CORAL QUEEN II
Passenger (Inspected) · Passenger Ship class · Built 2000s · USCG Southeast District (CGD-SE) · Other hulls named CORAL QUEEN II
CORAL QUEEN II is a 2006 passenger vessel (inspected). The Coast Guard has recorded 23 inspections since 2012, most recently in December 2025, along with 104 deficiencies, 2 operational controls and 1 casualty investigation in 2023.
Records from 2012 to 2025. Most recent: inspection, 18 December 2025.
- Built
- 2006
- Last inspected
- 18 December 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 104 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2023
Identity
1236822
WDG2831
1160582
Flag
UNITED STATES
367519730
Maury page id
psix-1160582
Inspections, by type
…with no type recorded1
Years with a record
12 calendar years (2012–2025)
The 23 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)46.0 ft × 16.0 ft × 9.0 ft
Registered tonnagegross 44 / net 35
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNEWTON BOATS INC · SLIDELL, LA, UNITED STATES · built 2006
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portFAJARDO, PR
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 20 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it44 - Simplified, Gross Ton
35 - Simplified, Net Ton
35 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDG2831MMSI 367519730 · active · compulsorily equipped · granted 24 February 2022, expires 28 February 2032
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 23
18 December 2025
Deficiency Check · COI Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8286734
3 December 2025
COI Inspection · DAPI Audit
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8274285
4 September 2025
Examination of Repairs · Hull Examination · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8225882
5 June 2025
Drydock Extension
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8152980
5 August 2024
Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7972421
31 July 2023
Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7726227
19 May 2023
Drydock Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7691959
27 January 2023
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7629398
1 August 2022
Annual Inspection · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7519471
4 May 2021
Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7189475
21 April 2021
Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7179606
29 January 2021
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7132810
28 April 2020
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6942466
29 March 2019
Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6651885
3 December 2018
Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6590929
30 January 2018
COI Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6345953
10 October 2017
Administrative Inspection · In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6288563
31 May 2017
Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6160605
18 January 2017
Deficiency Check · Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6072500
1 June 2016
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5907438
8 August 2014
Damage Survey · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4951824
29 May 2014
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4872923
6 February 2012
Simplified Stability Test · Administrative Inspection · Initial Certification
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4245426
Deficiency record · 104
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 December 2025
Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have the following equipment at the operating station: 1. light to indicate discharge; 2. audible alarm that sounds upon discharge; 3. means to reset devices used to automatically shut down engines as required. The audible and visual alarms were found inoperable, and the control was found hanging lose and not secured to the operating stations. 46 CFR 181.420 (b).
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 December 2025
Resolved
Individual power pumps used for separate spaces are to be controlled from a central control point and must have a light or other visual means at the control point to indicate operation. All 03 bilge pump visual light at the operating stations were found inoperable. 46 CF 182.520 (a).
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 December 2025
Resolved
A portable hand bilge pump must be: 1. Capable of pumping water from all watertight compartments; 2. provided with suitable suction hose capable of reaching the bilge of each watertight compartment and discharging overboard. Portable hand bilge pump was found bend and inoperable. 46 CFR 182.520 (b).
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 December 2025
Resolved
Vapor barriers must be provided where insulation of any type is used in spaces where flammable and combustible liquids or vapors are present, such as machinery spaces. Port and stbd engine compartment fire ventilation dampers were found with gaps and not to be air/gas tight. 46 CFR 177.405 (e).
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 December 2025
Resolved
A submersible electric bilge pump may be used as a power bilge pump. The engine room submersible bilge pump was found inoperable upon testing. 46 CFR 182.520 (e).
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 December 2025
Resolved
Vapor barriers must be provided where insulation of any type is used in spaces where flammable and combustible liquids or vapors are present, such as machinery spaces. Cable penetrations into the engine room from the forward void were found not sealed and not air/gas tight. 46 CFR 177.405 (e).
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 December 2025
Resolved
Exhaust gas must not leak from the piping or any connections. Exhaust gas leak was identified in the portside engine. 46 CFR 182.430 (b).
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 3 December 2025
Resolved
Each survival craft must be secured to the vessel by a painter with a float-free link permanently attached to the vessel. Small lifefloat was found not having a painter line attached to a weaklink, and without a weaklink permanently attached to the vessel. 46 CFR 180.130 (a).
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 3 December 2025
Resolved
Each survival craft must be secured to the vessel by a painter with a float-free link permanently attached to the vessel. Large lifefloat painter line was not permanently secured to the weaklink. 46 CFR 180.130 (a).
