MAURY USCG vessel records
← All vessels

BBC ONYX

BBC ONYX is a 2008 freight ship. The Coast Guard has recorded 11 inspections since 2016, most recently in May 2024, along with 7 deficiencies and 2 operational controls.

Records from 2016 to 2024. Most recent: inspection, 18 May 2024.

Built
2008
Last inspected
18 May 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 18 May 2024
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9506746
1160891
Flag
ANTIGUA AND BARBUDA
Maury page id
psix-1160891

Documentation record

Tonnage as PSIX records it12810 - Convention (Subpart B), Gross Ton
5938 - Convention (Subpart B), Net Ton
14359 - Dead Weight, Metric Ton
23004 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 11

18 May 2024 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7914515
18 August 2023 Explosive Handling Operation-Commercial
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7771210
15 August 2023 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7768711
31 July 2023 PSC B
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7746049
19 August 2021 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7291863
30 May 2021 PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7202914
1 January 2020 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6881131
22 September 2019 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6817814
6 January 2019 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6881136
4 November 2017 PII Safety Exam · ISPS II Exam · COE-Offshore
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6300659
16 September 2016 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5990998

Deficiency record · 7

04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 18 May 2024 Resolved
Where the emergency source of electrical power is a generator, it shall be started automatically upon failure of man source of electrical power supply. the E-Gen was found in manual mode and has been in position since last test date 27Apr2024. 74Solas(04) 11-1/43.3.1.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2024
Resolution: E-Gen was position was set to automatic.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 18 May 2024 Resolved
Firefighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO identified fixed CO2 nozzle beside L.O tank in the engine room covered in tape. Tape was removed on the spot. 74SOLAS(20) II-2/4.2.1.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2024
Resolution: Tape removed from CO2 nozzle.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 May 2024 Resolved
The purpose of this regulation is to prevent the ignition of combustible materials of flammable liquids; The ignitability of combustible materials shall be restricted. PSCO observed 20-30 cardboard pieces stored on E.R. deck besides active diesel oil leak. Additionally, PSCO observed several oil soaked rags stuffed throughout E.R. and purifier flat. 74SOLAS (20) II-2/4.1.3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2024
Resolution: Cardboard pieces and rags removed.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 18 May 2024 Resolved
A ship in which F/O is used, the arrangement for storage, distribution, and utilization of the fuel oil shall ensure the safety of ship and persons onboard. PSCO observed active diesel oil leak on bunker supply line valve in E.R. Leak was contained in a ZOL bucket which was actively overflowing in bilge. 74SOLAS(20) II-2/4.2.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2024
Resolved 3 June 2024
Resolution: Received class report attesting to replacement of the FTV41 valve on the fuel oil transfer and bunkering system. Pressure test carried out by crew on 21MAY24 with satisfactory result. During class attendance, no oil leaks were observed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 May 2024 Resolved
Hydraulic operated steering gear shall be provided with the following arrangements to maintain the cleanliness of fluid taking into account the type and design of system. PSCO found leaks around hydraulic tank and pooled fluid on deck. Crew had removed fill pipe cape and modified piping arrangements resulting in spilled fluid on deck. 74SOLAS(04) II-1/29.12.1
Action required: 10 - Deficiency Rectified
Resolved 3 June 2024
Resolution: Crew reinstalled cap and cleaned fluid from deck.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 31 July 2023 Resolved
74 SOLAS (04) II-1/44.2 EACH EMERGENCY GENERATING SET ARRANGED TO BE AUTOMATICALLY STARTED SHALL BE EQUIPPED WITH STARTING DEVICES APPROVED BY THE ADMINISTRATION WITH A STORED ENERGY CAPACITY OF AT LEAST THREE CONSECUTIVE STARTS. A SECOND SOURCE OF ENERGY SHALL BE PROVIDED FOR AN ADDITIONAL THREE STARTS WITHIN 30 MIN UNLESS MANUAL STARTING CAN BE DEMONSTRATED TO BE EFFECTIVE. PSCO OBSERVED THE SECOND SOURCE OF POWER, FOR THE SHIP'S EMERGENCY GENERATOR, TO BE INOPERABLE.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 July 2023
Resolved 2 August 2023
Resolution: Vessel replaced all batteries used to start EDG and was able to satisfactorily start the EDG with two different sources of power.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 4 November 2017 Resolved
Fire fighting appliances shall be properly tested and inspected. 05 dry chem and 02 CO2 portable extinguishers were examined and found deterioratedand unserviceable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 November 2017
Resolution: Recieved class report, dificiency corrected.

Ownership record