAS(20) II-1/ REG 15-1.1 16AC
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2024
Resolved 10 June 2024
Resolution: Recieved class report attesting to proper operation.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 7 June 2024 Resolved
FIRE-FIGHTING SYSTEMS AND APPLIANCES SHALL BE KEPT IN GOOD-WORKING ORDER AND READILY AVAILABLE FOR IMMEDIATE USE. PSCO OBSERVED OUTLET VALVE IN A CLOSED POSITION MAKING THE EMERGENCY FIRE PUMP NOT READILY AVAILABLE. 70SOLAS(20) II-2/REG 14-2.1.2 16AC
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2024
Resolved 10 June 2024
Resolution: Recieved class report ttesting to proper operation.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 7 June 2024 Resolved
FIRE DOORS IN GALLEY BOUNDARIES SHALL NOT HAVE HOLD BACK HOOKS WHICH ARE NOT SUBJECT TO CENTRAL CONTROL STATIONS OR RELEASE. PSCO OBSERVED 05 HOLD BACK HOOKS NOT SUBJECT TO CENTRAL CONTROL STATION RELEASE. 70SOLAS(09) II-2/REG 9.4.1.1.4.4. 10C
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 7 June 2024
Resolved 7 June 2024
Resolution: CREW REMOVED THE 05 HOLD BACK HOOKS NOT SUBJECT TO CENTRAL CONTROL STATION RELEASE.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 7 June 2024 Resolved
HYDRAULIC POWER-OPERATED STEERING GEAR SHALL BE PROVIDED WITH A FIXED STORAGE TANK HAVING SUFFICIENT CAPACITY TO RECHARGE AT LEAST ONE POWER ACTUATING SYSTEM INCLUDING THE RESERVOIR. PSCO OBSERVED THE FIXED STORAGE TANK NOT HAVING THE CAPACITY TO RECHARGE AT LEAST ONE POER ACTUATING SYSTEM INCLUDING THE RESERVOIR 70SOLAS(20) II-1/ REG 29.12.3. 10C
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 7 June 2024
Resolved 7 June 2024
Resolution: CREW FILLED FIXED STORAGE TANK WITH ENOUGH CAPACITY TO RECHARGE AT LEAST ONE POWER ACTUATING SYSTEM INCLUDING THE RESERVOIR.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 20 October 2020 Resolved
The ring, lines, and letters shall be painted in white or yellow on a dark ground or in black on a light ground, and be perminantly marked. The ring, lines, and letters on the port side of the vessel are badly rusted and no longer white or yellow on a dark ground, and do not match the vessel's Load Line Certificate due to being bent on the Winter Load Line.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 October 2020
Resolution: The vessel submitted pictures potraying sufficeint repairs.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.