← All vessels
LEONA B
LEONA B is a 1972 towing vessel. The Coast Guard has recorded 19 inspections since 1993, most recently in October 2025, along with 23 deficiencies.
Records from 1993 to 2025. Most recent: inspection, 9 October 2025.
- Built
- 1972
- Last inspected
- 9 October 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 23 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
541529
WDN2346
115964
Flag
UNITED STATES
368261230
Maury page id
psix-115964
Inspections, by type
…with no type recorded7
Years with a record
13 calendar years (1993–2025)
The 19 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.
Documentation record
Registered dimensions (L × B × D)59.8 ft × 24.1 ft × 10.3 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWEAVER SHIPYARDS · ORANGE, TX, UNITED STATES · built 1972
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMILWAUKEE, WI
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 28 August 2026 · expires 30 September 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it67 - Regulatory (Subpart C or D), Net Ton
99 - Regulatory (Subpart C or D), Gross Ton
99 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDN2346MMSI 368261230 · active · voluntarily equipped · granted 9 June 2022, expires 9 June 2032
WDH7033MMSI 367644080 · expired · compulsorily equipped · granted 16 October 2014, cancelled 21 December 2024
WDB9652MMSI 366980350 · expired · compulsorily equipped · granted 28 September 2004, cancelled 29 November 2014
WAW5723MMSI not assigned · expired · compulsorily equipped · granted 25 June 1998, cancelled 30 August 2008 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspected as a tow unit · 2
The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.
AT 2400 Tank Barge · MISLE 50784 · 11 January 2001 · activity 102612MEM 1522 Freight Barge · MISLE 335939 · 8 May 1993 · activity 65715Inspection history · 19
9 October 2025
Annual Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 8249953
29 October 2024
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8026627
17 October 2024
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8020296
11 January 2024
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7848422
20 November 2023
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7827312
7 June 2023
Examination of Repairs · Construction Oversight · Administrative Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7719870
19 July 2022
Initial Certification · Deficiency Check
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 7483473
4 February 2014
Type not recorded
No type recorded · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 4794028
27 November 2012
Type not recorded
No type recorded · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 4491092
28 August 2012
Industry Initiated Exam
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 4423909
9 January 2008
Type not recorded
No type recorded · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 3127380
29 December 2006
Administrative Inspection
Administrative · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 2847713
5 December 2006
Administrative Inspection
Administrative · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 2834431
26 September 2006
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2787242
8 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1961053
11 September 2002
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1680522
11 January 2001
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 102612
30 June 1997
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 101874
8 May 1993
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 65715
Deficiency record · 23
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 October 2024
Resolved
(d)The valve must be operable from a safe place outside the space where the valve is installed.
Remote fuel shutoff valve inoperable due to cable binding.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 October 2024
Resolved
(a) All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid, as those terms are defined in 46 CFR subpart 30.10, into the machinery space.
Starboard fuel tank man hole cover is leaking fuel.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 17 October 2024
Resolved
Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into such spaces.
Port engine room ventilation intake cover does not close.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 October 2024
Resolved
(b) Each towing vessel must perform the applicable tests in Table 143.245(b) of this section. The tests required by this section must be recorded in accordance with part 140 of this subchapter.
Vessel representative was unable to provide records of alarm setpoint testing.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 17 October 2024
Resolved
(d) Weekly inspections and tests. (1) Each survival craft, rescue boat, and launching appliance must be visually inspected to ensure its readiness for use.
Liferaft painter was improperly attached to hydrostatic release weak link.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 November 2023
Resolved
Make repairs to or replace crack in STBD propulsion engine muffler.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 November 2023
Resolved
Replace PORT side fire hose due to rupture.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 27 November 2023
Resolved
Fuel oil emergency shut-off pull does not work properly.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 November 2023
Resolved
Payton Heater outlet box in FWD storage needs knock out hole filled with plug.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 27 November 2023
Resolved
Machinery space ventilation closure hardware is painted over and seized. Restore to proper operation.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 27 November 2023
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 27 November 2023
Resolved
All expired items in vessel industrial type first aid cabinet need to be replaced.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 27 November 2023
Resolved
Deck between the PORT FWD tow bits is wasted. Make repairs to the deck to ensure watertighness.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 November 2023
Resolved
Engine room electrical j-box in overhead is missing cover plate. Replace cover plate.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 November 2023
Resolved
Wire nuts are being used in electrical j-box in engine space overhead. If using wire nuts, use method to prevent them from coming loose through vibration.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 November 2023
Resolved
Finish insulation install for all engine and genset exhaust manifolds that exceed 428F.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 November 2023
Resolved
All new cable run installations need to be mounted with metal at least every 48".
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 14 November 2023
Resolved
Vessel is overdue for annual inspection. Perform annual inspection with local OCMI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 14 November 2023
Resolved
Vessel must perform alarm testing for gensets.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 July 2022
Resolved
All owners and operators of an existing towing vessel must have onboard a valid COI prior to the specified phase-in period. This vessel has not completed an inspection or obtained a valid COI. The vessel shall be made available for a Coast Guard COI inspection immediately and the vessel is no longer be permitted to operate.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 July 2022
Resolved
Portable fire extinguishers must be secured in the respective location with an approved bracket.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 19 July 2022
Resolved
Hose at fire station Port side weather deck was not properly threaded onto the pipe due to reversed pipe to hose coupling
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 19 July 2022
Resolved
Remove excess oil accumulation in engine room bilge and properly dispose of same.