A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 21
17 March 2026
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8332473
18 March 2025
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8095996
4 October 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8015311
5 March 2024
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7874784
22 May 2023
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7693839
14 March 2023
Deficiency Check · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7650983
8 February 2022
Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7392585
30 November 2021
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7359642
23 November 2021
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7357120
9 March 2021
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7154941
31 March 2020
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6933610
10 March 2020
Annual Inspection · DAPI Audit · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6921340
4 September 2019
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6804004
12 March 2019
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6658291
27 November 2018
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6606428
7 August 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6503614
13 March 2018
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6386522
16 March 2017
DAPI Audit · Internal Structural Exam · COI Inspection · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6105821
9 May 2016
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5941528
20 November 2015
Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5768207
21 May 2012
Deficiency Check · DAPI Audit · In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4317375
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 5 March 2024
Resolved
Each scuttle used as means of escape must be capable of being opened by one person, from either side, in both light and dark conditions. The method of opening the means of escape must be obvious, rapid, and of adequate strength.
The emergency escape scuttle from the galley into the dining room / main deck area has a carpet overlay that sits flush with the surrounding carpet which makes it difficult to open from the main deck. Provide a pull tab or similar arrangement that allows for rapid removal of the escape scuttle by a single person from the main deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2024
Resolved 12 March 2024
Resolution: Handles were added to the hatch. All sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 5 March 2024
Resolved
A hatch cover must be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantiative strength to prevent its loss.
The hatch for entry into the forepeak is missing its captive chain/securing device.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2024
Resolved 12 March 2024
Resolution: A chain was added to the hatch connecting it to the hull. Sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 March 2023
Resolved
A vessel must carry one floating waterlight as part of its ring lifebuoys. The light be must be a floating waterlight approved under 161.010.
Battery for waterlight attached to aft ring life buoy and for two port side life floats are expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2023
Resolved 27 March 2023
Resolution: Received email from vessel rep with pictures showing two waterlight batteries had been replaced and a third waterlight had been replaced in its entirety.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 14 March 2023
Resolved
Each ladder used as a means of escape must be mounted at least 7 inches from the nearest permanent object in back off the ladder. Rungs must be at least 16 inches in width and no more than 12 inches apart. Footholds, handholds, ladders, and similar means provided to aid escape must be suitable for use in emergency conditions and of rigid construction.
The emergency means of escape for the engine room requires stepping up onto a raised platform several feet off the deck in order to access the ladder, or stepping on a PVC pipe in order to step up onto the raised platform.
Update 3/27/23: extended deficiency due date to 6/14/23.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2023
Resolved 22 May 2023
Resolution: Received email from vessel rep with pictures showing an additional rung installed on the emergency escape ladder. Accepted as objective evidence to clear the deficiency.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 15 March 2022
Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 2 inches high: “EMERGENCY EXIT, KEEP CLEAR”.
Emergency escape scuttles for galley space and engine room are not marked on top of scuttle where the exit into the dining room space.
*On 3/18/22, this deficiency was extended to 4/15/22 and 'prior to carry passengers' requirement removed, based on temporary signage arrangements.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 March 2022
Resolved 14 April 2022
Resolution: Vessel operator provided pictures of new permanent signage in dining room that marks the emergency escape hatches.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 15 March 2022
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent.
Current arrangement for engine room ventilation covers/closures requires a crewmember to climb along the exterior side of the vessel, flip up the ventilation covers, and secure them with a screwdriver and screw.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2022
Resolved 4 May 2022
Resolution: Operator provided pictures of newly installed remote pull cable system that permits closure of the engine room ventilation flaps from the upper deck.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 March 2022
Resolved
All cable and wire must be installed with metals supports spaced not more than 24 inches apart…the use of plastic tie wraps must be limited to bundling or retention of multiple cable installations, and not used as a means of support.
Several wiring runs found not properly supported, to include transducer wiring in tank compartment and camera wiring in galley space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2022
Resolved 14 April 2022
Resolution: Vessel operator provided pictures of wiring properly supported by metal supports / within cable raceways.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 15 March 2022
Resolved
Electrical equipment and installations must be suitable for the roll, pitch, and vibration of the vessel underway. All unfired pressure vessels must be installed to the satisfaction of the cognizant [name withheld] style portable air compressor that supplies compressed air for ship’s horn found plugged in to outlet in tank compartment and sitting on deck unsecured.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2022
Resolved 14 April 2022
Resolution: Vessel operated provided pictures of compressor permanently secured to the deck and hard-wired.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 March 2022
Resolved
Placards containing instructions for the donning and use of life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers.