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 3 December 2025
Resolved
Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light. Small lifefloat was found missing a painter line, water light, and both paddles were found wasted due to UV exposure.
46 CFR 180.175 (d)
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 3 December 2025
Resolved
Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light. Large lifefloat was found with an inoperable waterlight and both paddles wasted due to UV exposure. 46 CFR 180.175(d).
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 December 2025
Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 3 feet in length, but not more than 6 feet, securing the waterlight around the body of the ring life buoy. Waterlight was secured to the end of the lifeline, instead of having its own line around the lifering.
46 CFR 180.70 (d)(2)
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 December 2025
Resolved
Each ring life buoy on a vessel must:(1) Be approved in accordance with § 160.050. The lifering grabline was found wasted due to UV exposure. 46 CFR 180.70 (b)
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 December 2025
Resolved
A seat must be constructed to minimize the possibility of injury and avoid trapping occupants. Upper deck passenger benches were found missing screws in the portside and not even connected to the canopy aluminum superstructure in the starboard side. 46 CFR 177.820 (b)
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 3 December 2025
Resolved
At each initial and subsequent inspection for certification, the owner or operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including Inspection and testing of all smoke and fire detection systems, including sensors and alarms. A smoke detector is missing in the steering compartment; and conduct testing of the smoke detection system, including the detection panel located in the forward compartment. 46 CFR 176.810
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 3 December 2025
Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons who have fallen overboard. Conduct drills in presence of an attending USCG Marine Inspector.46 CFR 185.520
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 3 December 2025
Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 1 inch numbers and letters at the entranceway to that deck. Upper deck was missing marking with max allowance of passengers.46 CFR 185.602 (g)
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 3 December 2025
Resolved
An EAP training program must be conducted for the employer's crewmembers and supervisory personnel. The training program must include at least the following elements: the effects and consequences of drug and alcohol use on personal health, safety, and work environment; the manifestations and behavioral cues that may indicate drug and alcohol use and abuse; and documentation of training given to crewmembers and the employer's supervisory personnel. Supervisory personnel must receive at least 60 minutes of training. Provide evidence of training; and provide the EAP Placard. 46 CFR 16.401
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 3 December 2025
Resolved
All-round light means a light showing an unbroken light over an arc of the horizon of 360 degrees. All around light was found inoperable, and missing dayshapes. 33 CFR 83.21 (e)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 December 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to: (a)provide services necessary for safety under normal and emergency conditions;(b)Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock;(c)Minimize accidental personnel contact with energized parts; and (d)Prevent electrical ignition of flammable vapors. The following were found not in compliance:
1. Ground wire not connected in the 2nd void.
2. 02 electrical junction boxes without cover in 2nd void.
3. 02 ground wires not connected under the operating station
4. dead-end wires found under the operating station.
46 CFR 183.200
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 December 2025
Resolved
An adult life jacket must be provided for each person carried on board a vessel. Vessel was missing 01 adult-sized life jacket. Vessel is restricted to not more than 51 persons until a lifejacket is provided.46 CFR 180.71 705 restricted to 51 persons.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 December 2025
Resolved
An inspection for renewal of a Certificate of Inspection is conducted to determine if the vessel is in satisfactory condition, fit for the service intended, and complies with all applicable regulations. It normally includes inspection and testing of the structure, machinery, equipment, and on a sailing vessel, rigging and sails. The owner or operator must conduct all tests as required by the OCMI, and make the vessel available for all specific inspections and drills required by subpart H of this part. In addition, the OCMI may require the vessel to get underway. Vessel failed to pass and finish a Certificate of Inspection exam. Vessel Owner/Operator shall request a new Certificate of Inspection exam once all 21 deficiencies have been corrected, and notify the OCMI that vessel all systems have been tested and found satisfactory prior requesting thee exam.46 CFR 176.404
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 4 September 2025
Resolved
FRP delamination was found in the stbdside hull next to the keel midship. Code 705 Prior dry dock credit, 16C.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 4 September 2025
Resolved
Hatches for the collision bulkhead and steering compartment were found leaking water inside the compartment. Service these hatches to make them watertight upon testing by USCG Marine Inspector. Code 705 Prior dry dock credit, 16C.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 4 September 2025
Resolved
Two structural deck support frames connecting with the transom panel were found fractured and delaminated. Properly repair and secure with strong bond.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 4 September 2025
Resolved
A smoke detector was found hanging lose in the steering compartment. Secure and retest the smoke detector. Code 705 Prior dry dock credit, 16C.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 August 2024
Resolved
The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located. Shutoff valve was inoperable. Repair.
