MAURY USCG vessel records
← All vessels

SKY WALKER

SKY WALKER is a 2012 passenger vessel (inspected). The Coast Guard has recorded 18 inspections since 2016, most recently in April 2026, along with 24 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 30 April 2026.

Built
2012
Last inspected
30 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDG2627
1160144
Flag
UNITED STATES
Maury page id
psix-1160144

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)34.3 ft × 10.5 ft × 6.0 ft
Registered tonnagegross 14 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOMMERCIAL WATER SPORTS INC · CAPE MAY COURT HOUSE, NJ, UNITED STATES · built 2012
Hull materialFRP (Fiberglass)
PropulsionDiesel Direct
Hull shapeShip
Hull configurationMonohull
Hailing portKEY WEST, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 10 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it14 - Simplified, Gross Ton
11 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 18

30 April 2026 Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8358504
1 November 2025 Internal Structural Exam · Examination of Repairs · Administrative Inspection · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8270841
6 February 2025 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8075505
2 May 2024 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7898305
10 October 2023 Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7806936
1 February 2023 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7628191
18 July 2022 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7510085
4 February 2022 COI Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7384536
4 October 2021 Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7272610
3 February 2021 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7054437
3 February 2020 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6797494
11 October 2019 Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6799627
25 February 2019 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6571049
5 January 2018 Drydock Exam · Deficiency Check · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6346506
8 December 2017 Administrative Inspection · Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6348007
6 February 2017 COI Inspection · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6083557
9 February 2016 Annual Inspection · Deficiency Check · DAPI Audit · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5811237
6 January 2016 Drydock Exam · Administrative Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5795695

Deficiency record · 24

07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 30 April 2026 Resolved
Provide a means to secure all ventilation ducts to the engine compartment prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 April 2026
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 30 April 2026 Resolved
Provide a visual alarm for the forward bilge high level alarm (audible alarm is operational).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2026
Resolved 30 April 2026
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 30 April 2026 Resolved
Mark the life jacket stowage locations with the number and identification of life jackets stowed inside in numbers and letters at least 2" high (15 Adult Life Jackets).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2026
Resolved 11 May 2026
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 November 2025 Resolved
The vessel did not complete its required Drydock Exam and Internal Structural Exam within the required two-year timeline.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 November 2025
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 4 February 2022 Resolved
Replace/repair extinguished starboard navigation light.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 February 2022
Resolved 8 February 2022
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 4 February 2022 Resolved
Provide emergency broadcast placard at steering console.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 February 2022
Resolved 8 February 2022
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 February 2022 Resolved
Provide appropriately sized fire buckets.
Action required: 10 - Deficiency Rectified
Due 4 February 2022
Resolved 4 February 2022
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 4 February 2022 Resolved
Replace expired materials in First Aid Kit.
Action required: 10 - Deficiency Rectified
Due 4 February 2022
Resolved 4 February 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 March 2020 Resolved
Replace marine engine cooling hoses that were found collapsed and torn at connection. Hose from heat exchanger to engine pump, and hose for exhaust cooling.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 March 2020
Resolution: Hoses replaced
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 11 October 2019 Resolved
Repair soft spot on Starboard Aft hull below the water line, submit repair proposal to include material type (Glass type, weight, and resin). Area must be properly prepped and ground down to good glass prior to carrying out repairs.
Action required: 705 - Other - as specified
Resolved 7 November 2019
Resolution: repaired soft spot
Construction/Loadline › Hull › Bottom Plating
Issued 5 January 2018 Resolved
Make repairs to identified areas on port side of hull.
Action required: 705 - Other - as specified
Resolved 10 January 2018
Resolution: Repaired hull.
Communications › Radio Communications › EPIRB
Issued 8 December 2017 Resolved
Provide EPIRB with valid registration.
Action required: 705 - Other - as specified
Due 15 December 2017
Resolved 8 December 2017
Resolution: Provided new EPIRB and proof of registration.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 8 December 2017 Resolved
Provide means to secure air vents to engine room.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 December 2017
Resolution: Vessel lubricated release mechanism and demonstrated proper operation of closure.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 8 December 2017 Resolved
Provide 60 feet of line for life ring.
Action required: 705 - Other - as specified
Due 15 December 2017
Resolved 14 December 2017
Resolution: Attached 60 feet of bouyant line to life ring.
Communications › Radio Communications › EPIRB
Issued 8 December 2017 Resolved
Place valid registration decal on EPIRB
Action required: 705 - Other - as specified
Due 15 December 2017
Resolved 14 December 2017
Resolution: Affixed valid registration decal on EPIRB.
Construction/Loadline › Penetrations › Gasket
Issued 6 February 2017 Resolved
Fix gaskets on both deck hatches
Condition: Improper/Lack of Maintenance
Due 7 March 2017
Resolved 27 March 2017
Resolution: Replaced gaskets
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 6 February 2017 Resolved
Fill pipes on port/stbd fuel tanks were not properly grounded
Due 7 March 2017
Resolved 5 April 2017
Resolution: Vessel bonded fill pipes and tanks to common ground.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 6 February 2017 Resolved
Vessel did not have complete first aid kit as required
Due 7 March 2017
Resolved 27 March 2017
Resolution: Vessel purchased new approved first aid kit
Documentation › Markings/Placards › Garbage Placard
Issued 6 February 2017 Resolved
Vessel did not have garbage placard onboard/posted
Due 7 March 2017
Resolved 27 March 2017
Resolution: Posted placard
Documentation › Markings/Placards › Lifejacket Placard
Issued 6 February 2017 Resolved
Required vessel to post lifejacket donning placard
Due 7 March 2017
Resolved 27 March 2017
Resolution: Posted placard
Communications › Radio Communications › VHF Radiotelephone
Issued 6 February 2017 Resolved
Vessel required to input MMSI number and GPS capability into radio
Due 7 March 2017
Resolved 27 March 2017
Resolution: Installed new radio with internal GPS
Communications › Radio Communications › VHF Radiotelephone
Issued 9 February 2016 Resolved
Program MMSI # into Digital Select Calling VHF radio. FCC.
Action required: 705 - Other - as specified
Due 9 March 2016
Resolved 4 March 2016
Resolution: MMSI # 367517560 was programmed into DSC VHF radio.
Engineering › Bilge Water Management System › Interface Detector
Issued 9 February 2016 Resolved
Install visual indicator at operating to indicate when each automatic submersible bilge pump is operating.
Action required: 705 - Other - as specified
Due 9 March 2016
Resolved 4 March 2016
Resolution: Vessel installed visual indicator at operating station for each automatic submersible bilge pump.
Construction/Loadline › Structures › Deck Plating
Issued 6 January 2016 Resolved
Swim platform on the stern of the vessel is corroded through in some parts. Required owner to repair prior to credit drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 January 2016
Resolved 8 January 2016
Resolution: Wasted portions were cropped out and renewed.

Ownership record