This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
The counts in the strip above are the same counts; this table splits the inspections by
the kind of activity recorded. A blank resolution means none was recorded in this data; it
does not establish that a deficiency is outstanding. Years with a record are calendar
years in which a record exists, not years in service.
What Maury does not do.
Documentation record
Tonnage as PSIX records it32839 - Convention (Subpart B), Gross Ton 19559 - Convention (Subpart B), Net Ton 58018 - Dead Weight, Metric Ton 68970 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 1
5 April 2017ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6118213
Code 0660. After any survey of the ship under regulations 7, 8, 9, or 10 has been completed, no change shall be made in the structural arrangements, machinery, equipment snd other items covered by the survey, without the sanction of Administration. Inspectors discovered life jackets with unapproved modifications to the front panel. 74 SOLAS (2014) I/11 (b) 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 April 2017
Resolution: All life jackets with lights have been renewed.
Fire Fighting › Structural - A Class Divisions › Stairways
Issued 5 April 2017Resolved
Code 0750. Where "A" class divisions are penetrated, such penetrations shall be tested in accoradance with Fire Test Procedures Code. Such penetrations shall be suitably insulated by extension of the insulation at the same level of the division. Inspectors discovered Internet cable penetrating the "A" class stairwell doors on multiple decks. 74 SOLAS(14) II-2/9.3.1 40ac.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 8 April 2017
Resolution: Internet cable from stairway doors have been removed, and holes have been filled with approved fire mastic.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.