46 CFR 182.455(b)(4)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 August 2024
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. Engine bilge alarm light is not operational. Repair.
46 CFR 182.530(a)
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 5 August 2024
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Vessel's life float is worn. Replace life float.
46 CFR 176.808(b)
705c - 4months
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 31 July 2023
Resolved
46 CFR 181.420(a)(e)A pre-engineered fixed gas fire extinguishing system must:Automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space.
The Pre-engineered system was found inoperable when tested. Complete repairs and test to the satisfaction of the attending inspector.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 31 July 2023
Resolved
46 CFR 185.728 (b) The EPIRB's battery is replaced after it is used, or before the date required by FCC regulations in 47 CFR part 80, whichever comes sooner. Marine inspector witnessed the battery was expired. Vessel is restricted to operations within 3NM of shore until service is complete to the satisfaction of the marine inspector.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 31 July 2023
Resolved
46 CFR 185.740 (b) Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. Marine inspector witnessed the hydro static release was expired. Vessel is restricted to operations within 3NM of shore until replacement is completed to the satisfaction of the marine inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 31 July 2023
Resolved
46 CFR 182.100 All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Marine inspector witnessed temporary repairs on the starboard engine exhaust pipe. Repair or replace to original to the satisfaction of the attending marine inspector.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 31 July 2023
Resolved
46 CFR 184.420 (a)(1) As appropriate for the intended voyage, a vessel must carry adequate and up-to-date Charts of large enough scale to make safe navigation possible. Vessel did not have paper or electronic charts on board. Provide vessel with charts to the satisfaction of the attending marine inspector.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 31 July 2023
Resolved
46 CFR 181.610 A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Ammonia Capsule were not on board. Replenish fist aid kit with missing contents to the satisfaction of the attending marine inspector.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 31 July 2023
Resolved
46 CFR 181.610 A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (21/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. Only two fire buckets were on board the vessel at the time of the inspection. Provide a third fire bucket to be kept on board to the satisfaction of the attending marine inspector.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 19 May 2023
Resolved
Resecure/renew fire insulation in overhead of engine compartment at aft centerline and stbd fwd above stbd fuel tank. 7 Days provided to correct deficiency to allow vessel to splash. Extended to 30 days to correct.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 May 2023
Resolved
Renew port engine crankcase ventilation system filter housing lid. Current lid is cracked and disintegrating.
10 - Safety of Navigation › N/A - No Subsystem › Bridge operation
Issued 19 May 2023
Resolved
Renew deteriorated red control cable run for aft control steering station. 30 days provided to rectify deficiency.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 1 August 2022
Resolved
Spaces containing diesel machinery must have provision for closing all supply duct cowls or scoops that are protected by a fixed gas extinguishing system. The engine compartment starboard ventilation damper did not properly close.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 1 August 2022
Resolved
Each item of survival craft equipment must be of good quality and efficient for the purpose it is intended to serve. The starboard side life float light did not illuminate.
05 - Radio Communications › N/A - No Subsystem › Maintenance/duplication of equipment
Issued 1 August 2022
Resolved
A vessel must comply with the applicable requirements for any radio installations and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Vessel's Safety Radiotelephony Certificate was expired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 1 August 2022
Resolved
Gauges to indicate engine revolutions per minute, jacket water discharge temperature, and lubricating oil pressure must be provided for all propulsion engines installed in the vessel. Starboard engine tachometer and analog battery voltage meter provided inaccurate readings.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 1 August 2022
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in normally unmanned spaces. The steering compartment bilge alarm light is inoperable.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 August 2022
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards. Dead end wires under the operating station and on the starboard side of the void forward of the engine compartment require removal.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 August 2022
Resolved
For each marine casualty required to be reported by 185.202, the owner, agent, master, or person in charge of the vessel shall determine whether there is any evidence of alcohol or drug use by individuals directly involved in the casualty. The vessel's alcohol test swabs were expired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 May 2021
Resolved
Propulsion machinery must be suitable in type and design. Found the following:
a. the U-bolts of the forward bridge throttle controls is wasted;
b. the aft throttle control station the U-Bolts for the cables wasted away and was repaired by a non-approved method. 46 CFR 182.200(a).
