Records from 2016 to 2026. Most recent: inspection, 24 March 2026.
Inspection history · 38
24 March 2026
Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8331269
3 February 2025
Annual Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8074633
7 June 2024
Annual Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7931824
23 March 2023
Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7655424
26 January 2023
Annual Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7628905
21 June 2022
Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7482807
22 November 2021
Annual Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7408838
17 March 2021
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7158038
8 December 2020
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7108268
2 December 2020
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7109207
8 October 2020
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7073974
7 February 2020
In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6905970
4 February 2020
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6902611
15 October 2019
Deficiency Check · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6824801
11 April 2019
Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 6660324
4 February 2019
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6628432
4 December 2018
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6603528
2 November 2018
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6577667
21 September 2018
In-Service Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6570141
4 September 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6531786
23 February 2018
Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6360552
18 October 2017
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6306402
3 April 2017
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6116487
29 January 2017
Deficiency Check · In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6080628
30 November 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6049840
16 November 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6042204
27 October 2016
MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 6031439
29 September 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6012585
5 August 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5963490
26 July 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5953836
12 July 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5937784
12 July 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5938311
28 June 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5922731
28 June 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5922780
21 June 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5914176
2 May 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5867502
29 April 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5865469
5 February 2016
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5811282
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 3 February 2025
Resolved
Each lifeboat, rigid life-raft, and rescue boat, unless otherwise stated in this paragraph, must carry the equipment specified for it in table 108.575(b) of this section. Observed all lifeboats on board facility to not have water in the lifeboats. Ensure water meeting this regulation, is retrieved and stored in all lifeboats accordingly.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 February 2025
Resolved 6 March 2025
Resolution: Recieved evidence of water rations being ordered, recieevd, and installed in all lifeboats.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 7 February 2020
Resolved
Oil was observed leaking from the oil filter housing while engine was running. Repair oil leak on firepump and provide tech report. All repairs and tech report to be submitted to the USCG for approval prior to using.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 February 2020
Resolved 4 March 2020
Resolution: Received email from OIM with evidence of clearance.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 7 February 2020
Resolved
Fuel hose on firepump B was observed to be cracked and severely deteriorated. Fuel hose I.W.O. of the racor filter assembly to be replaced and pictures sent to the USCG.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 February 2020
Resolved 4 March 2020
Resolution: Received email from OIM with evidence of clearance.
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 15 October 2019
Resolved
During time of inspection there was no credentialed BCO aboard. COI requires at least (1) one on board at all times. Provide BCO endorsement within 3 months.
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 January 2020
Resolved 2 January 2020
Resolution: Recevied e-mailed documentation confirming the endorsement credentials of the onboard BCO at the time of the inspection.
Lifesaving › Inflatable Liferafts › Float Free
Issued 23 February 2018
Resolved
Spar is required to have liferafts arranged for float free launching and have an aggregate capacity that will accommodate the total number of persons permitted on board. Of the liferafts on board, only (2) twenty-five man liferafts are currently in a float free arrangement. Provide a plan to D8 OCMI to ensure float free arrangement for liferafts to ensure the total number of persons on board to the satisfaction of USCG marine inspector.
Action required: 705 - Other - as specified
Due 23 March 2018
Resolved 4 December 2018
Resolution: Visually inspected that liferafts were moved to a float free condition.
Lifesaving › Lifeboat › Self-contained Air Support System
Issued 23 February 2018
Resolved
Lifeboat’s approved under 46CFR160.035 are required to have a supplied air system. During testing of the supplied air system on all (3) lifeboats, all bottles were below minimum pressure and regulating valves were either inoperable, or set incorrectly. Provide 3rd party servicing report attesting to proper operation of supplied air system to the satisfaction of the USCG Marine Inspector.
Action required: 705 - Other - as specified
Due 23 March 2018
Resolved 23 March 2018
Resolution: Documentation from OIM clearance of issue.
