← All vessels
ARGO B
ARGO B is a 2010 freight ship. The Coast Guard has recorded 15 inspections since 2012, most recently in May 2026, along with 5 deficiencies and 5 operational controls.
Records from 2012 to 2026. Most recent: inspection, 26 May 2026.
- Built
- 2010
- Last inspected
- 26 May 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 5 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9459371 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7TY5
1160054
Flag
MARSHALL ISLANDS
—
Maury page id
psix-1160054
Inspections, by type
…with no type recorded2
Years with a record
9 calendar years (2012–2026)
The 15 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it22402 - Convention (Subpart B), Gross Ton
12019 - Convention (Subpart B), Net Ton
35315 - Dead Weight, Metric Ton
44731 - Displacement, Metric Ton
12019 - Convention (Subpart B), Net Ton
35315 - Dead Weight, Metric Ton
44731 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 15
26 May 2026
PSC B
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8380452
11 September 2024
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8000394
10 September 2024
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 8000306
28 May 2024
PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7921322
8 November 2023
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7822160
22 August 2022
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7541086
5 April 2021
PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7165534
1 October 2019
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6825273
23 November 2018
Deficiency Check · COE-Dockside
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6582484
18 November 2018
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6582663
21 March 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6377265
15 March 2018
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6369455
14 March 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6373899
2 January 2016
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5789824
23 February 2012
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4249678
Deficiency record · 5
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 26 May 2026
Resolved
No change shall be made in the structural arrangement, machinery, equipment and other items covered by the survey, without the sanction of the administration. PSCO discovered emergency generator battery charger inoperable, being supplemented by a rolling stand alone battery charger, fitted to the generator batteries with alligator clips. Class documentation could not be presented.
74SOLAS(04) I/11b
60ac
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 September 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The vessel self reported a fuel leak from the M/E fuel pump causing reduced RPM's during the inbound transit to Kinder Morgan ERT.
74SOLAS(20)I/11(a)
60ac
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 September 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO received class report attesting to partial repairs to the M/E fuel pump No 3 and a fuel leak was observed while conducting operational testing.
74SOLAS(20)I/11(a)
17ac
Fire Fighting › Fixed Fire Detection System › UL 217 Approval
Issued 15 March 2018
Resolved
0715-Detection-All other types of cargo spaces shall be fitted with either a fixed fire detection and fire alarm system or a sample extraction smoke detection system ecomplying with the requirements of the Fire Safety System Code. PSCO observed fault on lines 1, 3 and 4 for sample extraction smoke detection system. Vessel is prohibited from carrying cargoes which require smoke detection as referenced in table 19.3 of chapter II-2. SOLAS 74(a) 2014 cons. II-2/19.3.3 ac
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 3 January 2016
Resolved
1740- The 15 PPM bilge alarm recording device should store data for at least 18 months and should be able to display or print a protocol. The crew was unable to display or print historical data. Demonstrate familiarity and proper operation of recording device. MARPOL 73/78 Regulation 6; MEPC 107 (49)
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.