← All vessels
GULFSTAR 1
GULFSTAR 1 is a 2014 industrial vessel. The Coast Guard has recorded 40 inspections since 2014, most recently in March 2026, along with 18 deficiencies and 2 operational controls.
Records from 2014 to 2026. Most recent: inspection, 24 March 2026.
- Built
- 2014
- Last inspected
- 24 March 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 18 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
WQQX540
1161554
Flag
UNITED STATES
—
Maury page id
psix-1161554
Inspections, by type
…with no type recorded3
Years with a record
13 calendar years (2014–2026)
The 40 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.
Documentation record
Tonnage as PSIX records itNot recorded
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 40
24 March 2026
Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8331269
3 February 2025
Annual Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8074633
7 June 2024
Annual Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7931824
23 March 2023
Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7655424
26 January 2023
Annual Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7628905
21 June 2022
Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7482807
22 November 2021
Annual Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7408838
17 March 2021
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7158038
8 December 2020
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7108268
2 December 2020
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7109207
8 October 2020
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7073974
7 February 2020
In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6905970
4 February 2020
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6902611
15 October 2019
Deficiency Check · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6824801
11 April 2019
Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 6660324
4 February 2019
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6628432
4 December 2018
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6603528
2 November 2018
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6577667
21 September 2018
In-Service Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6570141
4 September 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6531786
23 February 2018
Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6360552
18 October 2017
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6306402
3 April 2017
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6116487
29 January 2017
Deficiency Check · In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6080628
30 November 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6049840
16 November 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6042204
27 October 2016
MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 6031439
29 September 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6012585
5 August 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5963490
26 July 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5953836
12 July 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5937784
12 July 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5938311
28 June 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5922731
28 June 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5922780
21 June 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5914176
2 May 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5867502
29 April 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5865469
5 February 2016
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5811282
14 December 2015
Administrative Inspection · Construction Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5782294
24 March 2014
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4822228
Deficiency record · 18
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 3 February 2025
Resolved
Each lifeboat, rigid life-raft, and rescue boat, unless otherwise stated in this paragraph, must carry the equipment specified for it in table 108.575(b) of this section. Observed all lifeboats on board facility to not have water in the lifeboats. Ensure water meeting this regulation, is retrieved and stored in all lifeboats accordingly.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 7 February 2020
Resolved
Oil was observed leaking from the oil filter housing while engine was running. Repair oil leak on firepump and provide tech report. All repairs and tech report to be submitted to the USCG for approval prior to using.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 7 February 2020
Resolved
Fuel hose on firepump B was observed to be cracked and severely deteriorated. Fuel hose I.W.O. of the racor filter assembly to be replaced and pictures sent to the USCG.
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 15 October 2019
Resolved
During time of inspection there was no credentialed BCO aboard. COI requires at least (1) one on board at all times. Provide BCO endorsement within 3 months.
Lifesaving › Inflatable Liferafts › Float Free
Issued 23 February 2018
Resolved
Spar is required to have liferafts arranged for float free launching and have an aggregate capacity that will accommodate the total number of persons permitted on board. Of the liferafts on board, only (2) twenty-five man liferafts are currently in a float free arrangement. Provide a plan to D8 OCMI to ensure float free arrangement for liferafts to ensure the total number of persons on board to the satisfaction of USCG marine inspector.
Lifesaving › Lifeboat › Self-contained Air Support System
Issued 23 February 2018
Resolved
Lifeboat’s approved under 46CFR160.035 are required to have a supplied air system. During testing of the supplied air system on all (3) lifeboats, all bottles were below minimum pressure and regulating valves were either inoperable, or set incorrectly. Provide 3rd party servicing report attesting to proper operation of supplied air system to the satisfaction of the USCG Marine Inspector.
Electrical › Electric Supply System (service) › Cable
Issued 29 January 2017
Resolved
Cable to ESS system was found to be lose and caused a facility blackout. Operational control issued.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 29 January 2017
Resolved
Multiple panelboards were found to have incorrect or outdated circuit directories.
Documentation › Safety Management System › Reports and Analysis Procedures
Issued 29 January 2017
Resolved
Facility should provide corrective actions reports stemming from facility blackout that occured on 27JAN2017.
Construction/Loadline › Structures › Superstructure
Issued 1 November 2016
Resolved
Facility is to provide approval letter for new module
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 1 November 2016
Resolved
Numerous fire doors were found to not meet structural fire protection. Repair all fire doors. Extended to 1Feb17-now 1Mar17 final, due to ordered parts availability. [name withheld].
Electrical › Electrical Distribution System (emergency) › Main-emergency Bus Tie
Issued 1 November 2016
Resolved
Facilitys Emmergency BUS had the ability to feed the Aux Bus. Provide documents for this BUS tie in for MSC review.
Electrical › Electric Generation Source (emergency) › Switch
Issued 1 November 2016
Resolved
Emergency generator did not shut down on overspeed trip.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 1 November 2016
Resolved
Facility did not have approved Fuel Oil Transfer Procedurs on board. Extended to 1Jan17. RSM.
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 November 2016
Resolved
Mulitiple cable transits through structural fire boundries were missing.
Lifesaving › Rescue Boat › Carriage Requirement
Issued 1 November 2016
Resolved
Facility could not provide proper documentation for lifeboats as also being certificated as rescue boat under 46 CFR 160.156/54/0
Fire Fighting › Structural - A Class Divisions › Door Frames
Issued 5 February 2016
Resolved
Pantry door hinge is sprung and fire door leaves gap when closed. Repair or replace fire door.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 5 February 2016
Resolved
Estimated quantities of food waste discharged to the sea were not recorded in logs of food waste discharges to the sea. Include food waste discharge quantities in logged discharge entries.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.