LAMBI is a 2011 freight ship. The Coast Guard has recorded 13 inspections since 2012, most recently in February 2026, along with 3 deficiencies and 1 operational control.
Records from 2012 to 2026. Most recent: inspection, 20 February 2026.
- Built
- 2011
- Last inspected
- 20 February 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 3 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9595254 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7A2738
1158808
Flag
MARSHALL ISLANDS
—
Maury page id
psix-1158808
Inspections, by type
…with no type recorded1
Years with a record
8 calendar years (2012–2026)
The 13 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it11719 - Convention (Subpart B), Net Ton
35047 - Dead Weight, Ton
43346 - Displacement, Ton
21934 - Convention (Subpart B), Gross Ton
35047 - Dead Weight, Ton
43346 - Displacement, Ton
21934 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 13
20 February 2026
COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8313349
5 January 2026
PSC B
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8289213
12 January 2024
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7848619
9 November 2023
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7822846
17 January 2023
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7622331
6 July 2022
PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7497550
25 September 2020
PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7064945
24 September 2020
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7064056
18 April 2017
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6388567
27 January 2017
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6078203
28 October 2015
Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5752664
20 October 2015
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5740017
2 February 2012
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4232208
Deficiency record · 3
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 6 July 2022
Resolved
The ring, lines and letters shall be painted in white or yellow on a dark ground or in black on a light ground. PSCO observed two deck lines painted white on port side and starboard side load line was not painted.
ICLL (66)I/8
12AUG2022: Conducted Deficiency Check for M/V LAMBI at Sector San Francisco. Received photos confirm that 01 deficiencies have been rectified to Class satisfaction. Load lines are now painted. 01 Deficiencies cleared from activity #7497550 / 00 remain outstanding. Exam complete.
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 20 October 2015
Resolved
Where the emergency source of electrical power is a generator, it shall be started automatically upon failure of the main source of electrical power supply unless a transitional source of emergency electrical power in accordance with 3.1.3 is provided. PSCO observed emergency generator unable to start automatically due to low voltage in the battery bank.
Accommodation/Occupational Safety › Messroom › Location
Issued 20 October 2015
Resolved
Fire integrity at the divisions shall be maintained at openings and penetrations. PSCO observed hold back devices on self closing doors.