Life jacket donning placards posted at port side of wheelhouse and on port life jacket storage box are for the [name withheld] type of life jackets, rather than the Taylortek type of life jackets maintained onboard. Post correct donning placards.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2022
Resolved 14 April 2022
Resolution: Vessel operator provided pictures of life jacket donning placards appropriate for type of life jackets provided onboard, posted in appropriate areas on the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 March 2020
Resolved
At each initial and subsequent inspection for certification, the steering systems shall be in suitable condition and fit for the service intended.
Deficiency: During inspection, the steering hydraulic gauge located in aft steering was inoperable/broken.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2020
Resolved 31 March 2020
Resolution: Vessel conducted tests as specified by the manufacturer (JASTRAM), all sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 March 2020
Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate the recovery of persons who have fallen overboard.
Deficiency: During MOB drill, the deckhand failed to have a safety line attached to himself prior to recovering the person in the water. Provide evidence to meet the required standards for safety/tending line as specified in vessel's Emergency Instructions for Man Overboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2020
Resolved 24 March 2020
Resolution: provided photo evidence for the safety line during MOB (as indicated in vessel's Emergency Instruction), all sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 March 2020
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery
failure, and personnel injury.
Deficiency: Upon inspection, a steady leak in the fire pump piping was observed.
Action required: 10 - Deficiency Rectified
Due 10 March 2020
Resolved 10 March 2020
Resolution: Corrected on the spot and was observed by a Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 March 2020
Resolved
A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight.
Deficiency: The gasket for the fuel line (located at the starboard bulkhead of the galley) was loose and was not providing watertight integrity for the bulkhead.
Action required: 10 - Deficiency Rectified
Due 10 March 2020
Resolved 10 March 2020
Resolution: Corrected on the spot and was observed by a Marine Inspector.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 7 August 2018
Resolved
Vsl is broadcasting: No static draft information and no dimension information (AIS Antenna Position ABCD values equals 0).
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 September 2018
Resolved 17 October 2018
Resolution: Vessel met all requirements for AIS broadcasting.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 20 November 2015
Resolved
Stbd lifefloats painter lines to bridle are wasted, replace.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 November 2015
Resolved 10 December 2015
Resolution: Received email Pics showing the above deficiency corrected.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 20 November 2015
Resolved
Lifejacket lockers do not have amount of lifejackets stenciled on outside of locker.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 November 2015
Resolved 10 December 2015
Resolution: Received email Pics showing the above deficiency corrected.
Engineering › Steering Gear System › Pump
Issued 20 November 2015
Resolved
Steering pump leaking, repair and prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 November 2015
Resolved 10 December 2015
Resolution: Received email Pics showing the above deficiency corrected.
Engineering › Steering Gear System › Power Unit
Issued 20 November 2015
Resolved
Electrical connection on steering pump is not properly installed. Repair/renew.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 November 2015
Resolved 10 December 2015
Resolution: Received email Pics showing the above deficiency corrected.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 20 November 2015
Resolved
Area adjacent to the bar needs to have carpet removed and tile or noncombustable flooring installed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 April 2016
Resolved 25 November 2015
Resolution: Cleared above deficiency, "T" boats not required to meet SFP.
Lifesaving › Lifefloat › Markings
Issued 21 May 2012
Resolved
Label number of passengers, and provide spaces between all lifefloats. Secure/lash paddles to lifefloats.
Due 4 June 2012
Resolved 31 May 2012
Resolution: Lifefloats properly labeled, spaced with plastic spacers and paddles secured.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 21 May 2012
Resolved
Provide means of safely closing ventilation, and demonstrate to attending marine inspector.
Due 4 June 2012
Resolved 31 May 2012
Resolution: Means provided and demonstrated by crew.
Stability › Watertight Integrity › General
Issued 21 May 2012
Resolved
Adjust closing device on watertight door to engine compartment. Demonstrate to Marine Inspector.
Condition: Improper/Lack of Maintenance
Due 4 June 2012
Resolved 31 May 2012
Resolution: Door adjusted to the satisfaction on the MI.
Engineering › Steering Gear System › Hydraulic Hose
Issued 21 May 2012
Resolved
Steering hose starboard side needs chafing gear installed.
Due 4 June 2012
Resolved 31 May 2012
Resolution: Chafing gear installed to the satisfaction of the MI.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 21 May 2012
Resolved
Update master's radio permit from restricted to marine radio operators permit.
Condition: Invalid
Due 29 June 2012
Resolved 31 May 2012
Resolution: Captain who will operate the vessel provided permit to MI.