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 May 2021
Resolved
Gauges to indicate RPM must be provided for all propulsion engines installed in a vessel. The portside bridge RPM gauge reads 600 RPMs with the engine stopped. 46 CFR 182.410 (b).
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 May 2021
Resolved
The discharge ends of fuel tank vents must terminate on the hull exterior, as high above the water as practicable. Found both port & starboard fuel tank vents terminates inside the engine room. Unable to determine if the vent lines are fitted with flame screens in accordance with 46 CFR 182.450 (c). 46 CFR 182.450 (d) (e).
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 May 2021
Resolved
Provisions must be made for closing all supply ducts for a space protected by a fixed gas extinguishing system. Both port & starboard engine room supply ducts do not completely close when the covers are activated. 46CFR182.465(b).
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 6 May 2021
Resolved
A hatch exposed to the weather must be watertight. Found the following hatches not being watertight:
a. bow deck hatch is leaking excessively;
b. steering compartment hatch was found leaking excessively and not attached to the hatch frame by a captive chain or other device;
c. compartment forward of the engine room was found the hatch to be missing the rubber gasket seal and the securing devices are wasted and non-operational and not attached to a captive chain or other device.
46CFR179.360
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 May 2021
Resolved
All observed unsafe practices and other hazardous situations must be corrected. Series of holes were found at the height of the rub rail, portside at the forward void (anchor chain locker). Properly seal holes or install proper correct bolts. 46 CFR 176.830 (a)
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 May 2021
Resolved
The lights prescribed by these rules shall, if carried, also be exhibited from sunrise to sunset in restricted visibility. The following navigation lights must be:
a. starboard side was found UV damaged and needs to be replaced;
b. stern light must be mounted as far aft as possible and visible in accordance with the regulation;
c. Anchor light was found with UV light damage and needs to be replaced.
33 CFR 83.20
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 May 2021
Resolved
Vessel is required to have on board a portable hand bilge pump in accordance with 46CFR 182.520 (a). Vessel portable bilge hand pump was found to be broken and not working. Provide a working portable bilge hand pump. 46CFR182.520(a).
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 6 May 2021
Resolved
Each window and its means of attachment to the hull or deck house, must be capable of withstanding the maximum load from wave and wind conditions. Main deck center window frame was found broken, with glass being supported by a screwdriver. Properly conduct repairs on center window. 46CFR177.1020.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 6 May 2021
Resolved
Vessels certificated to operate on a limited coastwise route must have on board a FCC type 1 406Mhz EPIRB installed in a float-free position. The EPIRB hydrostatic release was found to be expired. Replace with a valid hydrostatic release. 46CFR 180.205 (3).
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 May 2021
Resolved
Each portable fire equipment (extinguishers) on a vessel must be of an approved type. The operating station fire extinguisher was found to have a broken support or bracket. Provide an approved bracket or support according with the fire extinguisher label.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 May 2021
Resolved
An emergency instructions placard must be tailored to the vessel operations and existing emergency equipment. Vessel has posted the recommended emergency instructions format and must be updated. 46 CFR 185.512.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 May 2021
Resolved
Each lifeline on a ring life buoy must be of a dark color if synthetic, or of a type certified to be resistant to UV deterioration. The lifeline was found to be light in color and not be UV resistant. 46 CFR 180.70 (c) (b).
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 6 May 2021
Resolved
A vessel must comply with the applicable procedures and record requirements of 33CFR151.57. Vessel was found not having a waste management plan on board. 46 CFR184.702/ 33CFR151.57.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 May 2021
Resolved
On a vessel on which the number of passengers permitted in the upper deck is limited by stability criteria, as indicated by stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 1” numbers, at the entranceway to that deck. Provide allowed number of passengers permitted in the upper deck in accordance with current stability letters. 46CFR185.602(g).
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 May 2021
Resolved
All cable and wire must be installed with metal supports spaced not more than 24” apart, and in such a manner as to avoid chafing and other damage, and as high above the bilges. The following cables and wiring needs to be supported:
a. portside flood light electric cable needs to be secured; b. Electric boat cable connected to the starboard side battery was found hanging and making contact with the hull; c. secure or remove dead-end wires found underneath the operating station controls.
