Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
The counts in the strip above are the same counts; this table splits the inspections by
the kind of activity recorded. A blank resolution means none was recorded in this data; it
does not establish that a deficiency is outstanding. Years with a record are calendar
years in which a record exists, not years in service.
What Maury does not do.
Documentation record
Tonnage as PSIX records it64769 - Convention (Subpart B), Gross Ton 36935 - Convention (Subpart B), Net Ton 115499 - Dead Weight, Ton 134306 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 2
10 April 2025Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8109675
19 November 2024PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8036821
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 19 November 2024Resolved
The machinery, boilers and other pressure vessels, .associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts,hot surfaces and other hazards. PSCO observed multiple pipes in the engine room that connect to the M/E were found to be missing lagging and soaked in oil.
74SOLAS(20)II-1/26.1
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 November 2024Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO observed 02 fire hydrants on starboard side and 01 on the port side on the main deck leaking.
74SOLAS(20)II-2/14.2.1.2
Action required: 10 - Deficiency Rectified
Resolved 19 November 2024
Resolution: Vessel crew repaired leaking hydrant's. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 19 November 2024Resolved
Fire doors in main vertical zone bulkheads galley boundaries and stairs enclosers other than power operated watertight doors shall satisfy the following requirements. The doors shall be self closing with angle of inclination of up to 3.5° opposing closure. PSCO observed a self closing "A" class door at the galley that did not latch.
74SOLAS(20)II-2/9.4.1.1.5.1
Action required: 10 - Deficiency Rectified
Resolved 19 November 2024
Resolution: Vessel crew replaced door latch. All sat.