TRABZON is a 2011 freight ship. The Coast Guard has recorded 12 inspections since 2017, most recently in July 2025, along with 7 deficiencies — 1 with no resolution recorded — and 3 operational controls.
Records from 2017 to 2025. Most recent: operational control imposed, 29 July 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it44635 - Convention (Subpart B), Gross Ton 26712 - Convention (Subpart B), Net Ton 95327 - Displacement, Metric Ton 82000 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 12
29 July 2025Deficiency Check · PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8188711
18 July 2025Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8188839
8 July 2025Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8179553
11 February 2025Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8077970
8 September 2023PSC B
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7782872
6 September 2022Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7552295
10 August 2021Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7274971
6 August 2021Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7279139
23 April 2021PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7178101
17 August 2019Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6774615
28 December 2017Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6329729
17 January 2017ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6067634
10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 29 July 2025Resolved
The Administration shall be satisfied that adequate arrangements are in place to ensure that the performance of the equipment required by this chapter is maintained. PSCOs observed objective evidence that the vessel's VDR was inoperable due to showing an error. Captain and electrician were unaware of the location of the error source. When checking the VDR's manual, PSCOs discovered the error resulted in the VDR not communicating properly and recording the data required by IMO Res. A.861(20)
74SOLAS(20)V/16.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 31 July 2025
Resolution: Tech services (Marine BCTEC) attended vessel 30JUL25 and replaced necessary hardware in VDR system and conducted functional tests. PSCO confirmed successful operation of VDR and deenergized echo depth sounder to confirm VDR interaction with equipment.
Whenever a defect is discovered, either of which affects the safety of the ship or the efficiency or completeness of its life saving appliances or other equipment, the master or owner of the ship shall report at the earliest opportunity to the Administration or Recognized Organization, and to the appropriate authorities of port state control. Vessel failed to report VDR issue to flag and USCG.
74SOLAS(20)I/11(c)
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 July 2025
Resolution: PSCO reviewed documentation including correspondence with company/RO and LR class survey indicating proper notifcation of inoperable VDR and EDG Sequence Test Switch. Deficiency code changed from 17ac to 10c.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 29 July 2025No resolution recorded
Ships shall be designed, constructed, and maintained in compliance with the structural, mechanical, and electrical requirements of a classification society which is recognized by the Administration. PSCO observed sequential test switch on the emergency switchboard to be inoperable.
74SOLAS(20)II-1/3-1
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 12 August 2025 — due date passed with no resolution recorded
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 23 April 2021Resolved
Fire fighting systems shall be maintained ready for use. Ships crew took over one hour to operate emergency fire pump.
74SOLAS(14)II-2/14.1.1
Action required: 10 - Deficiency Rectified
Due 23 April 2021
Resolved 23 April 2021
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 23 April 2021Resolved
Doors required to be self-closing shall not be fitted with hold back hooks. PSCO observed 02 self closing doors leading to galley held open with hold back hooks.
74SOLAS(14)II-2/9.4.2.2
Action required: 10 - Deficiency Rectified
Due 23 April 2021
Resolved 23 April 2021
07 - Fire Safety › N/A - No Subsystem › Jacketed high pressure lines and oil leakage alarm
Issued 23 April 2021Resolved
Arrangements for lube oil lines shall be such as to ensure safety of ship. Double jacket piping on lube oil supply lines to #1, #2, #5 and #6 cylinders are showing excessive signs of wastage.
74SOLAS(14)II-2/4.2.3
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 August 2021
Resolution: Replaced #1, #2, #5, And #6 L/O lines.
Documentation › Logs/Records › Ballast Water Reporting Form
Issued 17 January 2017Resolved
PSCO observed that vessel's Master did not submit ballast water report prior to entering the New Orleans COTP Zone. 33CFR151.2041 10c
Action required: 705 - Other - as specified
Due 17 January 2017
Resolved 17 January 2017
Resolution: Master was educated on how to submit report and provided evidence of submission prior to the completion of the PSC Exam.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.