46CFR183.340 (b)(4)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 April 2020
Resolved
FWD bilge pump was not UL listed
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 28 April 2020
Resolved
Life floats were not marked with vessel name.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 28 April 2020
Resolved
Life floats were not fitted with paddles.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 28 April 2020
Resolved
Paddles were not marked with vessel name.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 28 April 2020
Resolved
Life floats were not separated by spacers.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 April 2020
Resolved
Waterlight was not lashed around ring life buoy with corrosion resistant clip.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 28 April 2020
Resolved
First-aid kit did not have all required contents.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 April 2020
Resolved
Child life jacket stowage was not properly marked.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 28 April 2020
Resolved
MOB and Fire drills were not logged.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 28 April 2020
Resolved
EPIRB tests were not being logged monthly.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 28 April 2020
Resolved
Vessels all-round white anchor light was inoperable.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 April 2020
Resolved
Portable lights had inoperable batteries.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 1 April 2019
Resolved
The EPRIB on board had a battery expiration date of 2017 and the antenna was damaged. Vessel may not operate past (03) nm until EPRIB is replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 April 2019
Resolved
The COI and Stability Letter were not posted on the vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 April 2019
Resolved
Vessel must replace all plastic zip ties in the engine room with proper metal supports.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 1 April 2019
Resolved
Each life float must be fitted with two paddles. The vessel’s life floats do not have paddles.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 1 April 2019
Resolved
The vessel’s MMSI number was not entered into the radio.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 5 February 2018
Resolved
08 lifejackets were found in poor condition. Limited to carrying no more than 44 persons on board.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 5 February 2018
Resolved
Replace retroreflective tape on all life jackets
Electrical › Electrical Distribution System (service) › Cable
Issued 5 February 2018
Resolved
Install metal supports on cables under operating station.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 5 February 2018
Resolved
Secure CPUs in engine compartment
Communications › Alarms/Indicators › Bilge Alarm
Issued 31 May 2017
Resolved
Prove Proper Operation of Bildge High Water alarm System. 46CFR182.530 Prior to carrying passengers.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 31 May 2017
Resolved
Provide complete first aid kit
Lifesaving › Inflatable Liferafts › Not on Board
Issued 31 May 2017
Resolved
Prove proper installation of inflatable life raft.
Engineering › Fuel Oil Service System › Valve, Control
Issued 18 January 2017
Resolved
Replace the corroded fuel shut off cable on the port side.
Engineering › Diesel Engine (propulsion-direct drive) › Gear/Clutch Starter (electric)
Issued 18 January 2017
Resolved
Replace the corroded/broken wire on the port engine alternator.
Construction/Loadline › Hull › Bracket
Issued 18 January 2017
Resolved
Repair two cracked welds on the life raft release track and 4 welds on the canopy.
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 18 January 2017
Resolved
Fix broken grounding cable on the port side of the engine room.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 January 2017
Resolved
Replace 16 gauge wires with the proper wiring for power and lightning.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 18 January 2017
Resolved
Properly support the Port and STBD PC units in the Engine Room.
Construction/Loadline › Structures › Deck Plating
Issued 18 January 2017
Resolved
Make all strut bolts watertight
Construction/Loadline › Hull › Bracket
Issued 18 January 2017
Resolved
Properly secure all SCUBA bottle racks on the Port and STBD side.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 January 2017
Resolved
Remove all deadended wires on the backside of breakers.
Engineering › Bilge Water Management System › Interface Detector
Issued 1 June 2016
Resolved
Prove proper operation of engine room and lazarette bilge high level alarm. Conduct Rounds every 30 minutes and/or prior to each departure.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 1 June 2016
Resolved
Provide working waterlight. Vessel restricted to daytime operations and clear visibility.
Communications › Radio Communications › VHF Radiotelephone
Issued 1 June 2016
Resolved
Program MMSI Number in VHF-DSC Radio.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 1 June 2016
Resolved
Relocate stern light to aft most rail ensuring clear visibility to vessel traffic.
Engineering › Fuel Oil Service System › Filter
Issued 8 August 2014
Resolved
Provide a written report attesting to the damage and repairs conducting on the Port MDE.
Engineering › Fuel Oil Service System › Filter
Issued 8 August 2014
Resolved
Conduct a sea trail in the presence of CG Marine Inspectors prior to carrying passengers.
Communications › Alarms/Indicators › Bilge Alarm
Issued 29 May 2014
Resolved
Prove proper operation of forward void bilge alarm.
Communications › Alarms/Indicators › Bilge Alarm
Issued 29 May 2014
Resolved
Provide visual indicator light at the operation station to indicate when any automatic bilge pump is operating.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 29 May 2014
Resolved
Monitor bilge level at forward void every hour and log while operating .
Casualty record · 1
27 January 2023Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 7629398
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.