Electrical › Electric Supply System (service) › Cable
Issued 29 January 2017
Resolved
Cable to ESS system was found to be lose and caused a facility blackout. Operational control issued.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 February 2017
Resolved 3 February 2017
Resolution: Facility engineers trouble shot cause and determined lose wire was at fault. Initiated multiple corrective actions to the satisfaction of USCG and BSEE.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 29 January 2017
Resolved
Multiple panelboards were found to have incorrect or outdated circuit directories.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 March 2017
Resolved 12 March 2017
Resolution: OIM sent email stating all panelboard directories have been labeled.
Documentation › Safety Management System › Reports and Analysis Procedures
Issued 29 January 2017
Resolved
Facility should provide corrective actions reports stemming from facility blackout that occured on 27JAN2017.
Action required: 705 - Other - as specified
Due 31 May 2017
Resolved 21 October 2020
Resolution: Resolved due to time and no further incidents.
Construction/Loadline › Structures › Superstructure
Issued 1 November 2016
Resolved
Facility is to provide approval letter for new module
Due 1 November 2016
Resolved 1 November 2016
Resolution: Facility rep provided copy of 10-82 approval letter to attending Marine Inspector.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 1 November 2016
Resolved
Numerous fire doors were found to not meet structural fire protection. Repair all fire doors. Extended to 1Feb17-now 1Mar17 final, due to ordered parts availability. [name withheld].
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 17 March 2017
Resolution: OIM Provided email stating that all fire doors were repaired and in service.
Electrical › Electrical Distribution System (emergency) › Main-emergency Bus Tie
Issued 1 November 2016
Resolved
Facilitys Emmergency BUS had the ability to feed the Aux Bus. Provide documents for this BUS tie in for MSC review.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 1 December 2016
Resolved 1 December 2016
Resolution: Reviewed Class approval for installation.
Electrical › Electric Generation Source (emergency) › Switch
Issued 1 November 2016
Resolved
Emergency generator did not shut down on overspeed trip.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 November 2016
Resolved 1 November 2016
Resolution: Facilitys crew identified that the issue was the installation of a new ECM that was incorrectly programmed. On 2nd visit the crew properly demostrated the operation of the E-Gen overspeed.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 1 November 2016
Resolved
Facility did not have approved Fuel Oil Transfer Procedurs on board. Extended to 1Jan17. RSM.
Action required: 705 - Other - as specified
Due 1 January 2017
Resolved 13 February 2017
Resolution: Provided documentation on this date satisfied the requirement.
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 November 2016
Resolved
Mulitiple cable transits through structural fire boundries were missing.
Condition: Improper Installation
Due 1 November 2016
Resolved 1 November 2016
Resolution: Facility had 3rd party contractor fly out to correct all cable transits throughout the faciltiy.
Lifesaving › Rescue Boat › Carriage Requirement
Issued 1 November 2016
Resolved
Facility could not provide proper documentation for lifeboats as also being certificated as rescue boat under 46 CFR 160.156/54/0
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 November 2016
Resolved 2 November 2016
Resolution: Company rep provided documentation attesting the the dual certification of the lifeboats installed on the facility.
Fire Fighting › Structural - A Class Divisions › Door Frames
Issued 5 February 2016
Resolved
Pantry door hinge is sprung and fire door leaves gap when closed. Repair or replace fire door.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 6 March 2016
Resolved 8 February 2016
Resolution: Door frame replaced and door rehung. Received email verification of rectification with picture of repairs and video of door closing correctly (attached). Clear deficiency.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 5 February 2016
Resolved
Estimated quantities of food waste discharged to the sea were not recorded in logs of food waste discharges to the sea. Include food waste discharge quantities in logged discharge entries.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 February 2016
Resolved 5 February 2016
Resolution: GS1 started recording food waste discharge to sea quantities prior to departure of inspectors, and submitted final food waste log format to inspectors by email. (attached)